Closed-Vessel Conductively Heated Digestion System for the Elemental Analysis of Agricultural Materials by High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS FAAS)

被引:3
|
作者
Traversa, Leonardo Clemente [1 ]
Santiago, Joao Victor Biagi [1 ]
de Oliveira, Evilim Martinez [1 ]
Ferreira, Edilene Cristina [1 ]
Virgilio, Alex [2 ]
Neto, Jose Anchieta Gomes [1 ]
机构
[1] Sao Paulo State Univ UNESP, Analyt Inorgan & Phys Chem Dept, Araraquara, SP, Brazil
[2] Univ Sao Paulo, Ctr Nucl Energy Agr CENA, DVTEC Sci Div, Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Agriculture materials; closed-vessel conductively heated digestion system (CHDS); high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS); SAMPLES;
D O I
10.1080/00032719.2023.2174133
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Novel applications of the closed-vessel conductively heated digestion system (CHDS) are proposed to digest biomass, biochar, oyster shell flour, bone meal and swine manure for the determination of Ca, K, Mg, Na, Cu, Fe, Mn, and Zn by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The performance of the digestion method using 14 and 7 mol L-1 HNO3 was checked by analyzing soil, rock, and plant certified reference materials (CRMs). For comparative purposes, all samples were analyzed after microwave-assisted digestion (MW-AD). Results obtained for most analytes by the closed-vessel conductively heated digestion system (CHDS) were in agreement with certified values and those attained by the comparative digestion method. The use of 7 mol L-1 HNO3 furnished lower blanks for most analytes and was effective to prepare challenging samples as biomass, biochar, shell and bone meal, swine manure, plants, soil, phosphate rock, and may be a good alternative for elemental determinations using most analytical techniques that rely on solution-based sample introduction systems. The detection limits (dry basis, mg kg(-1)) for Ca, Cu, Fe, K, Mg, Mn, Na, and Zn were 3, 0.4, 4, 4, 0.7, 0.4, 3, and 2, respectively. The mean relative standard deviations were close to 4.9% for closed-vessel conductively heated digestion (CHDS) and 5.9% for microwave-assisted digestion (MW-AD).
引用
收藏
页码:2443 / 2456
页数:14
相关论文
共 50 条
  • [21] Determination of Iron and Zinc in Garbanzo by Microwave Digestion-High Resolution Continuum Source Flame Atomic Absorption Spectrometry
    Liu, Quan-de
    Chen, Shang-long
    Li, Yong
    Gao, Jing
    Zhu, Yun-xu
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON ADVANCED DESIGN AND MANUFACTURING ENGINEERING, 2015, 39 : 1004 - 1007
  • [22] A practical method for the determination of sulphur in coal samples by high-resolution continuum source flame atomic absorption spectrometry
    Baysal, A.
    Akman, S.
    TALANTA, 2011, 85 (05) : 2662 - 2665
  • [23] Fabrication and characterization of MgCo2O4 for solid phase extraction of Pb(II) from environmental samples and its detection with high-resolution continuum source flame atomic absorption spectrometry (HR-CS-FAAS)
    Soylak, Mustafa
    Alasaad, Mohamed
    Ozalp, Ozgur
    MICROCHEMICAL JOURNAL, 2022, 178
  • [24] High-throughput sugarcane leaf analysis using a low cost closed-vessel conductively heated digestion system and inductively coupled plasma optical emission spectroscopy
    Miranda, Kelber
    Vieira, Alan Lima
    Gomes Neto, Jose Anchieta
    ANALYTICAL METHODS, 2014, 6 (23) : 9503 - 9508
  • [25] HIGH-RESOLUTION CONTINUUM SOURCE ATOMIC-ABSORPTION SPECTROMETRY IN AN AIR-ACETYLENE FLAME WITH PHOTODIODE ARRAY DETECTION
    JONES, BT
    MIGNARDI, MA
    SMITH, BW
    WINEFORDNER, JD
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (07) : 647 - 651
  • [26] High-resolution continuum source electrothermal atomic absorption spectrometry - An analytical and diagnostic tool for trace analysis
    Welz, Bernhard
    Borges, Daniel L. G.
    Lepri, Fabio G.
    Vale, Maria Goreti R.
    Heitmann, Uwe
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (09) : 873 - 883
  • [27] Determination of germanium in plant and soil samples using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) with solid sampling
    Schreiter, Norbert
    Wiche, Oliver
    Aubel, Ines
    Roode-Gutzmer, Quirina
    Bertau, Martin
    JOURNAL OF GEOCHEMICAL EXPLORATION, 2021, 220
  • [28] Effective and High-Throughput Analytical Methodology for the Determination of Lead and Cadmium in Water Samples by Disposable Pipette Extraction Coupled with High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (HR-CS GF AAS)
    Cadorim, Heloisa R.
    Schneider, Mauana
    Hinz, Julia
    Luvizon, Fabiana
    Dias, Adriana N.
    Carasek, Eduardo
    Welz, Bernhard
    ANALYTICAL LETTERS, 2019, 52 (13) : 2133 - 2149
  • [29] Fast sequential determination of antimony and lead in pewter alloys using high-resolution continuum source flame atomic absorption spectrometry
    Dessuy, Morgana B.
    de Jesus, Robson M.
    Brandao, Geovani C.
    Ferreira, Sergio L. C.
    Vale, Maria Goreti R.
    Welz, Bernhard
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2013, 30 (01): : 202 - 207
  • [30] Screening method for extractable organically bound fluorine (EOF) in river water samples by means of high-resolution–continuum source graphite furnace molecular absorption spectrometry (HR-CS GF MAS)
    Matthias Metzger
    Philip Ley
    Manfred Sturm
    Björn Meermann
    Analytical and Bioanalytical Chemistry, 2019, 411 : 4647 - 4660