Effective and High-Throughput Analytical Methodology for the Determination of Lead and Cadmium in Water Samples by Disposable Pipette Extraction Coupled with High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS GF AAS)

被引:22
|
作者
Cadorim, Heloisa R. [1 ]
Schneider, Mauana [1 ]
Hinz, Julia [1 ]
Luvizon, Fabiana [1 ]
Dias, Adriana N. [2 ]
Carasek, Eduardo [1 ]
Welz, Bernhard [1 ,3 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Inst Fed Catarinense, Brusque, Brazil
[3] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
关键词
Cadmium; cork; disposable pipette tip extraction; high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS); lead; preconcentration; SOLID-PHASE EXTRACTION; HEAVY-METALS; CARBON NANOTUBES; CORK BIOMASS; MICROEXTRACTION; BIOSORPTION; CHROMIUM; PRECONCENTRATION; COPRECIPITATION; BIOSORBENT;
D O I
10.1080/00032719.2019.1596117
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new procedure for the preconcentration of trace amounts of free Pb and Cd by disposable pipette extraction (DPX) is proposed herein. Recycled cork is used as a biosorbent and the procedure is completely free of organic solvents. The cork was reduced to a powder and characterized by scanning electron microscopy. Several parameters that influence the preconcentration of Pb and Cd with DPX-cork, such as the sample pH, number of extraction cycles, biosorbent mass, and percentage of acid in the desorption step, were studied. The tolerance of DPX-cork with respect to 10 potential interfering ions was also evaluated. Coupled with the high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) technique, the sample preparation method allowed the analytical limits required for quality control (according to the permitted limits established by legislation) to be obtained. The limits of detection for the extraction of a 3.5-mL water sample were 200 ng L-1 for Pb and 100 ng L-1 for Cd. The relative standard deviations were around 7.5% for Pb and 8.0% for Cd. The optimized method was successfully applied to the determination of Cd and Pb in two certified reference materials (water and wastewater) and five water samples (collected from a mangrove, a creek, and the sea).
引用
收藏
页码:2133 / 2149
页数:17
相关论文
共 50 条
  • [31] Simultaneous determination of cadmium, iron and tin in canned foods using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Leao, Danilo J.
    Junior, Mario M. S.
    Brandao, Geovani C.
    Ferreira, Sergio L. C.
    TALANTA, 2016, 153 : 45 - 50
  • [32] Method development for the determination of cadmium in lipsticks directly by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
    Tinas, Hande
    Ozbek, Nil
    Akman, Suleyman
    MICROCHEMICAL JOURNAL, 2018, 138 : 316 - 320
  • [33] Simultaneous and direct determination of iron and nickel in biological solid samples by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Gomez-Nieto, Beatriz
    Jesus Gismera, Ma
    Teresa Sevilla, Ma
    Procopio, Jesus R.
    TALANTA, 2013, 116 : 860 - 865
  • [34] Determination of lead in dietary supplements by high-resolution continuum-source graphite furnace atomic absorption spectrometry with direct solid sampling
    Leal, Gabriela Camera
    Mattiazzi, Patricia
    Rovasi, Franciele
    Dal Molin, Thais
    Bohrer, Denise
    do Nascimento, Paulo Cicero
    de Carvalho, Leandro M.
    Viana, Carine
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2020, 86
  • [35] Determination of lead in medicinal plants by high-resolution continuum source graphite furnace atomic absorption spectrometry using direct solid sampling
    Rego, Jardes Figueredo
    Virgilio, Alex
    Nobrega, Joaquim A.
    Gomes Neto, Jose A.
    TALANTA, 2012, 100 : 21 - 26
  • [36] Application of High Resolution-Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS): Determination of trace elements in tea and tisanes
    Paz-Rodriguez, Beatriz
    Raquel Dominguez-Gonzalez, Maria
    Aboal-Somoza, Manuel
    Bermejo-Barrera, Pilar
    FOOD CHEMISTRY, 2015, 170 : 492 - 500
  • [37] Determination of Polyorganosiloxanes (by Silicon) in Water by Extraction High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    Shtin, T. N.
    Gurvich, V. B.
    Galasheva, O. E.
    Shelomentsev, I. G.
    Neudachina, L. K.
    Shtin, S. A.
    INORGANIC MATERIALS, 2023, 59 (14) : 1387 - 1395
  • [38] Determination of Polyorganosiloxanes (by Silicon) in Water by Extraction High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    T. N. Shtin
    V. B. Gurvich
    O. E. Galasheva
    I. G. Shelomentsev
    L. K. Neudachina
    S. A. Shtin
    Inorganic Materials, 2023, 59 : 1387 - 1395
  • [39] Determination of silicon and aluminum in silicon carbide nanocrystals by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Dravecz, Gabriella
    Bencs, Laszlo
    Beke, David
    Gali, Adam
    TALANTA, 2016, 147 : 271 - 275
  • [40] Sequential and simultaneous determination of four elements in soil samples using high-resolution continuum source graphite furnace atomic and molecular absorption spectrometry
    Boschetti, W.
    Orlando, M.
    Dullius, M.
    Dessuy, M. B.
    Vale, M. G. R.
    Welz, B.
    de Andrade, J. B.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (06) : 1269 - 1277