Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry

被引:0
|
作者
Bernhard Welz
Maria Goreti R. Vale
Daniel L. G. Borges
Uwe Heitmann
机构
[1] Universidade Federal de Santa Catarina,Departamento de Química
[2] Universidade Federal da Bahia,Departamento de Química Analítica, Instituto de Química
[3] Universidade Federal do Rio Grande do Sul,Instituto de Química
[4] ISAS—Institute for Analytical Sciences,Department of Interface Spectroscopy
来源
关键词
Direct solid sample analysis; Electrothermal atomic absorption spectrometry; High-resolution continuum source atomic absorption spectrometry; Background correction; Calibration;
D O I
暂无
中图分类号
学科分类号
摘要
The literature about direct solid sample analysis of the past 10–15 years using electrothermal atomic absorption spectrometry has been reviewed. It was found that in the vast majority of publications aqueous standards were reported as having been used for calibration after careful program optimization. This means the frequently expressed claim that certified reference materials with a matrix composition and analyte content close to that of the sample have to be used for calibration in solid sample analysis is not confirmed in the more recent literature. There are obviously limitations, and there are examples in the literature where even calibration with certified reference materials did not lead to accurate results. In these cases the problem is typically associated with spectral interferences that cannot be corrected properly by the systems available for conventional line source atomic absorption spectrometry, including Zeeman-effect background correction. Using high-resolution continuum source atomic absorption spectrometry, spectral interferences become visible owing to the display of the spectral environment at both sides of the analytical line at high resolution, which makes program optimization straightforward. Any spectrally continuous background absorption is eliminated automatically, and even rapidly changing background absorption does not cause any artifacts, as measurement and correction of background absorption are truly simultaneous. Any kind of fine-structured background can be eliminated by “subtracting” reference spectra using a least-squares algorithm. Aqueous standards are used for calibration in all published applications of high-resolution continuum source atomic absorption spectrometry to direct solid sample analysis.
引用
收藏
页码:2085 / 2095
页数:10
相关论文
共 50 条
  • [21] Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling
    Borges, Daniel L. Gallindo
    da Silva, Alessandra Furtado
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (08) : 763 - 769
  • [22] Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling
    Borges, Daniel L. Gallindo
    Da Silva, Alessandra Furtado
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    Journal of Analytical Atomic Spectrometry, 2006, 21 (08): : 763 - 769
  • [23] Determination of cobalt in biological samples by line-source and high-resolution continuum source graphite furnace atomic absorption spectrometry using solid sampling or alkaline treatment
    Ribeiro, AS
    Vieira, MA
    da Silva, AF
    Borges, DLG
    Welz, B
    Heitmann, U
    Curtius, AJ
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (05) : 693 - 698
  • [24] Determination of mercury in biological samples using solid sampling high-resolution continuum source electrothermal atomization atomic absorption spectrometry with calibration against aqueous standards
    Da Silva, Alessandra Furtado
    Lepri, Fábio Grandis
    Borges, Daniel L. Gallindo
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    Journal of Analytical Atomic Spectrometry, 2006, 21 (11): : 1321 - 1326
  • [25] Determination of mercury in biological samples using solid sampling high-resolution continuum source electrothermal atomization atomic absorption spectrometry with calibration against aqueous standards
    da Silva, Alessandra Furtado
    Lepri, Fabio Grandis
    Borges, Daniel L. Gallindo
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (11) : 1321 - 1326
  • [26] Simultaneous determination of Cd and Fe in sewage sludge by high-resolution continuum source electrothermal atomic absorption spectrometry with slurry sampling
    Vignola, Fabiola
    Borges, Daniel L. G.
    Curtius, Adilson J.
    Welz, Bernhard
    Becker-Ross, Helmut
    MICROCHEMICAL JOURNAL, 2010, 95 (02) : 333 - 336
  • [27] Determination of lead in dietary supplements by high-resolution continuum-source graphite furnace atomic absorption spectrometry with direct solid sampling
    Leal, Gabriela Camera
    Mattiazzi, Patricia
    Rovasi, Franciele
    Dal Molin, Thais
    Bohrer, Denise
    do Nascimento, Paulo Cicero
    de Carvalho, Leandro M.
    Viana, Carine
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2020, 86
  • [28] Evaluation of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry for direct determination of chromium in medicinal plants
    Virgilio, Alex
    Nobrega, Joaquim A.
    Rego, Jardes F.
    Gomes Neto, Jose A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 78 : 58 - 61
  • [29] Direct solid sampling of biological species for the rapid determination of selenium by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Gomez-Nieto, Beatriz
    Gismera, M. Jesus
    Sevilla, M. Teresa
    Procopio, Jesus R.
    ANALYTICA CHIMICA ACTA, 2022, 1202
  • [30] Determination of Polyorganosiloxanes (by Silicon) in Water by Extraction High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    T. N. Shtin
    V. B. Gurvich
    O. E. Galasheva
    I. G. Shelomentsev
    L. K. Neudachina
    S. A. Shtin
    Inorganic Materials, 2023, 59 : 1387 - 1395