High-resolution continuum source graphite furnace atomic absorption spectrometry for screening elemental impurities in drugs to adhere to the new international guidelines

被引:13
|
作者
Mattiazzi, Patricia [1 ]
Bohrer, Denise [1 ]
Becker, Emilene [2 ]
Viana, Carine [1 ]
Nascimento, Paulo C. [3 ]
Carvalho, Leandro M. [3 ]
机构
[1] Univ Fed Santa Maria, Postgrad Program Pharmaceut Sci, Av Roraima 1000, BR-97105900 Santa Maria, RS, Brazil
[2] Univ Fed Rio Grande do Sul, Inst Chem, Agron, AC Campus UFRGS, BR-91501970 Porto Alegre, RS, Brazil
[3] Univ Fed Santa Maria, Dept Chem, Av Roraima 1000, BR-97105900 Santa Maria, RS, Brazil
关键词
Elemental impurities; Drugs; Guidelines; Screening method; Catalysts; TRACE-ELEMENTS; CADMIUM; COPPER; CHROMIUM;
D O I
10.1016/j.talanta.2018.12.068
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
New guidelines for the limits of elemental impurities in drug products were introduced by the International Council for Harmonization in 2014. While the guidelines define a limit for each element, the complete quantification of the 24 elements included is, in fact, unnecessary. An accurate "pass/fail" test to determine whether the threshold was exceeded or not could be valuable in this context. In this study, a screening procedure using the features of high-resolution continuum source graphite furnace atomic absorption spectrometry for the evaluation of 12 elements in three different drugs was developed. The three-dimensional absorbance spectrum including time and wavelength in the vicinity of the main line of the element allows for a pass/fail decision related to the presence or absence of the element in the sample. Additionally, the bi-dimensional absorbance wavelength spectrum defines the elements captured in the window when additional peaks are seen in the spectrum. The analysis of the selected drugs included sample digestion, the definition of pyrolysis and atomization temperatures, determination of the limit of detection and other validation parameters for each element. The evaluation of the spectra, both three- and bi-dimensional, revealed that only three elements, Cr, Ni, and Cu, were present in the samples in amounts above the LOD and therefore "fail" in the test. Nevertheless, they were quantified, and the analysis revealed that their levels were below the permitted daily exposure, which are at least 6 times higher than the LOD of the selected elements. Operating in a routine mode, the proposed method is a good option for the evaluation of elemental impurities in drug active ingredients or drug final products.
引用
收藏
页码:20 / 27
页数:8
相关论文
共 50 条
  • [31] Determination of Silver in Environmental Samples by High-resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry after Preconcentration on Bentonite
    Magdalena Krawczyk-Coda
    Journal of Analytical Chemistry, 2022, 77 : 1155 - 1161
  • [32] Determination of Silver in Environmental Samples by High-resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry after Preconcentration on Bentonite
    Krawczyk-Coda, Magdalena
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (09) : 1155 - 1161
  • [33] Determination of Pb and Cr in sunscreen samples by high-resolution continuum source graphite furnace atomic absorption spectrometry and direct analysis
    Zmozinski, Ariane V.
    Pretto, Tatiane
    Borges, Aline R.
    Duarte, Alvaro T.
    Vale, Maria Goreti R.
    MICROCHEMICAL JOURNAL, 2016, 128 : 89 - 94
  • [34] Fast and direct screening of copper in micro-volumes of distilled alcoholic beverages by high-resolution continuum source graphite furnace atomic absorption spectrometry
    Ajtony, Zsolt
    Laczai, Nikoletta
    Dravecz, Gabriella
    Szoboszlai, Norbert
    Marosi, Aron
    Marlok, Bence
    Streli, Christina
    Bencs, Laszlo
    FOOD CHEMISTRY, 2016, 213 : 799 - 805
  • [35] Determination of residual dimethyl sulfoxide by high-resolution continuum source graphite furnace molecular absorption spectrometry
    Huang, Mao Dong
    Esser, Norbert
    Hinrichs, Karsten
    Tan, Qin
    Rappich, Jorg
    Nickel, Norbert H.
    Dittrich, Thomas
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2021, 177
  • [36] Determination of Pb, Cd and Cr in Food by High Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry
    Ren Ting
    Zhao Li-jiao
    Cao Jun
    Zhong Ru-gang
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (09) : 2566 - 2571
  • [37] Three Advantages of High-Resolution Continuum Source Atomic Absorption Spectrometry
    Sun, Siqi
    SPECTROSCOPY, 2021, 36 (08) : 22 - 22
  • [38] High-Resolution Continuum Source Atomic and Molecular Absorption Spectrometry - A Review
    Welz, Bernhard
    Mores, Silvane
    Carasek, Eduardo
    Vale, Maria Goreti R.
    Okruss, Michael
    Becker-Ross, Helmut
    APPLIED SPECTROSCOPY REVIEWS, 2010, 45 (05) : 327 - 354
  • [39] Determination of lead in dietary supplements by high-resolution continuum-source graphite furnace atomic absorption spectrometry with direct solid sampling
    Leal, Gabriela Camera
    Mattiazzi, Patricia
    Rovasi, Franciele
    Dal Molin, Thais
    Bohrer, Denise
    do Nascimento, Paulo Cicero
    de Carvalho, Leandro M.
    Viana, Carine
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2020, 86
  • [40] Evaluation of solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry for direct determination of chromium in medicinal plants
    Virgilio, Alex
    Nobrega, Joaquim A.
    Rego, Jardes F.
    Gomes Neto, Jose A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 78 : 58 - 61