Enhanced honey badger optimization of performance analysis of evacuated tube heat pipe solar collector integrated with PCM storage unit

被引:1
|
作者
Ramesh, C. [1 ,5 ]
Vijayakumar, M. [2 ]
Kumaresan, G. [3 ]
Selvanayagam, Benjamin Franklin [4 ]
机构
[1] KIT Kalaignar Karunanidhi Inst Technol, Dept Mech Engn, Coimbatore, Tamil Nadu, India
[2] PSN Coll Engn & Technol, Dept Mech Engn, Tirunelveli, Tamil Nadu, India
[3] Bannari Amman Inst Technol, Dept Mech Engn, Sathyamangalam, Tamil Nadu, India
[4] Sri Ramakrishna Inst Technol, Dept Mech Engn, Coimbatore, Tamil Nadu, India
[5] KIT Kalaignar Karunanidhi Inst Technol, Dept Mech Engn, Coimbatore 641402, Tamil Nadu, India
关键词
Heat pipe; phase change material; aluminum fin; fin temperature; optimization; thermal energy storage; liquid fractions; PHASE-CHANGE MATERIAL; THERMAL PERFORMANCE; WATER-HEATER; SYSTEM; TANK;
D O I
10.1177/0958305X231189187
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A hybrid method for improving the efficiency of heat pipe evacuated-tube solar-collector (HPETC) is proposed for incorporating the phase-change materials (PCMs) in both off-demand and regular operation. The proposed hybrid approach is called an improved honey badger algorithm (HBA). The crossover and mutation operator improves the honey badger's (HB) foraging habit. The proposed approach aims to generate hot air at various rates of airflow under incident and nonincident solar-radiation situations. The analysis is done on the effects of different energy-storage systems and the position of the heat pipe (HP). In a normal heat-pipe evacuated-tube solar collector, the HP is put within the glass tube that is closer to the upper-surface, and it is held in place through an aluminum fin. However, in the proposed method, the HP is rearranged in the tube's middle. In order to identify the PCM with the highest average-fin temperature, the temperatures of the area-weighted average-fin are measured and compared throughout the glass tubes under typical conditions. For maximizing the thermal-energy carrying capability, the average liquid fraction volume of PCMs is measured for a 24-h flow period. The average liquid-fraction volume of PCMs is continuously observed in stagnation mode till the glass tube reaches the maximal value. The structured mesh patch conforming method is used to invalidate the HPETC system's constituent parts, improving numerical stability and convergence. The proposed method efficiency is 0.43. The proposed method shows high efficiency compared with other existing methods.
引用
收藏
页数:28
相关论文
共 50 条
  • [21] Theoretical model of an evacuated tube heat pipe solar collector integrated with phase change material
    Naghavi, M. S.
    Ong, K. S.
    Badruddin, I. A.
    Mehrali, M.
    Silakhori, M.
    Metselaar, H. S. C.
    ENERGY, 2015, 91 : 911 - 924
  • [22] Evacuated tube solar heat pipe collector model and associated tests
    Jafarkazemi, Farzad
    Abdi, Hossein
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2012, 4 (02)
  • [23] Thermal performance of phase change material integrated heat pipe evacuated tube solar collector system: An experimental assessment
    Chopra, K.
    Pathak, Atin K.
    Tyagi, V. V.
    Pandey, A. K.
    Anand, Sanjeev
    Sari, Ahmet
    ENERGY CONVERSION AND MANAGEMENT, 2020, 203
  • [24] An integrated solar desalination with evacuated tube heat pipe solar collector and new wind ventilator external condenser
    Shoeibi, Shahin
    Kargarsharifabad, Hadi
    Rahbar, Nader
    Khosravi, Gholamreza
    Sharifpur, Mohsen
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 50
  • [25] Theoretical and experimental analysis of thermal performance of a solar water heating system with evacuated tube heat pipe collector
    Daghigh, Roonak
    Shafieian, Abdellah
    APPLIED THERMAL ENGINEERING, 2016, 103 : 1219 - 1227
  • [26] Heat transfer enhancement of a PCM-porous metal based heat pipe evacuated tube solar collector: An experimental study
    Pawar, Vivek R.
    Sobhansarbandi, Sarvenaz
    SOLAR ENERGY, 2023, 251 : 106 - 118
  • [27] Performance investigation on a sun-tracking CPC heat pipe evacuated tube solar collector
    SUN Wei
    WANG Yinfeng
    CHEN Haijun
    MA Tingting
    ZHA Junjie
    YANG Moucun
    ZHU Yuezhao
    热力发电, 2013, 42 (11) : 26 - 30
  • [28] Thermal performance and parameter analysis of a U-pipe evacuated solar tube collector
    Gao, Y.
    Fan, R.
    Zhang, X. Y.
    An, Y. J.
    Wang, M. X.
    Gao, Y. K.
    Yu, Y.
    SOLAR ENERGY, 2014, 107 : 714 - 727
  • [29] Numerical study of an Evacuated Tube Solar Collector incorporating a Nano-PCM as a latent heat storage system
    Elarem, Raja
    Alqahtani, Talal
    Mellouli, Sofiene
    Aich, Walid
    Ben Khedher, Nidhal
    Kolsi, Lioua
    Jemni, Abdelmajid
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 24
  • [30] Enhanced performance assessment of an integrated evacuated tube and flat plate collector solar air heater with thermal storage material
    El-Fakharany, Magda K.
    Abo-Samra, Aly-Eldeen A.
    Abdelmaqsoud, A. M.
    Marzouk, S. A.
    APPLIED THERMAL ENGINEERING, 2024, 243