Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry

被引:0
|
作者
Bernhard Welz
Maria Goreti R. Vale
Daniel L. G. Borges
Uwe Heitmann
机构
[1] Universidade Federal de Santa Catarina,Departamento de Química
[2] Universidade Federal da Bahia,Departamento de Química Analítica, Instituto de Química
[3] Universidade Federal do Rio Grande do Sul,Instituto de Química
[4] ISAS—Institute for Analytical Sciences,Department of Interface Spectroscopy
来源
关键词
Direct solid sample analysis; Electrothermal atomic absorption spectrometry; High-resolution continuum source atomic absorption spectrometry; Background correction; Calibration;
D O I
暂无
中图分类号
学科分类号
摘要
The literature about direct solid sample analysis of the past 10–15 years using electrothermal atomic absorption spectrometry has been reviewed. It was found that in the vast majority of publications aqueous standards were reported as having been used for calibration after careful program optimization. This means the frequently expressed claim that certified reference materials with a matrix composition and analyte content close to that of the sample have to be used for calibration in solid sample analysis is not confirmed in the more recent literature. There are obviously limitations, and there are examples in the literature where even calibration with certified reference materials did not lead to accurate results. In these cases the problem is typically associated with spectral interferences that cannot be corrected properly by the systems available for conventional line source atomic absorption spectrometry, including Zeeman-effect background correction. Using high-resolution continuum source atomic absorption spectrometry, spectral interferences become visible owing to the display of the spectral environment at both sides of the analytical line at high resolution, which makes program optimization straightforward. Any spectrally continuous background absorption is eliminated automatically, and even rapidly changing background absorption does not cause any artifacts, as measurement and correction of background absorption are truly simultaneous. Any kind of fine-structured background can be eliminated by “subtracting” reference spectra using a least-squares algorithm. Aqueous standards are used for calibration in all published applications of high-resolution continuum source atomic absorption spectrometry to direct solid sample analysis.
引用
收藏
页码:2085 / 2095
页数:10
相关论文
共 50 条
  • [31] Determination of Polyorganosiloxanes (by Silicon) in Water by Extraction High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    Shtin, T. N.
    Gurvich, V. B.
    Galasheva, O. E.
    Shelomentsev, I. G.
    Neudachina, L. K.
    Shtin, S. A.
    INORGANIC MATERIALS, 2023, 59 (14) : 1387 - 1395
  • [32] Correction of structured molecular background by means of high-resolution continuum source electrothermal atomic absorption spectrometry-Determination of antimony in sediment reference materials using direct solid sampling
    Araujo, Rennan G. O.
    Welz, Bernhard
    Vignola, Fabiola
    Becker-Ross, Helmut
    TALANTA, 2009, 80 (02) : 846 - 852
  • [33] Direct determination of phosphorus in biological samples using a solid sampling-high resolution-continuum source electrothermal spectrometer: comparison of atomic and molecular absorption spectrometry
    Resano, Martin
    Briceno, Jorge
    Belarra, Miguel A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (10) : 1343 - 1354
  • [34] Three Advantages of High-Resolution Continuum Source Atomic Absorption Spectrometry
    Sun, Siqi
    SPECTROSCOPY, 2021, 36 (08) : 22 - 22
  • [35] High-Resolution Continuum Source Atomic and Molecular Absorption Spectrometry - A Review
    Welz, Bernhard
    Mores, Silvane
    Carasek, Eduardo
    Vale, Maria Goreti R.
    Okruss, Michael
    Becker-Ross, Helmut
    APPLIED SPECTROSCOPY REVIEWS, 2010, 45 (05) : 327 - 354
  • [36] Determination of silicon in plant materials using direct solid sample analysis with high-resolution continuum source graphite furnace atomic absorption spectrometry
    Boschetti, Wiliam
    Dalagnol, Luiza M. G.
    Dullius, Mariana
    Zmozinski, Ariane V.
    Becker, Emilene M.
    Vale, Maria Goreti R.
    de Andrade, Jailson B.
    MICROCHEMICAL JOURNAL, 2016, 124 : 380 - 385
  • [37] Determination of selenium in soil samples using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis
    Castilho, Ivan N. B.
    Pereira, Ederson R.
    Welz, Bernhard
    Shaltout, Abdallah A.
    Caraseka, Eduardo
    Martensd, Irland B. Gonzaga
    ANALYTICAL METHODS, 2014, 6 (09) : 2870 - 2875
  • [38] Determination of Lead in Eye Shadow and Blush by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry Employing Direct Solid Sampling
    Barros, Ariane I.
    Silva, Tiago V.
    Ferreira, Edilene C.
    Gomes Neto, Jose A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (01) : 140 - 146
  • [39] Determination of Mercury in Istanbul Airborne Particles Using Solid Sampling High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Baysal, Asli
    Akman, Suleyman
    ANALYTICAL LETTERS, 2016, 49 (12) : 1896 - 1902
  • [40] Molecule Formation Mechanisms of Strontium Mono Fluoride in High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    Ozbek, Nil
    Akman, Suleyman
    ANALYTICAL SCIENCES, 2013, 29 (07) : 741 - 746