Bioanalysis without Sample Cleanup or Chromatography: The Evaluation and Initial Implementation of Direct Analysis in Real Time Ionization Mass Spectrometry for the Quantification of Drugs in Biological Matrixes

被引:169
|
作者
Yu, Shaoxia [1 ]
Crawford, Elizabeth [2 ]
Tice, Joe [2 ]
Musselman, Brian [2 ]
Wu, Jing-Tao [1 ]
机构
[1] Millennium Pharmaceut Inc, Dept Drug Metab & Pharmacokinet, Cambridge, MA 02139 USA
[2] IonSense Inc, Saugus, MA 01906 USA
关键词
LIQUID-CHROMATOGRAPHY; PLASMA; EXTRACTION; INJECTION; ION;
D O I
10.1021/ac801734t
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two key bottlenecks in pharmaceutical bioanalysis are sample cleanup and chromatographic separations. Although multiple approaches have been developed in the past decade to either shorten or multiplex these steps, they remain the rate limiting steps as ADME (Absorption, Distribution, Metabolism, and Excretion) property screening is being routinely incorporated into the drug discovery process. In this work, a novel system incorporating an automated Direct Analysis in Real Time (DART) ionization source coupled with a triple-quadrupole mass spectrometer has been developed and evaluated for quantitative bioanalysis. This system has the capability of directly analyzing samples from their biological matrixes and therefore potentially eliminating the need for sample cleanup and chromatographic separations. A LEAP Technologies autosampler was customized to perform the automated sample introduction into the DART beam with high precision, which significantly improved the reproducibility of the method. Additional pumping was applied to the atmospheric pressure inlet on the mass spectrometer to compensate for the increased vacuum load because of the use of high-flow helium by the DART. This resulted in an improvement of detection sensitivity by a factor of 10 to 100 times. Matrix effects for a diversified class of compounds were evaluated directly from untreated raw plasma and were found to range from approximately 0.05 to 0.7. Precision and accuracy were also tested for multiple test compounds over a dynamic range of four orders of magnitude. The system has been used to analyze biological samples from both in vivo pharmacokinetic studies and in vitro microsomal/S9 stability studies, and the results generated were similar to those obtained with conventional LC/MS/MS methods. Overall, this new automated DART-triple quadrupole mass spectrometer system has demonstrated significant potential for high-throughput bioanalysis.
引用
收藏
页码:193 / 202
页数:10
相关论文
共 50 条
  • [1] Implementation of an enclosed ionization interface for the analysis of liquid sample streams with direct analysis in real time mass spectrometry
    Kloth, Ricarda
    Khanipour, Peyman
    Mayrhofer, Karl J. J.
    Katsounaros, Ioannis
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (13)
  • [2] Comprehensive comparison of ambient mass spectrometry with desorption electrospray ionization and direct analysis in real time for direct sample analysis
    Li, Lei
    Wang, Qiqin
    Li, Wen
    Yao, Ya-Nan
    Wu, Lin
    Hu, Bin
    TALANTA, 2019, 203 : 140 - 146
  • [3] Quantification of small molecules in plasma with direct analysis in real time tandem mass spectrometry, without sample preparation and liquid chromatographic separation
    Zhao, Yeping
    Lam, Michelle
    Wu, Danlin
    Mak, Rowena
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (20) : 3217 - 3224
  • [4] Coupling of planar chromatography with Direct Analysis in Real Time mass spectrometry
    Morlock, Gertrud E.
    Chernetsova, Elena S.
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (03): : 703 - 710
  • [5] Ionization characteristics of amino acids in direct analysis in real time mass spectrometry
    Sekimoto, Kanako
    Sakakura, Motoshi
    Kawamukai, Takatomo
    Hike, Hiroshi
    Shiota, Teruhisa
    Usui, Fumihiko
    Bando, Yasuhiko
    Takayama, Mitsuo
    ANALYST, 2014, 139 (10) : 2589 - 2599
  • [6] New coupling of planar chromatography with direct analysis in real time mass spectrometry
    Morlock, Gertrud
    Ueda, Yoshihisa
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) : 243 - 251
  • [7] Effect of reducing sample volume on the detection of drugs in urine by transmission mode direct analysis in real time mass spectrometry
    Liang, Paul
    Li, Frederick
    Laramee, Brittany
    Musselman, Brian
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35
  • [8] ANALYSIS OF GETING BITUMINOUS COAL BY ELECTROSPRAY IONIZATION AND DIRECT ANALYSIS IN REAL TIME MASS SPECTROMETRY
    Fan, Xing
    Chen, Lu
    Wang, Shou-Ze
    Qing, Yu
    Wei, Xian-Yong
    Zhao, Yun-Peng
    Zheng, Ai-Li
    Zhu, Ji-Liang
    You, Chun-Yan
    ANALYTICAL LETTERS, 2014, 47 (12) : 2012 - 2022
  • [9] The evaluation and implementation of direct analysis in real time quadrupole time-of-flight tandem mass spectrometry for characterization and quantification of geniposide in Re Du Ning Injections
    Li, Yan-Jing
    Wang, Zhen-Zhong
    Bi, Yu-An
    Ding, Gang
    Sheng, Long-Sheng
    Qin, Jian-Ping
    Xiao, Wei
    Li, Jia-Chun
    Wang, Yong-Xiang
    Wang, Xue
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2012, 26 (11) : 1377 - 1384
  • [10] Rapid quantification of cannabidiol from oils by direct analysis in real time mass spectrometry
    Huber, Susanne
    Losso, Klemens
    Bonn, Gunther K.
    Rainer, Matthias
    ANALYTICAL METHODS, 2022, 14 (39) : 3875 - 3880