Technical Note: CT calibration for proton treatment planning by cross-calibration with proton CT data

被引:7
|
作者
Farace, Paolo [1 ,2 ]
Tommasino, Francesco [2 ,3 ]
Righetto, Roberto [1 ,2 ]
Fracchiolla, Francesco [1 ,2 ]
Scaringella, Monica [4 ,5 ]
Bruzzi, Mara [4 ]
Civinini, Carlo [4 ]
机构
[1] Hosp Trento, Protontherapy Unit, Azienda Prov & Serv Sanit APSS, Trento, Italy
[2] Ist Nazl Fis Nucl TIFPA, Via Sommar 14, Trento, Italy
[3] Univ Trento, Dept Phys, Via Sommar 14, Trento, Italy
[4] Ist Nazl Fis Nucl, Sez Firenze, Via G Sansone 1, Sesto Fiorentino, Italy
[5] Univ Firenze, Dipartimento Fis & Astron, Via G Sansone 1, Sesto Fiorentino, Italy
关键词
CT; proton CT; proton therapy;
D O I
10.1002/mp.14698
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose This study explores the possibility of a new method for x-ray computed tomography (CT) calibration by means of cross-calibration with proton CT (pCT) data. The proposed method aims at a more accurate conversion of CT Hounsfield Units (HU) into proton stopping power ratio (SPR) relative to water to be used in proton-therapy treatment planning. Methods X-ray CT scan was acquired on a synthetic anthropomorphic phantom, composed of different tissue equivalent materials (TEMs). A pCT apparatus was instead adopted to obtain a reference three-dimensional distribution of the phantom's SPR values. After rigid registration, the x-ray CT was artificially blurred to the same resolution of pCT. Then a scatter plot showing voxel-by-voxel SPR values as a function of HU was employed to link the two measurements and thus obtaining a cross-calibrated x-ray CT calibration curve. The cross-calibration was tested at treatment planning system and then compared with a conventional calibration based on exactly the same TEMs constituting the anthropomorphic phantom. Results Cross-calibration provided an accurate SPR mapping, better than by conventional TEMs calibration. The dose distribution of single beams optimized on the reference SPR map was recomputed on cross-calibrated CT, showing, with respect to conventional calibration, minor deviation at the dose fall-off (lower than 1%). Conclusions The presented data demonstrated that, by means of reference pCT data, a heterogeneous phantom can be used for CT calibration, paving the way to the use of biological samples, with their accurate description of patients' tissues. This overcomes the limitations of conventional CT calibration requiring homogenous samples, only available by synthetic TEMs, which fail in accurately mimicking the properties of biological tissues. Once a heterogeneous biological sample is provided with its corresponding reference SPR maps, a cross-calibration procedure could be adopted by other PT centers, even when not equipped with a pCT system.
引用
收藏
页码:1349 / 1355
页数:7
相关论文
共 50 条
  • [11] CT Calibration Curves for Proton Therapy: A Practical Approach
    Yeager, C.
    Ainsley, C.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [12] Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning
    Zhu, Jiahua
    Penfold, Scott N.
    MEDICAL PHYSICS, 2016, 43 (06) : 2845 - 2854
  • [13] Cross-calibration of interferometric SAR data
    Dall, J
    IEE PROCEEDINGS-RADAR SONAR AND NAVIGATION, 2003, 150 (03) : 177 - 183
  • [14] Revisiting the single-energy CT calibration for proton therapy treatment planning: a critical look at the stoichiometric method
    Goma, Carles
    Almeida, Isabel P.
    Verhaegen, Frank
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (23):
  • [15] Comparison of CT-number parameterization models for stoichiometric CT calibration in proton therapy
    Oden, Jakob
    Zimmerman, Jens
    Poludniowski, Gavin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 47 : 42 - 49
  • [16] Calibration of CT Hounsfield units for proton therapy treatment planning: use of kilovoltage and megavoltage images and comparison of parameterized methods
    De Marzi, L.
    Lesven, C.
    Ferrand, R.
    Sage, J.
    Boule, T.
    Mazal, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (12): : 4255 - 4276
  • [17] The calibration of CT Hounsfield units for radiotherapy treatment planning
    Schneider, U
    Pedroni, E
    Lomax, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (01): : 111 - 124
  • [18] Effect of CT Calibration Phantom Size On the Range in Proton Radiation Therapy
    Li, H.
    Liu, R.
    Wu, R.
    Sahoo, N.
    Mohan, R.
    Gillin, M.
    Zhu, X.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [19] Evaluation of Image Parameters Impact On the CT Calibration Curve for Proton Therapy
    Xiao, Z.
    Reyhan, M.
    Huang, Q.
    Zhang, M.
    Yue, N.
    Chen, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3423 - 3423
  • [20] CT calibration for two-dimensional scaling of proton pencil beams
    Szymanowski, H
    Oelfke, U
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (07): : 861 - 874