Effective and High-Throughput Analytical Methodology for the Determination of Lead and Cadmium in Water Samples by Disposable Pipette Extraction Coupled with High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS GF AAS)

被引:22
|
作者
Cadorim, Heloisa R. [1 ]
Schneider, Mauana [1 ]
Hinz, Julia [1 ]
Luvizon, Fabiana [1 ]
Dias, Adriana N. [2 ]
Carasek, Eduardo [1 ]
Welz, Bernhard [1 ,3 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Inst Fed Catarinense, Brusque, Brazil
[3] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
关键词
Cadmium; cork; disposable pipette tip extraction; high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS); lead; preconcentration; SOLID-PHASE EXTRACTION; HEAVY-METALS; CARBON NANOTUBES; CORK BIOMASS; MICROEXTRACTION; BIOSORPTION; CHROMIUM; PRECONCENTRATION; COPRECIPITATION; BIOSORBENT;
D O I
10.1080/00032719.2019.1596117
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new procedure for the preconcentration of trace amounts of free Pb and Cd by disposable pipette extraction (DPX) is proposed herein. Recycled cork is used as a biosorbent and the procedure is completely free of organic solvents. The cork was reduced to a powder and characterized by scanning electron microscopy. Several parameters that influence the preconcentration of Pb and Cd with DPX-cork, such as the sample pH, number of extraction cycles, biosorbent mass, and percentage of acid in the desorption step, were studied. The tolerance of DPX-cork with respect to 10 potential interfering ions was also evaluated. Coupled with the high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) technique, the sample preparation method allowed the analytical limits required for quality control (according to the permitted limits established by legislation) to be obtained. The limits of detection for the extraction of a 3.5-mL water sample were 200 ng L-1 for Pb and 100 ng L-1 for Cd. The relative standard deviations were around 7.5% for Pb and 8.0% for Cd. The optimized method was successfully applied to the determination of Cd and Pb in two certified reference materials (water and wastewater) and five water samples (collected from a mangrove, a creek, and the sea).
引用
收藏
页码:2133 / 2149
页数:17
相关论文
共 50 条
  • [21] Determination of Cu and Mn in Seawater by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Burylin, Mikhail Yu
    Kopeyko, Elena S.
    Bauer, Viktoriya A.
    ANALYTICAL LETTERS, 2022, 55 (10) : 1663 - 1671
  • [22] Use of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS) for Sequential Multi-Element Determination of Metals in Seawater and Wastewater Samples
    E. Peña-Vázquez
    M. C. Barciela-Alonso
    C. Pita-Calvo
    R. Domínguez-González
    P. Bermejo-Barrera
    Journal of Applied Spectroscopy, 2015, 82 : 681 - 686
  • [23] Determination of Silver in Environmental Samples by High-resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry after Preconcentration on Bentonite
    Magdalena Krawczyk-Coda
    Journal of Analytical Chemistry, 2022, 77 : 1155 - 1161
  • [24] Determination of Silver in Environmental Samples by High-resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry after Preconcentration on Bentonite
    Krawczyk-Coda, Magdalena
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (09) : 1155 - 1161
  • [25] Determination of Pb and Cr in sunscreen samples by high-resolution continuum source graphite furnace atomic absorption spectrometry and direct analysis
    Zmozinski, Ariane V.
    Pretto, Tatiane
    Borges, Aline R.
    Duarte, Alvaro T.
    Vale, Maria Goreti R.
    MICROCHEMICAL JOURNAL, 2016, 128 : 89 - 94
  • [26] Determination of lead in coal using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry
    Gallindo Borges, DL
    da Silva, AF
    Curtius, AJ
    Welz, B
    Heitmann, U
    MICROCHIMICA ACTA, 2006, 154 (1-2) : 101 - 107
  • [27] Determination of Lead in Coal Using Direct Solid Sampling and High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Daniel L. Gallindo Borges
    Alessandra Furtado da Silva
    Adilson José Curtius
    Bernhard Welz
    Uwe Heitmann
    Microchimica Acta, 2006, 154 : 101 - 107
  • [28] Use of High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS) for Sequential Multi-Element Determination of Metals in Seawater and Wastewater Samples
    Pena-Vazquez, E.
    Barciela-Alonso, M. C.
    Pita-Calvo, C.
    Dominguez-Gonzalez, R.
    Bermejo-Barrera, P.
    JOURNAL OF APPLIED SPECTROSCOPY, 2015, 82 (04) : 681 - 686
  • [29] High-resolution continuum source flame atomic absorption spectrometric (HR-CS FAAS) determination of trace aluminium and lead in water and some beverage samples after separation and preconcentration procedure
    Ciftci, Harun
    Er, Cigdem
    Yalcinkaya, Ozcan
    Temuz, M. Mursit
    Turker, Ali Rehber
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2014, 94 (06) : 579 - 593
  • [30] Determination of heavy metals in cigarettes using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Ren, Ting
    Chen, Xi
    Ge, Yao
    Zhao, Lijiao
    Zhong, Rugang
    ANALYTICAL METHODS, 2017, 9 (27) : 4033 - 4043