An integrated solar desalination with evacuated tube heat pipe solar collector and new wind ventilator external condenser

被引:59
|
作者
Shoeibi, Shahin [1 ]
Kargarsharifabad, Hadi [1 ]
Rahbar, Nader [1 ]
Khosravi, Gholamreza [1 ]
Sharifpur, Mohsen [2 ,3 ,4 ]
机构
[1] Islamic Azad Univ, Semnan Branch, Energy & Sustainable Dev Res Ctr, Semnan, Iran
[2] Univ Pretoria, Dept Mech & Aeronaut Engn, Clean Energy Res Grp, Engn 3, Lynnwood Rd, ZA-0002 Pretoria, South Africa
[3] China Med Univ, China Med Univ Hosp, Dept Med Res, Taichung 404, Taiwan
[4] Univ Sci & Culture, Dept Mech Engn, Tehran, Iran
关键词
Solar desalination; Evacuated tube heat pipe; Wind ventilator; Water cooling; Environmental analysis; ECONOMIC-ANALYSIS; ENERGY MATRICES; MASS-TRANSFER; STILL; WATER; EXERGY; PERFORMANCE; SINGLE; NANOFLUIDS; ENHANCEMENT;
D O I
10.1016/j.seta.2021.101857
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Over the recent decades, many investigations have been performed to enhance the performance of solar desalination. Some of these studies improved the saline water temperature, while others decreased the glass cover temperature. This study has investigated single-slope solar still using an evacuated tube heat pipe solar collector (ETHP-SC) and a new design of external condenser. The ETHP-SC increased the saline water temperature. On the other hand, the external condenser enhanced the condensation rate using a wind ventilator and a water cooling system. The pressure inside the modified solar desalination decreased by the suction of water vapor with the wind ventilator. The water vapor flowed to the external condenser and was distilled by hitting the perforated copper plate connected to the water cooling system. Results revealed that the freshwater generation of solar desalination using an external condenser and ETHP was about 2.13 times those of conventional ones. The yield fraction of the external condenser was about 18.62% of the total water productivity. Moreover, the carbon dioxide mitigation was almost 29.19 tons and 0.51 tons based on environmental and exergoenvironmental analysis in the modified solar desalination, respectively.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] An active solar desalination system integrated with collective condenser heat pipe solar evacuated tube collector: a thermoeconomic analysis
    Nema, Garima
    Krishnasamy, Karunamurthy
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2024, 31 (07) : 10273 - 10295
  • [2] An active solar desalination system integrated with collective condenser heat pipe solar evacuated tube collector: a thermoeconomic analysis
    Garima Nema
    Karunamurthy Krishnasamy
    Environmental Science and Pollution Research, 2024, 31 : 10273 - 10295
  • [3] WATER DESALINATION BY EVACUATED TUBE HEAT PIPE SOLAR COLLECTOR
    Alwaer, A.
    Gryzagoridis, J.
    PROCEEDINGS OF THE 2014 11TH INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2014, : 364 - 368
  • [4] Design of Evacuated Tube Solar Collector with Heat Pipe
    Kumar, S. Siva
    Kumar, K. Mohan
    Kumar, S. R. Sanjeev
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (14) : 12641 - 12646
  • [5] A novel solar desalination system based on an evacuated tube collective condenser heat pipe solar collector: A thermo-economic and environmental analysis
    Nema, Garima
    Karunamurthy, K.
    FRONTIERS IN MECHANICAL ENGINEERING-SWITZERLAND, 2022, 8
  • [6] Performance of evacuated tube solar collector integrated solar desalination unit - a review
    Kumar, Rajeev
    Singh, Desh Bandhu
    Dewangan, Ashish
    Singh, Vivek Kumar
    Kumar, Navneet
    DESALINATION AND WATER TREATMENT, 2021, 230 : 92 - 115
  • [7] Evacuated tube heat pipe solar collector for Encontech engine-driven reverse osmosis solar desalination
    Takalkar, Gorakshnath
    Bhosale, Rahul R.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (15) : 12460 - 12473
  • [8] Thermal Performance of Evacuated Tube Heat Pipe Solar Collector
    Putra, Nandy
    Kristian, M. R.
    David, R.
    Haliansyah, K.
    Ariantara, Bambang
    PROCEEDINGS OF THE 3RD AUN/SEED-NET REGIONAL CONFERENCE ON ENERGY ENGINEERING AND THE 7TH INTERNATIONAL CONFERENCE ON THERMOFLUIDS (RCENE/THERMOFLUID 2015), 2016, 1737
  • [9] Experimental study of a solar water desalination system utilizing evacuated tube heat pipe collector
    Alwaer, A.
    Gryzagoridis, J.
    PROCEEDINGS OF THE TWENTY-THIRD CONFERENCE ON THE DOMESTIC USE OF ENERGY, 2015, : 155 - 162
  • [10] EVACUATED HEAT PIPE SOLAR COLLECTOR
    MAHDJURI, F