High-resolution continuum source graphite furnace atomic absorption spectrometry for screening elemental impurities in drugs to adhere to the new international guidelines

被引:13
|
作者
Mattiazzi, Patricia [1 ]
Bohrer, Denise [1 ]
Becker, Emilene [2 ]
Viana, Carine [1 ]
Nascimento, Paulo C. [3 ]
Carvalho, Leandro M. [3 ]
机构
[1] Univ Fed Santa Maria, Postgrad Program Pharmaceut Sci, Av Roraima 1000, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Inst Chem, Agron, AC Campus UFRGS, BR-91501970 Porto Alegre, RS, Brazil
[3] Univ Fed Santa Maria, Dept Chem, Av Roraima 1000, BR-97105900 Santa Maria, RS, Brazil
关键词
Elemental impurities; Drugs; Guidelines; Screening method; Catalysts; TRACE-ELEMENTS; CADMIUM; COPPER; CHROMIUM;
D O I
10.1016/j.talanta.2018.12.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New guidelines for the limits of elemental impurities in drug products were introduced by the International Council for Harmonization in 2014. While the guidelines define a limit for each element, the complete quantification of the 24 elements included is, in fact, unnecessary. An accurate "pass/fail" test to determine whether the threshold was exceeded or not could be valuable in this context. In this study, a screening procedure using the features of high-resolution continuum source graphite furnace atomic absorption spectrometry for the evaluation of 12 elements in three different drugs was developed. The three-dimensional absorbance spectrum including time and wavelength in the vicinity of the main line of the element allows for a pass/fail decision related to the presence or absence of the element in the sample. Additionally, the bi-dimensional absorbance wavelength spectrum defines the elements captured in the window when additional peaks are seen in the spectrum. The analysis of the selected drugs included sample digestion, the definition of pyrolysis and atomization temperatures, determination of the limit of detection and other validation parameters for each element. The evaluation of the spectra, both three- and bi-dimensional, revealed that only three elements, Cr, Ni, and Cu, were present in the samples in amounts above the LOD and therefore "fail" in the test. Nevertheless, they were quantified, and the analysis revealed that their levels were below the permitted daily exposure, which are at least 6 times higher than the LOD of the selected elements. Operating in a routine mode, the proposed method is a good option for the evaluation of elemental impurities in drug active ingredients or drug final products.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 50 条
  • [21] Elemental Analysis of Pharmaceutical Products for Chronic Kidney Disease by High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS GFAAS)
    Maziero, Maiara
    Adolfo, Franciele Rovasi
    Camera Leal, Gabriela
    de Carvalho, Leandro Machado
    Nascimento, Paulo Cicero do
    Viana, Carine
    ANALYTICAL LETTERS, 2022, 55 (01) : 109 - 122
  • [22] Determination of lead in coal using direct solid sampling and high-resolution continuum source graphite furnace atomic absorption spectrometry
    Gallindo Borges, DL
    da Silva, AF
    Curtius, AJ
    Welz, B
    Heitmann, U
    MICROCHIMICA ACTA, 2006, 154 (1-2) : 101 - 107
  • [23] Determination of Antimony in Pharmaceutical Formulations and Beverages Using High-Resolution Continuum-Source Graphite Furnace Atomic Absorption Spectrometry
    Mattiazzi, Patricia
    Bohrer, Denise
    Viana, Carine
    do Nascimento, Paulo Cicero
    Veiga, Marlei
    de Carvalho, Leandro Machado
    JOURNAL OF AOAC INTERNATIONAL, 2017, 100 (03) : 737 - 743
  • [24] Determination of Cd, Ni and V in Spices by Solid Sampling High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Virgilio, Alex
    Rego, Jardes F.
    Barros, Ariane I.
    Gomes Neto, Jose A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (10) : 1988 - 1993
  • [25] Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling
    Borges, Daniel L. Gallindo
    da Silva, Alessandra Furtado
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (08) : 763 - 769
  • [26] Simultaneous Determination of Chromium and Iron in Powdered Milk Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Adilson S. Santos
    Cheilane T. de Souza
    Danilo J. Leao
    Felipo O. Correia
    Tarcísio S. Almeida
    Sergio L. C. Ferreira
    Food Analytical Methods, 2020, 13 : 284 - 290
  • [27] Determination of Lead in Coal Using Direct Solid Sampling and High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Daniel L. Gallindo Borges
    Alessandra Furtado da Silva
    Adilson José Curtius
    Bernhard Welz
    Uwe Heitmann
    Microchimica Acta, 2006, 154 : 101 - 107
  • [28] Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling
    Borges, Daniel L. Gallindo
    Da Silva, Alessandra Furtado
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    Journal of Analytical Atomic Spectrometry, 2006, 21 (08): : 763 - 769
  • [29] Simultaneous Determination of Chromium and Iron in Powdered Milk Using High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Santos, Adilson S.
    de Souza, Cheilane T.
    Leao, Danilo J.
    Correia, Felipo O.
    Almeida, Tarcisio S.
    Ferreira, Sergio L. C.
    FOOD ANALYTICAL METHODS, 2020, 13 (01) : 284 - 290
  • [30] Simultaneous determination of iron and nickel in fluoropolymers by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry
    Soares, Bruno M.
    Santos, Rafael F.
    Bolzan, Rodrigo C.
    Muller, Edson I.
    Primel, Ednei G.
    Duarte, Fabio A.
    TALANTA, 2016, 160 : 454 - 460