High-resolution continuum source graphite furnace atomic absorption spectrometry for screening elemental impurities in drugs to adhere to the new international guidelines

被引:13
|
作者
Mattiazzi, Patricia [1 ]
Bohrer, Denise [1 ]
Becker, Emilene [2 ]
Viana, Carine [1 ]
Nascimento, Paulo C. [3 ]
Carvalho, Leandro M. [3 ]
机构
[1] Univ Fed Santa Maria, Postgrad Program Pharmaceut Sci, Av Roraima 1000, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Inst Chem, Agron, AC Campus UFRGS, BR-91501970 Porto Alegre, RS, Brazil
[3] Univ Fed Santa Maria, Dept Chem, Av Roraima 1000, BR-97105900 Santa Maria, RS, Brazil
关键词
Elemental impurities; Drugs; Guidelines; Screening method; Catalysts; TRACE-ELEMENTS; CADMIUM; COPPER; CHROMIUM;
D O I
10.1016/j.talanta.2018.12.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New guidelines for the limits of elemental impurities in drug products were introduced by the International Council for Harmonization in 2014. While the guidelines define a limit for each element, the complete quantification of the 24 elements included is, in fact, unnecessary. An accurate "pass/fail" test to determine whether the threshold was exceeded or not could be valuable in this context. In this study, a screening procedure using the features of high-resolution continuum source graphite furnace atomic absorption spectrometry for the evaluation of 12 elements in three different drugs was developed. The three-dimensional absorbance spectrum including time and wavelength in the vicinity of the main line of the element allows for a pass/fail decision related to the presence or absence of the element in the sample. Additionally, the bi-dimensional absorbance wavelength spectrum defines the elements captured in the window when additional peaks are seen in the spectrum. The analysis of the selected drugs included sample digestion, the definition of pyrolysis and atomization temperatures, determination of the limit of detection and other validation parameters for each element. The evaluation of the spectra, both three- and bi-dimensional, revealed that only three elements, Cr, Ni, and Cu, were present in the samples in amounts above the LOD and therefore "fail" in the test. Nevertheless, they were quantified, and the analysis revealed that their levels were below the permitted daily exposure, which are at least 6 times higher than the LOD of the selected elements. Operating in a routine mode, the proposed method is a good option for the evaluation of elemental impurities in drug active ingredients or drug final products.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 50 条
  • [1] High-resolution continuum source graphite furnace atomic absorption spectrometry for the monitoring of Au nanoparticles
    Resano, Martin
    Garcia-Ruiz, Esperanza
    Garde, Raul
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (11) : 2233 - 2241
  • [2] High-resolution continuum source graphite furnace atomic absorption spectrometry for the monitoring of Au nanoparticles
    Resano, Martín (mresano@unizar.es), 1600, Royal Society of Chemistry (31):
  • [3] Simultaneous determination of rhodium and ruthenium by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Zambrzycka-Szelewa, Elzbieta
    Lulewicz, Marta
    Godlewska-Zylkiewicz, Beata
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 133 : 81 - 87
  • [4] High-resolution continuum source graphite furnace atomic absorption spectrometry: Is it as good as it sounds? A critical review
    Resano, Martin
    Garcia-Ruiz, Esperanza
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (01) : 323 - 330
  • [5] Direct determination of P in biodiesel by high-resolution continuum source graphite furnace atomic absorption spectrometry
    de Campos, Reinaldo Calixto
    Correia, Carolina Lyrio T.
    Vieira, Flavia
    Saint'Pierre, Tatiana D.
    Oliveira, Ana Cristina
    Goncalves, Rodrigo
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) : 352 - 355
  • [6] High-resolution continuum source graphite furnace atomic absorption spectrometry: Is it as good as it sounds? A critical review
    Martín Resano
    Esperanza García-Ruiz
    Analytical and Bioanalytical Chemistry, 2011, 399 : 323 - 330
  • [7] Determination of Cu and Mn in Seawater by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Burylin, Mikhail Yu
    Kopeyko, Elena S.
    Bauer, Viktoriya A.
    ANALYTICAL LETTERS, 2022, 55 (10) : 1663 - 1671
  • [8] Graphite tubes with small internal diameters tailored for high-resolution continuum source graphite furnace atomic absorption spectrometry
    Huang, Mao Dong
    Becker-Ross, Helmut
    Okruss, Michael
    Geisler, Sebastian
    Florek, Stefan
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2012, 27 (06) : 982 - 988
  • [9] Determination of heavy metals in cigarettes using high-resolution continuum source graphite furnace atomic absorption spectrometry
    Ren, Ting
    Chen, Xi
    Ge, Yao
    Zhao, Lijiao
    Zhong, Rugang
    ANALYTICAL METHODS, 2017, 9 (27) : 4033 - 4043
  • [10] Investigation of chemical modifiers for phosphorus in a graphite furnace using high-resolution continuum source atomic absorption spectrometry
    Lepri, Fabio G.
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Borges, Daniel L. G.
    Welz, Bernhard
    Heitmann, Uwe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2006, 61 (08) : 934 - 944