Effective and High-Throughput Analytical Methodology for the Determination of Lead and Cadmium in Water Samples by Disposable Pipette Extraction Coupled with High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS GF AAS)

被引:22
|
作者
Cadorim, Heloisa R. [1 ]
Schneider, Mauana [1 ]
Hinz, Julia [1 ]
Luvizon, Fabiana [1 ]
Dias, Adriana N. [2 ]
Carasek, Eduardo [1 ]
Welz, Bernhard [1 ,3 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Inst Fed Catarinense, Brusque, Brazil
[3] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
关键词
Cadmium; cork; disposable pipette tip extraction; high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS); lead; preconcentration; SOLID-PHASE EXTRACTION; HEAVY-METALS; CARBON NANOTUBES; CORK BIOMASS; MICROEXTRACTION; BIOSORPTION; CHROMIUM; PRECONCENTRATION; COPRECIPITATION; BIOSORBENT;
D O I
10.1080/00032719.2019.1596117
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new procedure for the preconcentration of trace amounts of free Pb and Cd by disposable pipette extraction (DPX) is proposed herein. Recycled cork is used as a biosorbent and the procedure is completely free of organic solvents. The cork was reduced to a powder and characterized by scanning electron microscopy. Several parameters that influence the preconcentration of Pb and Cd with DPX-cork, such as the sample pH, number of extraction cycles, biosorbent mass, and percentage of acid in the desorption step, were studied. The tolerance of DPX-cork with respect to 10 potential interfering ions was also evaluated. Coupled with the high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) technique, the sample preparation method allowed the analytical limits required for quality control (according to the permitted limits established by legislation) to be obtained. The limits of detection for the extraction of a 3.5-mL water sample were 200 ng L-1 for Pb and 100 ng L-1 for Cd. The relative standard deviations were around 7.5% for Pb and 8.0% for Cd. The optimized method was successfully applied to the determination of Cd and Pb in two certified reference materials (water and wastewater) and five water samples (collected from a mangrove, a creek, and the sea).
引用
收藏
页码:2133 / 2149
页数:17
相关论文
共 50 条
  • [41] Sequential and simultaneous determination of chlorine, iron, and silicon in beer samples by high-resolution continuum source graphite furnace molecular and atomic absorption spectrometry
    Pires, Lais N.
    Almeida, Jorge S.
    Dias, Fabio de S.
    Teixeira, Leonardo S. G.
    FOOD ANALYTICAL METHODS, 2020, 13 (09) : 1746 - 1754
  • [42] Fast sequential determination of manganese and chromium in vegetable oil and biodiesel samples by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Almeida, Jorge S.
    Brandao, Geovani C.
    dos Santos, Gabriel L.
    Teixeira, Leonardo S. G.
    ANALYTICAL METHODS, 2016, 8 (15) : 3249 - 3254
  • [43] Sequential and simultaneous determination of chlorine, iron, and silicon in beer samples by high-resolution continuum source graphite furnace molecular and atomic absorption spectrometry
    Laís N. Pires
    Jorge S. Almeida
    Fabio de S. Dias
    Leonardo S. G. Teixeira
    Food Analytical Methods, 2020, 13 : 1746 - 1754
  • [44] Determination of selenium in soil samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Castilho, Ivan N. B.
    Pereira, Ederson R.
    Welz, Bernhard
    Shaltout, Abdallah A.
    Caraseka, Eduardo
    Martensd, Irland B. Gonzaga
    ANALYTICAL METHODS, 2014, 6 (09) : 2870 - 2875
  • [45] New analytical method for total fluorine determination in soil samples using high-resolution continuum source graphite furnace molecular absorption spectrometry
    Boschetti, Wiliam
    Dessuy, Morgana B.
    Pizzato, Antonio H.
    Vale, Maria Goreti R.
    MICROCHEMICAL JOURNAL, 2017, 130 : 276 - 280
  • [46] Determination of Lead in Eye Shadow and Blush by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry Employing Direct Solid Sampling
    Barros, Ariane I.
    Silva, Tiago V.
    Ferreira, Edilene C.
    Gomes Neto, Jose A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (01) : 140 - 146
  • [47] Direct solid sampling determination of lead in cheese varieties by high resolution continuum source graphite furnace atomic absorption spectrometry
    Tinas, Hande
    Ozbek, Nil
    Akman, Suleyman
    ANALYTICAL METHODS, 2017, 9 (45) : 6365 - 6370
  • [48] Determination of Lead, Cadmium, Copper, and Nickel in the Tonghui River of Beijing, China, by Cloud Point Extraction-High Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Ren, Ting
    Zhao, Li-Jiao
    Sun, Bo-Si
    Zhong, Ru-Gang
    JOURNAL OF ENVIRONMENTAL QUALITY, 2013, 42 (06) : 1752 - 1762
  • [49] Fast arsenic speciation in water by on-site solid phase extraction and high-resolution continuum source graphite furnace atomic absorption spectrometry
    Mihucz, Victor G.
    Bencs, Laszlo
    Koncz, Kornel
    Tatar, Enika
    Weiszburg, Tamas
    Zaray, Gyula
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 128 : 30 - 35
  • [50] Determination of Chlorine in Milk via Molecular Absorption of SrCI Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Ozbek, Nil
    Akman, Suleyman
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2016, 64 (28) : 5767 - 5772