Bioanalysis without Sample Cleanup or Chromatography: The Evaluation and Initial Implementation of Direct Analysis in Real Time Ionization Mass Spectrometry for the Quantification of Drugs in Biological Matrixes

被引:169
|
作者
Yu, Shaoxia [1 ]
Crawford, Elizabeth [2 ]
Tice, Joe [2 ]
Musselman, Brian [2 ]
Wu, Jing-Tao [1 ]
机构
[1] Millennium Pharmaceut Inc, Dept Drug Metab & Pharmacokinet, Cambridge, MA 02139 USA
[2] IonSense Inc, Saugus, MA 01906 USA
关键词
LIQUID-CHROMATOGRAPHY; PLASMA; EXTRACTION; INJECTION; ION;
D O I
10.1021/ac801734t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two key bottlenecks in pharmaceutical bioanalysis are sample cleanup and chromatographic separations. Although multiple approaches have been developed in the past decade to either shorten or multiplex these steps, they remain the rate limiting steps as ADME (Absorption, Distribution, Metabolism, and Excretion) property screening is being routinely incorporated into the drug discovery process. In this work, a novel system incorporating an automated Direct Analysis in Real Time (DART) ionization source coupled with a triple-quadrupole mass spectrometer has been developed and evaluated for quantitative bioanalysis. This system has the capability of directly analyzing samples from their biological matrixes and therefore potentially eliminating the need for sample cleanup and chromatographic separations. A LEAP Technologies autosampler was customized to perform the automated sample introduction into the DART beam with high precision, which significantly improved the reproducibility of the method. Additional pumping was applied to the atmospheric pressure inlet on the mass spectrometer to compensate for the increased vacuum load because of the use of high-flow helium by the DART. This resulted in an improvement of detection sensitivity by a factor of 10 to 100 times. Matrix effects for a diversified class of compounds were evaluated directly from untreated raw plasma and were found to range from approximately 0.05 to 0.7. Precision and accuracy were also tested for multiple test compounds over a dynamic range of four orders of magnitude. The system has been used to analyze biological samples from both in vivo pharmacokinetic studies and in vitro microsomal/S9 stability studies, and the results generated were similar to those obtained with conventional LC/MS/MS methods. Overall, this new automated DART-triple quadrupole mass spectrometer system has demonstrated significant potential for high-throughput bioanalysis.
引用
收藏
页码:193 / 202
页数:10
相关论文
共 50 条
  • [31] Analysis of isoflavones in soybeans employing direct analysis in real-time ionization-high-resolution mass spectrometry
    Lojza, Jaromir
    Cajka, Tomas
    Schulzova, Vera
    Riddellova, Katerina
    Hajslova, Jana
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (03) : 476 - 481
  • [32] Trace detection and competitive ionization of erythritol tetranitrate in mixtures using direct analysis in real time mass spectrometry
    Forbes, Thomas P.
    Sisco, Edward
    ANALYTICAL METHODS, 2015, 7 (08) : 3632 - 3636
  • [33] Selective ionization of melamine in powdered milk by using argon direct analysis in real time (DART) mass spectrometry
    Dane, A. John
    Cody, Robert B.
    ANALYST, 2010, 135 (04) : 696 - 699
  • [34] Evaluation of direct analysis in real time mass spectrometry for onsite monitoring of batch slurry reactions
    Cho, David S.
    Gibson, Stephen C.
    Bhandari, Deepak
    McNally, Mary Ellen
    Hoffman, Ron M.
    Cook, Kelsey D.
    Song, Liguo
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (23) : 3575 - 3580
  • [35] Detection of illicit drugs on surfaces using direct analysis in real time (DART) time-of-flight mass spectrometry
    Grange, Andrew H.
    Sovocool, G. Wayne
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (09) : 1271 - 1281
  • [36] Determination of trichothecenes in wheat grain without sample cleanup using comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry
    Jelen, Henryk H.
    Wasowicz, Erwin
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1215 (1-2) : 203 - 207
  • [37] Quantification of artificial sweeteners in alcoholic drinks using direct analysis in real-time QTRAP mass spectrometry
    Li, Xiaomin
    Li, Shuangqing
    Li, Hongmei
    Wang, Jing
    Luo, Qin
    Yin, Xiong
    FOOD CHEMISTRY, 2021, 342 (342)
  • [38] Surface desorption atmospheric pressure chemical ionization mass spectrometry for direct ambient sample analysis without toxic chemical contamination
    Chen, Huanwen
    Zheng, Jian
    Zhang, Xie
    Luo, Mingbiao
    Wang, Zhichang
    Qiao, Xiaolin
    JOURNAL OF MASS SPECTROMETRY, 2007, 42 (08): : 1045 - 1056
  • [39] Rapid quality control of black truffles using Direct Analysis in Real Time Mass Spectrometry and Hydrophilic Interaction Liquid Chromatography Mass Spectrometry
    Losso, Klemens
    Woerz, Hannah
    Kappacher, Christoph
    Huber, Susanne
    Jakschitz, Thomas
    Rainer, Matthias
    Bonn, Guenther K.
    FOOD CHEMISTRY, 2023, 403
  • [40] Direct bioautography hyphenated to direct analysis in real time mass spectrometry: Chromatographic separation, bioassay and mass spectra, all in the same sample run
    Haebe, Tim T.
    Jamshidi-Aidji, Maryam
    Macho, Jennifer
    Morlock, Gertrud E.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1568 : 188 - 196