Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry

被引:0
|
作者
Bernhard Welz
Maria Goreti R. Vale
Daniel L. G. Borges
Uwe Heitmann
机构
[1] Universidade Federal de Santa Catarina,Departamento de Química
[2] Universidade Federal da Bahia,Departamento de Química Analítica, Instituto de Química
[3] Universidade Federal do Rio Grande do Sul,Instituto de Química
[4] ISAS—Institute for Analytical Sciences,Department of Interface Spectroscopy
来源
关键词
Direct solid sample analysis; Electrothermal atomic absorption spectrometry; High-resolution continuum source atomic absorption spectrometry; Background correction; Calibration;
D O I
暂无
中图分类号
学科分类号
摘要
The literature about direct solid sample analysis of the past 10–15 years using electrothermal atomic absorption spectrometry has been reviewed. It was found that in the vast majority of publications aqueous standards were reported as having been used for calibration after careful program optimization. This means the frequently expressed claim that certified reference materials with a matrix composition and analyte content close to that of the sample have to be used for calibration in solid sample analysis is not confirmed in the more recent literature. There are obviously limitations, and there are examples in the literature where even calibration with certified reference materials did not lead to accurate results. In these cases the problem is typically associated with spectral interferences that cannot be corrected properly by the systems available for conventional line source atomic absorption spectrometry, including Zeeman-effect background correction. Using high-resolution continuum source atomic absorption spectrometry, spectral interferences become visible owing to the display of the spectral environment at both sides of the analytical line at high resolution, which makes program optimization straightforward. Any spectrally continuous background absorption is eliminated automatically, and even rapidly changing background absorption does not cause any artifacts, as measurement and correction of background absorption are truly simultaneous. Any kind of fine-structured background can be eliminated by “subtracting” reference spectra using a least-squares algorithm. Aqueous standards are used for calibration in all published applications of high-resolution continuum source atomic absorption spectrometry to direct solid sample analysis.
引用
收藏
页码:2085 / 2095
页数:10
相关论文
共 50 条
  • [1] Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry
    Welz, B.
    Borges, D. L. G.
    Welz, B.
    Vale, M. G. R.
    Heitmann, U.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (7-8) : 2085 - 2095
  • [2] Determination of silver in geological samples using high-resolution continuum source electrothermal atomic absorption spectrometry and direct solid sampling
    Ditter, Ingrid M.
    Borges, Daniel L. G.
    Welz, Bernhard
    Curtius, Adilson J.
    Becker-Ross, Helmut
    MICROCHIMICA ACTA, 2009, 167 (1-2) : 21 - 26
  • [3] Determination of silver in geological samples using high-resolution continuum source electrothermal atomic absorption spectrometry and direct solid sampling
    Ingrid M. Dittert
    Daniel L. G. Borges
    Bernhard Welz
    Adilson J. Curtius
    Helmut Becker-Ross
    Microchimica Acta, 2009, 167
  • [4] Direct determination of lead in bones using slurry sampling and high-resolution continuum source electrothermal atomic absorption spectrometry
    Husakova, Lenka
    Sidova, Tereza
    Ibrahimova, Lucie
    Svizelova, Monika
    Mikysek, Tomas
    ANALYTICAL METHODS, 2019, 11 (09) : 1254 - 1263
  • [5] Monitoring of Pd in airborne particulates by solid sampling high-resolution continuum source electrothermal atomic absorption spectrometry
    Atilgan, Semin
    Akman, Suleyman
    Baysal, Asli
    Bakircioglu, Yasemin
    Szigeti, Tamas
    Ovari, Mihaly
    Zaray, Gyula
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 70 : 33 - 38
  • [6] Simultaneous determination of Cd and Fe in grain products using direct solid sampling and high-resolution continuum source electrothermal atomic absorption spectrometry
    dos Santos, Lisia M. G.
    Araujo, Rennan G. O.
    Welz, Bernhard
    Jacob, Silvana Do C.
    Vale, Maria Goreti R.
    Becker-Ross, Helmut
    TALANTA, 2009, 78 (02) : 577 - 583
  • [7] Investigation of phosphorus atomization using high-resolution continuum source electrothermal atomic absorption spectrometry
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Lepri, Fabio G.
    Welz, Bernhard
    Heitmann, Uwe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (05) : 429 - 434
  • [8] Direct determination of chromium in infant formulas employing high-resolution continuum source electrothermal atomic absorption spectrometry and solid sample analysis
    Silva, Arlene S.
    Brandao, Geovani C.
    Matos, Geraldo D.
    Ferreira, Sergio L. C.
    TALANTA, 2015, 144 : 39 - 43
  • [9] Characterization of solid magnetic nanoparticles by means of solid sampling high resolution continuum source electrothermal atomic absorption spectrometry
    Vereda Alonso, E.
    Lopez Guerrero, M. M.
    Siles Cordero, M. T.
    Cano Pavon, J. M.
    Garcia de Torres, A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (12) : 2391 - 2398
  • [10] Determination of lead in coal using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry
    Gallindo Borges, DL
    da Silva, AF
    Curtius, AJ
    Welz, B
    Heitmann, U
    MICROCHIMICA ACTA, 2006, 154 (1-2) : 101 - 107