Progress in direct solid sampling analysis using line source and high-resolution continuum source electrothermal atomic absorption spectrometry

被引:0
|
作者
Bernhard Welz
Maria Goreti R. Vale
Daniel L. G. Borges
Uwe Heitmann
机构
[1] Universidade Federal de Santa Catarina,Departamento de Química
[2] Universidade Federal da Bahia,Departamento de Química Analítica, Instituto de Química
[3] Universidade Federal do Rio Grande do Sul,Instituto de Química
[4] ISAS—Institute for Analytical Sciences,Department of Interface Spectroscopy
来源
关键词
Direct solid sample analysis; Electrothermal atomic absorption spectrometry; High-resolution continuum source atomic absorption spectrometry; Background correction; Calibration;
D O I
暂无
中图分类号
学科分类号
摘要
The literature about direct solid sample analysis of the past 10–15 years using electrothermal atomic absorption spectrometry has been reviewed. It was found that in the vast majority of publications aqueous standards were reported as having been used for calibration after careful program optimization. This means the frequently expressed claim that certified reference materials with a matrix composition and analyte content close to that of the sample have to be used for calibration in solid sample analysis is not confirmed in the more recent literature. There are obviously limitations, and there are examples in the literature where even calibration with certified reference materials did not lead to accurate results. In these cases the problem is typically associated with spectral interferences that cannot be corrected properly by the systems available for conventional line source atomic absorption spectrometry, including Zeeman-effect background correction. Using high-resolution continuum source atomic absorption spectrometry, spectral interferences become visible owing to the display of the spectral environment at both sides of the analytical line at high resolution, which makes program optimization straightforward. Any spectrally continuous background absorption is eliminated automatically, and even rapidly changing background absorption does not cause any artifacts, as measurement and correction of background absorption are truly simultaneous. Any kind of fine-structured background can be eliminated by “subtracting” reference spectra using a least-squares algorithm. Aqueous standards are used for calibration in all published applications of high-resolution continuum source atomic absorption spectrometry to direct solid sample analysis.
引用
收藏
页码:2085 / 2095
页数:10
相关论文
共 50 条
  • [41] Molecule Formation Mechanisms of Strontium Mono Fluoride in High-Resolution Continuum Source Electrothermal Atomic Absorption Spectrometry
    Nil Ozbek
    Suleyman Akman
    Analytical Sciences, 2013, 29 : 741 - 746
  • [42] Determination of antimony in airborne particulate matter collected on filters using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry
    Araujo, Rennan G. O.
    Welz, Bernhard
    Castilho, Ivan N. B.
    Vale, Maria Goreti R.
    Smichowski, Patricia
    Ferreira, Sergio L. C.
    Becker-Ross, Helmut
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (04) : 580 - 584
  • [43] High-resolution continuum source electrothermal absorption spectrometry of AlBr and CaBr for the determination of bromine
    Huang, Mao Dong
    Becker-Ross, Helmut
    Florek, Stefan
    Heitmann, Uwe
    Okruss, Michael
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (05) : 566 - 570
  • [44] Direct solid sampling determination of lead in cheese varieties by high resolution continuum source graphite furnace atomic absorption spectrometry
    Tinas, Hande
    Ozbek, Nil
    Akman, Suleyman
    ANALYTICAL METHODS, 2017, 9 (45) : 6365 - 6370
  • [45] High-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of solid samples and complex materials: a tutorial review
    Resano, Martin
    Aramendia, Maite
    Belarra, Miguel A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (12) : 2229 - 2250
  • [46] Determination of silver in seawater by the direct analysis of solvent bars by high resolution continuum source solid sampling graphite furnace atomic absorption spectrometry
    Gonzalez-Alvarez, Rafael Jesus
    Bellido-Milla, Dolores
    Pinto, Juan Jose
    Moreno, Carlos
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (11) : 1925 - 1931
  • [48] CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY WITH HIGH-RESOLUTION AND WAVELENGTH MODULATION
    ZANDER, AT
    OHAVER, TC
    KELIHER, PN
    ANALYTICAL CHEMISTRY, 1976, 48 (08) : 1166 - 1175
  • [49] Feasibility of filter atomization in high-resolution continuum source atomic absorption spectrometry
    Heitmann, Uwe
    Becker-Ross, Helmut
    Katskov, Dmitri
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (03) : 351 - 360
  • [50] Quo vadis high-resolution continuum source atomic/molecular absorption spectrometry?
    Resano, M.
    Garcia-Ruiz, E.
    Aramendia, M.
    Belarra, M. A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (01) : 59 - 80