Optimization of 3x3 inch NaI(Tl) detector related to energy, distance and bias voltage

被引:13
|
作者
Kuluozturk, Muhammed Fatih [1 ]
机构
[1] Bitlis Eren Univ, Elect Elect Engn Dept, TR-13000 Bitlis, Turkiye
关键词
Efficiency; Source-to-detector distance; Bias voltage; NaI(Tl); PEAK EFFICIENCY; CALIBRATION; CALCULATE;
D O I
10.1016/j.jrras.2023.100613
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
There are different types of radiation detectors (gas-filled, semiconductor, scintillator etc.) and various working principles (ionization, electron-hole pair production, excitation) used in radiation detection. It is important that any detector is selected according to its intended use and that the detector is operated under appropriate conditions. NaI(Tl) scintillation detectors are widely used in nuclear spectroscopic studies due to their known advantages. Prior to carrying out such studies, it is first necessary to know the response function of the detector against radiation under the expected operating conditions and to perform the appropriate calibrations. It is important that certain factors are optimized, such as the experimental setup (source-to-detector position, shielding, source activity etc.), gain, bias voltage, and shaping time, which can each significantly affect the response function. In addition, in computational studies based on experimentation, optimization is gain more significant since it is assumed that such experimental studies are carried out under optimum conditions. In this study, in order to determine the most suitable operating conditions for a 3 x 3 inch NaI(Tl) detector; a coaxial sample holder was manufactured to enable different source-to-detector distances (5-15 cm) to be tested, and spectra were then obtained using different bias voltages (750-850 V) and sources with different energies in the range of 81-1332 keV. Through the use of efficiency values obtained for each condition, line and 3D surface plots were drawn and the relations between efficiency and distance, energy and bias voltage examined. The results showed that the efficiency value had an exponentially decreasing characteristic that was dependent on the energy and source-detector distance, and had the highest value at a bias voltage of around 800 V.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Optimization of 3x3 neuromorphic photonic network for programmable Boolean operations
    Marchisio, Andrea
    Cem, Ali
    Ding, Yunhong
    Curri, Vittorio
    Carena, Andrea
    Da Ros, Francesco
    Bardella, Paolo
    PHYSICS AND SIMULATION OF OPTOELECTRONIC DEVICES XXXII, 2024, 12880
  • [22] A LaBr3:Ce-NaI(Tl) Phoswich for X- and low energy γ-ray astronomy
    Mazumdar, I.
    Kumar, G. Anil
    Gothe, D. A.
    Manchanda, R. K.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (03): : 995 - 998
  • [23] LaBr3:Ce and NaI:Tl performance comparison for single photon emission detector
    Bettiol, M.
    Preziosi, E.
    Borrazzo, C.
    Polito, C.
    Cinti, M. N.
    Pellegrini, R.
    Pani, R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 912 : 154 - 157
  • [24] Performance Enhancement and Area Optimization Of 3x3 NoC Using Random Arbiter
    Swamy, Kendaganna S.
    Jatti, Anand
    Uma, B., V
    2015 IEEE INTERNATIONAL ADVANCE COMPUTING CONFERENCE (IACC), 2015, : 65 - 69
  • [25] Experimental response function of a 3 in x 3 in NaI(Tl) detector by inverse matrix method and effective atomic number of composite materials by gamma backscattering technique
    Kiran, K. U.
    Ravindraswami, K.
    Eshwarappa, K. M.
    Somashekarappa, H. M.
    APPLIED RADIATION AND ISOTOPES, 2016, 111 : 56 - 65
  • [26] A study of the effect of Al2O3 reflector on response function of NaI(Tl) detector
    Hoang Duc Tam
    Huynh Dinh Chuong
    Tran Thien Thanh
    Chau Van Tao
    RADIATION PHYSICS AND CHEMISTRY, 2016, 125 : 88 - 93
  • [27] Comparison of neutron capture spectra taken by a constellation Xe-110 detector and a 1aEuro3x1aEuro3 NaI(Tl) crystal
    Austin, R. A.
    Hooten, D.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 279 (02) : 395 - 404
  • [28] Design optimization of a truncated cone-shaped LaBr3:Ce/NaI:Tl phoswich detector based on GEANT4 simulation
    Li, R. P.
    Wang, H. D.
    Lu, Jingbin
    Li, Chengqian
    Situ, Zirui
    Qu, Huan
    AIP ADVANCES, 2023, 13 (01)
  • [29] The energy response of LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals for GECAM
    Feng, Pei-Yi
    Sun, Xi-Lei
    An, Zheng-Hua
    Deng, Yong
    Wang, Cheng-Er
    Jiang, Huang
    Li, Jun-Jie
    Zhang, Da-Li
    Li, Xin-Qiao
    Xiong, Shao-Lin
    Zheng, Chao
    Gong, Ke
    Yang, Sheng
    Liu, Xiao-Jing
    Gao, Min
    Wen, Xiang-Yang
    Liu, Ya-Qing
    Xu, Yan-Bing
    Zhao, Xiao-Yun
    Liu, Jia-Cong
    Zhang, Fan
    Lu, Hong
    NUCLEAR SCIENCE AND TECHNIQUES, 2024, 35 (02)
  • [30] The Comparison of Energy Resolution Fitting Functions for 1.5" NaI:Tl, CsI:Tl, LaBr3:Ce, and CeBr3 Scintillation Detectors
    Stribrnsky, Branislav
    Hinca, Robert
    APPLIED PHYSICS OF CONDENSED MATTER (APCOM 2021), 2021, 2411