Bioanalysis without Sample Cleanup or Chromatography: The Evaluation and Initial Implementation of Direct Analysis in Real Time Ionization Mass Spectrometry for the Quantification of Drugs in Biological Matrixes

被引:169
|
作者
Yu, Shaoxia [1 ]
Crawford, Elizabeth [2 ]
Tice, Joe [2 ]
Musselman, Brian [2 ]
Wu, Jing-Tao [1 ]
机构
[1] Millennium Pharmaceut Inc, Dept Drug Metab & Pharmacokinet, Cambridge, MA 02139 USA
[2] IonSense Inc, Saugus, MA 01906 USA
关键词
LIQUID-CHROMATOGRAPHY; PLASMA; EXTRACTION; INJECTION; ION;
D O I
10.1021/ac801734t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two key bottlenecks in pharmaceutical bioanalysis are sample cleanup and chromatographic separations. Although multiple approaches have been developed in the past decade to either shorten or multiplex these steps, they remain the rate limiting steps as ADME (Absorption, Distribution, Metabolism, and Excretion) property screening is being routinely incorporated into the drug discovery process. In this work, a novel system incorporating an automated Direct Analysis in Real Time (DART) ionization source coupled with a triple-quadrupole mass spectrometer has been developed and evaluated for quantitative bioanalysis. This system has the capability of directly analyzing samples from their biological matrixes and therefore potentially eliminating the need for sample cleanup and chromatographic separations. A LEAP Technologies autosampler was customized to perform the automated sample introduction into the DART beam with high precision, which significantly improved the reproducibility of the method. Additional pumping was applied to the atmospheric pressure inlet on the mass spectrometer to compensate for the increased vacuum load because of the use of high-flow helium by the DART. This resulted in an improvement of detection sensitivity by a factor of 10 to 100 times. Matrix effects for a diversified class of compounds were evaluated directly from untreated raw plasma and were found to range from approximately 0.05 to 0.7. Precision and accuracy were also tested for multiple test compounds over a dynamic range of four orders of magnitude. The system has been used to analyze biological samples from both in vivo pharmacokinetic studies and in vitro microsomal/S9 stability studies, and the results generated were similar to those obtained with conventional LC/MS/MS methods. Overall, this new automated DART-triple quadrupole mass spectrometer system has demonstrated significant potential for high-throughput bioanalysis.
引用
收藏
页码:193 / 202
页数:10
相关论文
共 50 条
  • [41] Evaluation of QuEChERS, Cartridge SPE Cleanup, and Gas Chromatography Time-of-Flight Mass Spectrometry for the Analysis of Pesticides in Dietary Supplements
    Kowalski, Julie
    Misselwitz, Michelle
    Thomas, Jason
    Cochran, Jack
    LC GC NORTH AMERICA, 2010, 28 (11) : 972 - 977
  • [42] APPLICATION OF PAPER SPRAY IONIZATION MASS SPECTROMETRY AND RELATED TECHNIQUES IN THE DIRECT ANALYSIS OF BIOLOGICAL MATRICES FOR DETECTION OF DRUGS- A REVIEW
    Allochio Filho, Joao Francisco
    Pires, Bruna Carneiro
    Santos, Nayara A.
    Dionisio, Sara Joaquina Inocencio
    Conceicao, Nathalia dos S.
    Feu, Amanda Eiriz
    Borges, Warley de Souza
    Lacerda Jr., Valdemar
    Romao, Wanderson
    QUIMICA NOVA, 2023, 46 (10): : 972 - 982
  • [43] Office Chromatography: Precise printing of sample solutions on miniaturized thin-layer phases and utilization for scanning Direct Analysis in Real Time mass spectrometry
    Haebe, Tim T.
    Morlock, Gertrud E.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1413 : 127 - 134
  • [44] On-line coupling of macroporous resin column chromatography with direct analysis in real time mass spectrometry utilizing a surface flowing mode sample holder
    Zeng, Shanshan
    Wang, Lu
    Chen, Teng
    Qu, Haibin
    ANALYTICA CHIMICA ACTA, 2014, 811 : 43 - 50
  • [45] The coupling of direct analysis in real time ionization to Fourier transform ion cyclotron resonance mass spectrometry for ultrahigh-resolution mass analysis
    Rummel, Julia L.
    McKenna, Amy M.
    Marshall, Alan G.
    Eyler, John R.
    Powell, David H.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (06) : 784 - 790
  • [46] DETERMINATION OF DRUGS AND DRUG-LIKE COMPOUNDS IN DIFFERENT SAMPLES WITH DIRECT ANALYSIS IN REAL TIME MASS SPECTROMETRY
    Chernetsova, Elena S.
    Morlock, Gertrud E.
    MASS SPECTROMETRY REVIEWS, 2011, 30 (05) : 875 - 883
  • [47] Rapid analysis of Δ-9-tetrahydrocannabinol in hair using direct analysis in real time ambient ionization orbitrap mass spectrometry
    Duvivier, Wilco F.
    van Beek, Teris A.
    Pennings, Ed J. M.
    Nielen, Michel W. F.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (07) : 682 - 690
  • [48] Analysis of dimethylamphetamine and its metabolites in human urine by liquid chromatography-electrospray ionization-mass spectrometry with direct sample injection
    Sato, M
    Hida, M
    Nagase, H
    FORENSIC SCIENCE INTERNATIONAL, 2002, 128 (03) : 146 - 154
  • [49] Application of direct analysis in real time (DART) and direct inlet probe (DIP-APCI) mass spectrometry in the context of industrial sample analysis
    Viehbeck, Stefan
    Matysik, Frank-Michael
    MONATSHEFTE FUR CHEMIE, 2016, 147 (08): : 1349 - 1352
  • [50] Application of direct analysis in real time (DART) and direct inlet probe (DIP-APCI) mass spectrometry in the context of industrial sample analysis
    Stefan Viehbeck
    Frank-Michael Matysik
    Monatshefte für Chemie - Chemical Monthly, 2016, 147 : 1349 - 1352