Effective and High-Throughput Analytical Methodology for the Determination of Lead and Cadmium in Water Samples by Disposable Pipette Extraction Coupled with High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS GF AAS)

被引:22
|
作者
Cadorim, Heloisa R. [1 ]
Schneider, Mauana [1 ]
Hinz, Julia [1 ]
Luvizon, Fabiana [1 ]
Dias, Adriana N. [2 ]
Carasek, Eduardo [1 ]
Welz, Bernhard [1 ,3 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, BR-88040900 Florianopolis, SC, Brazil
[2] Inst Fed Catarinense, Brusque, Brazil
[3] Univ Fed Bahia, Inst Nacl Ciencia & Tecnol, CNPq, INCT Energia & Ambiente, Salvador, BA, Brazil
关键词
Cadmium; cork; disposable pipette tip extraction; high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS); lead; preconcentration; SOLID-PHASE EXTRACTION; HEAVY-METALS; CARBON NANOTUBES; CORK BIOMASS; MICROEXTRACTION; BIOSORPTION; CHROMIUM; PRECONCENTRATION; COPRECIPITATION; BIOSORBENT;
D O I
10.1080/00032719.2019.1596117
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new procedure for the preconcentration of trace amounts of free Pb and Cd by disposable pipette extraction (DPX) is proposed herein. Recycled cork is used as a biosorbent and the procedure is completely free of organic solvents. The cork was reduced to a powder and characterized by scanning electron microscopy. Several parameters that influence the preconcentration of Pb and Cd with DPX-cork, such as the sample pH, number of extraction cycles, biosorbent mass, and percentage of acid in the desorption step, were studied. The tolerance of DPX-cork with respect to 10 potential interfering ions was also evaluated. Coupled with the high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) technique, the sample preparation method allowed the analytical limits required for quality control (according to the permitted limits established by legislation) to be obtained. The limits of detection for the extraction of a 3.5-mL water sample were 200 ng L-1 for Pb and 100 ng L-1 for Cd. The relative standard deviations were around 7.5% for Pb and 8.0% for Cd. The optimized method was successfully applied to the determination of Cd and Pb in two certified reference materials (water and wastewater) and five water samples (collected from a mangrove, a creek, and the sea).
引用
收藏
页码:2133 / 2149
页数:17
相关论文
共 50 条
  • [1] Determination of Cd and Cr in tannin samples by high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample sequential analysis (HR-CS SS-GF AAS)
    Zmozinski, Ariane V.
    Pretto, Tatiane
    Borges, Aline R.
    Vale, Maria Goreti R.
    ANALYTICAL METHODS, 2015, 7 (09) : 3735 - 3741
  • [2] Application of Disposable Pipette Extraction for Determination of Yb by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry Using Lanthanum as a Chemical Modifier
    Betiolo, Diogo M.
    Cadorim, Heloisa R.
    Carasek, Eduardo
    Maranhao, Tatiane A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2023, 34 (08) : 1087 - 1099
  • [3] Screening method for extractable organically bound fluorine (EOF) in river water samples by means of high-resolution–continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS)
    Matthias Metzger
    Philip Ley
    Manfred Sturm
    Björn Meermann
    Analytical and Bioanalytical Chemistry, 2019, 411 : 4647 - 4660
  • [4] Elemental Analysis of Pharmaceutical Products for Chronic Kidney Disease by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS GFAAS)
    Maziero, Maiara
    Adolfo, Franciele Rovasi
    Camera Leal, Gabriela
    de Carvalho, Leandro Machado
    Nascimento, Paulo Cicero do
    Viana, Carine
    ANALYTICAL LETTERS, 2022, 55 (01) : 109 - 122
  • [5] Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling
    Borges, Daniel L. Gallindo
    da Silva, Alessandra Furtado
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (08) : 763 - 769
  • [6] Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling
    Borges, Daniel L. Gallindo
    Da Silva, Alessandra Furtado
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    Journal of Analytical Atomic Spectrometry, 2006, 21 (08): : 763 - 769
  • [7] Determination of germanium in plant and soil samples using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) with solid sampling
    Schreiter, Norbert
    Wiche, Oliver
    Aubel, Ines
    Roode-Gutzmer, Quirina
    Bertau, Martin
    JOURNAL OF GEOCHEMICAL EXPLORATION, 2021, 220
  • [8] Determination of Cadmium in Water Samples by Automated Flow-Batch Cloud Point Extraction (CPE) Hyphenated to High-Resolution Continuum Source Flame Atomic Spectrometry (HR-CS FAAS)
    Akiba, Naomi
    Mancini, Rodrigo S. N.
    Carvalho, Alexandre Zatkovskis
    Gaubeur, Ivanise
    ANALYTICAL LETTERS, 2022, 55 (05) : 741 - 754
  • [9] Sequential determination of cadmium and lead in organic pharmaceutical formulations using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Aleluia, Augusto C. M.
    de Santana, Fernanda A.
    Brandao, Geovani C.
    Ferreira, Sergio L. C.
    MICROCHEMICAL JOURNAL, 2017, 130 : 157 - 161
  • [10] Solid-phase extraction and separation procedure for trace aluminum in water samples and its determination by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS)
    Harun Ciftci
    Cigdem Er
    Environmental Monitoring and Assessment, 2013, 185 : 2745 - 2753