Investigations on the Coupling of High-Performance Liquid Chromatography to Direct Analysis in Real Time Mass Spectrometry

被引:58
|
作者
Eberherr, Walter [1 ]
Buchberger, Wolfgang [1 ]
Hertsens, Robert [2 ]
Klampfl, Christian W. [1 ]
机构
[1] Johannes Kepler Univ Linz, Inst Analyt Chem, A-4040 Linz, Austria
[2] JEOL Europe BV, B-1930 Zaventem, Belgium
关键词
ATMOSPHERIC-PRESSURE PHOTOIONIZATION; MICELLAR ELECTROKINETIC CHROMATOGRAPHY; DESORPTION ELECTROSPRAY-IONIZATION; OF-FLIGHT; DRUGS;
D O I
10.1021/ac1008496
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel hyphenated technique namely the combination of HPLC with direct analysis in real time (DART) mass spectrometry (MS) is presented. The coupling of HPLC to DART-MS was achieved by a simple interface design with a capillary end piece transferring the HPLC effluent to the ionization region of the DART. Flow rates (0.3-1.6 mL min(-1)) and inner diameters of the capillary (50-150 mu m) were harmonized to provide a stable liquid jet. Ionization-related parameters optimized included positioning of the capillary end piece with respect to He outlet of the ionization source and the MS inlet, He heater temperature and He flow rate. Among DART-MS voltages, the grid electrode voltage proved to have the most pronounced effect on signal intensities. A major benefit of this setup is the possibility to employ (commonly not MS-compatible) HPLC eluents such as phosphate buffers up to a phosphate concentration of 120 mM even at typical HPLC flow rates such as 1 mL min(-1) and above without negative side effects like contamination of the ion source or ion suppression. Experiments evaluating the correlation of signal intensity to mass-flow and concentration revealed that DART-MS can be seen as a mass flow sensitive detector. The usability of this hyphenated technique has been tested on the example of four parabenes (measured in the negative ion mode) as well as a set of pyrazine derivatives (measured in the positive ion mode). For the parabenes limits of detection (LOD) in the range of 20-55 mu g L-1 and linear ranges from at least 200-10000 mu g L-1 with correlation coefficients better than 0.997 were obtained.
引用
收藏
页码:5792 / 5796
页数:5
相关论文
共 50 条
  • [21] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    VESTAL, ML
    SCIENCE, 1984, 226 (4672) : 275 - 281
  • [22] High-performance liquid chromatography mass spectrometry of steroids (review)
    Mitamura, K
    Shimada, K
    BUNSEKI KAGAKU, 1999, 48 (04) : 401 - 411
  • [23] High-performance liquid chromatography mass spectrometry of epoxy resins
    Fuchslueger, U
    Rissler, K
    Stephan, H
    Grether, HJ
    Grasserbauer, M
    JOURNAL OF APPLIED POLYMER SCIENCE, 1999, 72 (07) : 913 - 925
  • [24] Qualifying high-performance liquid chromatography/mass spectrometry systems
    Duncan, WP
    Pritchett, TJ
    BIOPHARM-THE APPLIED TECHNOLOGIES OF BIOPHARMACEUTICAL DEVELOPMENT, 1999, 12 (10): : 65 - 66
  • [25] Detection of Nε-monomethyllysine using high-performance liquid chromatography and high-performance liquid chromatography-mass spectrometry
    Kalász, H
    Szücs, Z
    Tihanyi, M
    Szilágyi, A
    Lengyel, J
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1079 (1-2) : 208 - 212
  • [26] Monitoring stevioside in soju by high-performance liquid chromatography and liquid chromatography/mass spectrometry
    Ni, Fan
    Ammann, Jeffrey
    Mabud, Abdul
    Journal of AOAC International, 1600, 90 (05): : 1365 - 1372
  • [27] Monitoring stevioside in soju by high-performance liquid chromatography and liquid chromatography/mass spectrometry
    Ni, Fan
    Ammann, Jeffrey
    Mabud, Abdul
    JOURNAL OF AOAC INTERNATIONAL, 2007, 90 (05) : 1365 - 1372
  • [28] Study on the photostability of guaiazulene by high-performance liquid chromatography/mass spectrometry and gas chromatography/mass spectrometry
    Fiori, Jessica
    Gotti, Roberto
    Albini, Angelo
    Cavrini, Vanni
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (17) : 2698 - 2706
  • [29] ANALYSIS OF BENZOYLECGONINE IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND GAS CHROMATOGRAPHY MASS SPECTROMETRY
    GRAFFEO, AP
    LIN, DCK
    FOLTZ, RL
    JOURNAL OF CHROMATOGRAPHY, 1976, 126 (NOV3): : 717 - 722
  • [30] Direct measurement of steroid sulfate and glucuronide conjugates with high-performance liquid chromatography mass spectrometry
    Bowers, LD
    Sanaullah
    JOURNAL OF CHROMATOGRAPHY B, 1996, 687 (01): : 61 - 68