Implementation of an enclosed ionization interface for the analysis of liquid sample streams with direct analysis in real time mass spectrometry

被引:7
|
作者
Kloth, Ricarda [1 ,2 ]
Khanipour, Peyman [1 ,2 ]
Mayrhofer, Karl J. J. [1 ,2 ]
Katsounaros, Ioannis [1 ]
机构
[1] Forschungszentrum Julich, Helmholtz Inst Erlangen Nurnberg Renewable Energy, Egerlandstr 3, D-91058 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg, Dept Chem & Biol Engn, Egerlandstr 3, D-91058 Erlangen, Germany
关键词
ION-SOURCE; NONPOLAR COMPOUNDS; CHROMATOGRAPHY; ALCOHOLS; MS;
D O I
10.1002/rcm.9091
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Rationale The development of an interface to analyze liquid sample streams with direct analysis in real time mass spectrometry (DART-MS) is of great interest for coupling various analytical techniques, using non-volatile salts, with MS. Therefore, we devised an enclosed ionization interface and a sample introduction system for the versatile analysis of liquid samples with DART-MS. Methods The sample introduction system consists of a nebulizer, a spray chamber and a transfer line, while the confined ionization interface is created by implementing a cross-shaped housing between ion source outlet and mass spectrometer inlet. Methodical studies of the effects of various setup parameters on signal intensity and peak shape were conducted, while its diverse applicability was demonstrated by coupling with high-performance liquid chromatography (HPLC) for the analysis of alcohols, organic acids and furanic compounds. Results The confinement of the ionization interface results in a robust setup design with a well-defined ionization region for focusing of the sprayed sample mist. Thereby, an increase in analyte signal intensity by three orders of magnitude and improved signal stability and reproducibility were obtained in comparison with a similar open ionization interface configuration. Additionally, the successful quantification of alcohols could be demonstrated as well as the compatibility of the setup with HPLC gradient elution. Conclusions A versatile setup design for the analysis of liquid sample streams with DART-MS was devised for monitoring reactions or hyphenating analytics with MS. The design minimizes interferences from the laboratory surroundings as well as allows for safe handling of hazardous and toxic chemicals, which renders it suitable for a broad range of applications.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Comprehensive comparison of ambient mass spectrometry with desorption electrospray ionization and direct analysis in real time for direct sample analysis
    Li, Lei
    Wang, Qiqin
    Li, Wen
    Yao, Ya-Nan
    Wu, Lin
    Hu, Bin
    TALANTA, 2019, 203 : 140 - 146
  • [2] Ionization characteristics of amino acids in direct analysis in real time mass spectrometry
    Sekimoto, Kanako
    Sakakura, Motoshi
    Kawamukai, Takatomo
    Hike, Hiroshi
    Shiota, Teruhisa
    Usui, Fumihiko
    Bando, Yasuhiko
    Takayama, Mitsuo
    ANALYST, 2014, 139 (10) : 2589 - 2599
  • [3] ANALYSIS OF GETING BITUMINOUS COAL BY ELECTROSPRAY IONIZATION AND DIRECT ANALYSIS IN REAL TIME MASS SPECTROMETRY
    Fan, Xing
    Chen, Lu
    Wang, Shou-Ze
    Qing, Yu
    Wei, Xian-Yong
    Zhao, Yun-Peng
    Zheng, Ai-Li
    Zhu, Ji-Liang
    You, Chun-Yan
    ANALYTICAL LETTERS, 2014, 47 (12) : 2012 - 2022
  • [4] Analysis of anabolic androgenic steroids by direct analysis in real time ionization with time-of-flight mass spectrometry
    Prokudina, E. A.
    Prchalova, J.
    Vysatova, E.
    Kuchar, M.
    Rajchl, A.
    Lapcik, O.
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 392 : 28 - 33
  • [5] Bioanalysis without Sample Cleanup or Chromatography: The Evaluation and Initial Implementation of Direct Analysis in Real Time Ionization Mass Spectrometry for the Quantification of Drugs in Biological Matrixes
    Yu, Shaoxia
    Crawford, Elizabeth
    Tice, Joe
    Musselman, Brian
    Wu, Jing-Tao
    ANALYTICAL CHEMISTRY, 2009, 81 (01) : 193 - 202
  • [6] Vibrating tip spray ionization mass spectrometry for direct sample analysis
    Yao, Ya-Nan
    Wu, Lin
    Di, Dandan
    Yuan, Zi-Cheng
    Hu, Bin
    JOURNAL OF MASS SPECTROMETRY, 2019, 54 (09): : 772 - 779
  • [7] Ionization characteristics of glycosides by direct analysis in real time quadrupole-time of flight mass spectrometry
    Yang, Hongmei
    Gao, Ge
    Wang, Yihan
    Liu, Jinrong
    Li, Zongjun
    Su, Rui
    Wang, Bing
    Lian, Wenhui
    Guod, Xinhua
    Liu, Shuying
    NEW JOURNAL OF CHEMISTRY, 2017, 41 (03) : 1103 - 1109
  • [8] Rapid fingerprint analysis for herbal polysaccharides using direct analysis in real-time ionization mass spectrometry
    Wang, Xing
    Jiang, Qing
    Li, Hongli
    Chen, David D. Y.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (16)
  • [9] Direct sample analysis/time-of-fiight mass spectrometry
    1600, International Scientific Communications Inc. (46):
  • [10] Direct Sample Analysis/Time-of-Flight Mass Spectrometry
    Tyler, Andrew
    Dalmia, Avinash
    AMERICAN LABORATORY, 2014, 46 (01) : 38 - 40