Optimization of 3x3 inch NaI(Tl) detector related to energy, distance and bias voltage

被引:13
|
作者
Kuluozturk, Muhammed Fatih [1 ]
机构
[1] Bitlis Eren Univ, Elect Elect Engn Dept, TR-13000 Bitlis, Turkiye
关键词
Efficiency; Source-to-detector distance; Bias voltage; NaI(Tl); PEAK EFFICIENCY; CALIBRATION; CALCULATE;
D O I
10.1016/j.jrras.2023.100613
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
There are different types of radiation detectors (gas-filled, semiconductor, scintillator etc.) and various working principles (ionization, electron-hole pair production, excitation) used in radiation detection. It is important that any detector is selected according to its intended use and that the detector is operated under appropriate conditions. NaI(Tl) scintillation detectors are widely used in nuclear spectroscopic studies due to their known advantages. Prior to carrying out such studies, it is first necessary to know the response function of the detector against radiation under the expected operating conditions and to perform the appropriate calibrations. It is important that certain factors are optimized, such as the experimental setup (source-to-detector position, shielding, source activity etc.), gain, bias voltage, and shaping time, which can each significantly affect the response function. In addition, in computational studies based on experimentation, optimization is gain more significant since it is assumed that such experimental studies are carried out under optimum conditions. In this study, in order to determine the most suitable operating conditions for a 3 x 3 inch NaI(Tl) detector; a coaxial sample holder was manufactured to enable different source-to-detector distances (5-15 cm) to be tested, and spectra were then obtained using different bias voltages (750-850 V) and sources with different energies in the range of 81-1332 keV. Through the use of efficiency values obtained for each condition, line and 3D surface plots were drawn and the relations between efficiency and distance, energy and bias voltage examined. The results showed that the efficiency value had an exponentially decreasing characteristic that was dependent on the energy and source-detector distance, and had the highest value at a bias voltage of around 800 V.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] LOW-LEVEL ACTIVITY OF RADIUM 226 IN WATER MEASURED WITH A 3X3 INCH NAI(TL) CRYSTAL
    IRFAN, M
    READ, JH
    NUCLEAR INSTRUMENTS & METHODS, 1981, 179 (02): : 389 - 392
  • [2] A 3X3 CSI(TL) ARRAY AS AN EXAMPLE OF A SEGMENTED DETECTOR
    RUIZ, JA
    FERRERO, JL
    BERNABEU, G
    REGLERO, V
    SANCHEZ, F
    ASTROPHYSICAL JOURNAL SUPPLEMENT SERIES, 1994, 92 (02): : 659 - 662
  • [3] Variation of Energy Resolution with Distance for a NaI(Tl) Detector
    Akkurt, I.
    Arda, S. S.
    Gunoglu, K.
    ACTA PHYSICA POLONICA A, 2015, 128 (2B) : B422 - B423
  • [4] CALCULATED EFFICIENCIES OF A 3X3 IN NAI(TL) WELL-TYPE SCINTILLATION CRYSTAL
    VERHEIJKE, ML
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1962, 13 (OCT): : 583 - &
  • [5] Development of gamma spectroscopy employing NaI(Tl) detector 3 inch x 3 inch and readout electronic of flash-ADC/FPGA-based technology
    Vo Hong Hai
    Nguyen Quoc Hung
    Bui Tuan Khai
    KERNTECHNIK, 2015, 80 (02) : 180 - 183
  • [6] Evaluation the nonlinear response function of a 3x3 in NaI scintillation detector for PGNAA applications
    Hakimabad, Hashem Miri
    Panjeh, Hamed
    Vejdani-Noghreiyan, Afireza
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (08) : 918 - 926
  • [7] CALCULATED ABSOLUTE PHOTOPEAK EFFICIENCY VALUES FOR 3X3 IN NAI-DETECTOR WITH CYLINDRICAL SOURCE GEOMETRY
    RIEPPO, R
    BLOMSTER, K
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1976, 27 (07): : 365 - 367
  • [8] Experimental and simulated study of detector collimation for a portable 3'' x 3'' NaI(Tl) detector system for in-situ measurements
    Kiran, K. U.
    Ravindraswami, K.
    Eshwarappa, K. M.
    Somashekarappa, H. M.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2015, 8 (04) : 597 - 605
  • [9] ASSESSMENT OF DATA AND METHODS TO FORM RESPONSE FUNCTIONS OF A 3''0X3'' NAI(TL) DETECTOR
    MIURA, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 221 (03): : 603 - 608
  • [10] FAST CALIBRATION OF A FLAT, 3X3-INCH NAI(TL) DETECTOR FOR GAMMA-COUNTING AT VARIOUS GEOMETRIES BY USE OF A POINT-SOURCE CALIBRATION CURVE
    LEVINSON, S
    SHANI, G
    BERGMAN, S
    GILAD, Y
    GERMAN, U
    HEALTH PHYSICS, 1988, 54 (03): : 362 - 362