Closed-Vessel Conductively Heated Digestion System for the Elemental Analysis of Agricultural Materials by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS)

被引:3
|
作者
Traversa, Leonardo Clemente [1 ]
Santiago, Joao Victor Biagi [1 ]
de Oliveira, Evilim Martinez [1 ]
Ferreira, Edilene Cristina [1 ]
Virgilio, Alex [2 ]
Neto, Jose Anchieta Gomes [1 ]
机构
[1] Sao Paulo State Univ UNESP, Analyt Inorgan & Phys Chem Dept, Araraquara, SP, Brazil
[2] Univ Sao Paulo, Ctr Nucl Energy Agr CENA, DVTEC Sci Div, Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Agriculture materials; closed-vessel conductively heated digestion system (CHDS); high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS); SAMPLES;
D O I
10.1080/00032719.2023.2174133
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel applications of the closed-vessel conductively heated digestion system (CHDS) are proposed to digest biomass, biochar, oyster shell flour, bone meal and swine manure for the determination of Ca, K, Mg, Na, Cu, Fe, Mn, and Zn by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The performance of the digestion method using 14 and 7 mol L-1 HNO3 was checked by analyzing soil, rock, and plant certified reference materials (CRMs). For comparative purposes, all samples were analyzed after microwave-assisted digestion (MW-AD). Results obtained for most analytes by the closed-vessel conductively heated digestion system (CHDS) were in agreement with certified values and those attained by the comparative digestion method. The use of 7 mol L-1 HNO3 furnished lower blanks for most analytes and was effective to prepare challenging samples as biomass, biochar, shell and bone meal, swine manure, plants, soil, phosphate rock, and may be a good alternative for elemental determinations using most analytical techniques that rely on solution-based sample introduction systems. The detection limits (dry basis, mg kg(-1)) for Ca, Cu, Fe, K, Mg, Mn, Na, and Zn were 3, 0.4, 4, 4, 0.7, 0.4, 3, and 2, respectively. The mean relative standard deviations were close to 4.9% for closed-vessel conductively heated digestion (CHDS) and 5.9% for microwave-assisted digestion (MW-AD).
引用
收藏
页码:2443 / 2456
页数:14
相关论文
共 50 条
  • [31] High-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of solid samples and complex materials: a tutorial review
    Resano, Martin
    Aramendia, Maite
    Belarra, Miguel A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (12) : 2229 - 2250
  • [32] Spectral aspects of the determination of Si in organic and aqueous solutions using high-resolution continuum source or line source flame atomic absorption spectrometry
    Kowalewska, Zofia
    Pilarczyk, Janusz
    Gosciniak, Lukasz
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 120 : 45 - 56
  • [33] High-resolution continuum source graphite furnace atomic absorption spectrometry for screening elemental impurities in drugs to adhere to the new international guidelines
    Mattiazzi, Patricia
    Bohrer, Denise
    Becker, Emilene
    Viana, Carine
    Nascimento, Paulo C.
    Carvalho, Leandro M.
    TALANTA, 2019, 197 : 20 - 27
  • [34] Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry
    Bernhard Welz
    Maria Goreti R. Vale
    Daniel L. G. Borges
    Uwe Heitmann
    Analytical and Bioanalytical Chemistry, 2007, 389 : 2085 - 2095
  • [35] Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry
    Welz, B.
    Borges, D. L. G.
    Welz, B.
    Vale, M. G. R.
    Heitmann, U.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (7-8) : 2085 - 2095
  • [36] Preconcentration and Determination of Copper(II) by Novel Solid-Phase Extraction and High-Resolution Continuum Source Flame Atomic Absorption Spectrometry
    Baytak, Sitki
    Kasumov, Veli T.
    ANALYTICAL LETTERS, 2017, 50 (01) : 105 - 116
  • [37] Determination of Silicon in Vegetable Oil and Biodiesel by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry Using Sample Dilution with Xylene
    de Oliveira, Ligia C. C.
    Vieira, Mariana A.
    Ribeiro, Anderson S.
    Lisboa, Meibel T.
    Goncalves, Rodrigo A.
    de Campos, Reinaldo C.
    ENERGY & FUELS, 2012, 26 (11) : 7041 - 7044
  • [38] Determination of silicon in plant materials using direct solid sample analysis with high-resolution continuum source graphite furnace atomic absorption spectrometry
    Boschetti, Wiliam
    Dalagnol, Luiza M. G.
    Dullius, Mariana
    Zmozinski, Ariane V.
    Becker, Emilene M.
    Vale, Maria Goreti R.
    de Andrade, Jailson B.
    MICROCHEMICAL JOURNAL, 2016, 124 : 380 - 385
  • [39] Mercury Speciation in Fish by High-Performance Liquid Chromatography (HPLC) and Post-Column Ultraviolet (UV)-Photochemical Vapor Generation (PVG): Comparison of Conventional Line-Source and High-Resolution Continuum Source (HR-CS) Atomic Absorption Spectrometry (AAS)
    Linhart, Ondrej
    Kolorosova-Mrazova, Alzbeta
    Kratzer, Jan
    Hranicek, Jakub
    Cerveny, Vaclav
    ANALYTICAL LETTERS, 2019, 52 (04) : 613 - 632
  • [40] Determination of arsenic in agricultural soil samples using High-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Schneider, Mauana
    Cadorim, Heloisa R.
    Welz, Bernhard
    Carasek, Eduardo
    Feldmann, Jorg