Experimental study of a solar water desalination system utilizing evacuated tube heat pipe collector

被引:0
|
作者
Alwaer, A. [1 ]
Gryzagoridis, J. [2 ,3 ]
机构
[1] Minist Higher Educ Libya, Tech Educ Commiss, Tripoli, Libya
[2] Cape Peninsula Univ Technol, Dept Mech Engn, Cape Town, South Africa
[3] Univ Cape Town, Cape Town, South Africa
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents results that were obtained utilizing an evacuated tube heat pipe solar collector, while performing as a solar water desalination system. Data was obtained indoors by the use of a solar simulator (consisting of an array of halogen Flood lights) during experiments conducted in the Department of Mechanical Engineering at Cape Peninsula University of Technology (CPUT). The irradiance from the solar simulator that could be controlled by means of variable transformers varying the voltage to the halogen lamps was measured over the surface of the evacuated heat pipe collector. The procedure allowed for exposure of the collector to the solar simulator for seven hours daily and thereafter normal cooling of the system. Initial testing produced encouraging results. Modifying the system slightly to operate at lowers than atmospheric pressure, evaporation obviously took place at lower temperatures and the amount of potable water harvested increased relative to previous tests.
引用
收藏
页码:155 / 162
页数:8
相关论文
共 50 条
  • [1] WATER DESALINATION BY EVACUATED TUBE HEAT PIPE SOLAR COLLECTOR
    Alwaer, A.
    Gryzagoridis, J.
    PROCEEDINGS OF THE 2014 11TH INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2014, : 364 - 368
  • [2] Experimental Investigation of Solar Desalination System Using Evacuated Tube Collector
    Kedar, Shridhar
    Kumaravel, Arul Raj
    Bewoor, Anand K.
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2019, 37 (02) : 527 - 532
  • [3] Theoretical and experimental analysis of thermal performance of a solar water heating system with evacuated tube heat pipe collector
    Daghigh, Roonak
    Shafieian, Abdellah
    APPLIED THERMAL ENGINEERING, 2016, 103 : 1219 - 1227
  • [4] Design of Evacuated Tube Solar Collector with Heat Pipe
    Kumar, S. Siva
    Kumar, K. Mohan
    Kumar, S. R. Sanjeev
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (14) : 12641 - 12646
  • [5] An active solar desalination system integrated with collective condenser heat pipe solar evacuated tube collector: a thermoeconomic analysis
    Nema, Garima
    Krishnasamy, Karunamurthy
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2024, 31 (07) : 10273 - 10295
  • [6] An active solar desalination system integrated with collective condenser heat pipe solar evacuated tube collector: a thermoeconomic analysis
    Garima Nema
    Karunamurthy Krishnasamy
    Environmental Science and Pollution Research, 2024, 31 : 10273 - 10295
  • [7] EXPERIMENTAL INVESTIGATION OF ENERGY CHARACTERISTICS OF EVACUATED TUBE HEAT-PIPE SOLAR COLLECTOR SYSTEM
    Kavolynas, Antanas
    Drejeris, Rolandas
    7TH INTERNATIONAL SCIENTIFIC CONFERENCE RURAL DEVELOPMENT 2015: TOWARDS THE TRANSFER OF KNOWLEDGE, INNOVATIONS AND SOCIAL PROGRESS, 2015,
  • [8] Experimental evaluation of the efficiency of a solar tube collector evacuated with and without heat pipe
    Eufracio Arias, Wilder Efrain
    Abregu Rodriguez, Nathaly Ibeth
    Rodriguez Espinoza, Dayana
    FUENTES EL REVENTON ENERGETICO, 2019, 17 (01): : 7 - 17
  • [9] Desalination system using evacuated tube heat pipe solar collector with improved insulation of the geyser March 2019
    Alwaer, A.
    Gryzagoridis, J.
    PROCEEDINGS OF THE 2019 TWENTY SEVENTH INTERNATIONAL CONFERENCE ON THE DOMESTIC USE OF ENERGY (DUE), 2019, : 140 - 146
  • [10] An experimental study of a heat pipe evacuated tube solar dryer with heat recovery system
    Daghigh, Roonak
    Shafieian, Abdellah
    RENEWABLE ENERGY, 2016, 96 : 872 - 880