Optimization of 3x3 inch NaI(Tl) detector related to energy, distance and bias voltage

被引:13
|
作者
Kuluozturk, Muhammed Fatih [1 ]
机构
[1] Bitlis Eren Univ, Elect Elect Engn Dept, TR-13000 Bitlis, Turkiye
关键词
Efficiency; Source-to-detector distance; Bias voltage; NaI(Tl); PEAK EFFICIENCY; CALIBRATION; CALCULATE;
D O I
10.1016/j.jrras.2023.100613
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
There are different types of radiation detectors (gas-filled, semiconductor, scintillator etc.) and various working principles (ionization, electron-hole pair production, excitation) used in radiation detection. It is important that any detector is selected according to its intended use and that the detector is operated under appropriate conditions. NaI(Tl) scintillation detectors are widely used in nuclear spectroscopic studies due to their known advantages. Prior to carrying out such studies, it is first necessary to know the response function of the detector against radiation under the expected operating conditions and to perform the appropriate calibrations. It is important that certain factors are optimized, such as the experimental setup (source-to-detector position, shielding, source activity etc.), gain, bias voltage, and shaping time, which can each significantly affect the response function. In addition, in computational studies based on experimentation, optimization is gain more significant since it is assumed that such experimental studies are carried out under optimum conditions. In this study, in order to determine the most suitable operating conditions for a 3 x 3 inch NaI(Tl) detector; a coaxial sample holder was manufactured to enable different source-to-detector distances (5-15 cm) to be tested, and spectra were then obtained using different bias voltages (750-850 V) and sources with different energies in the range of 81-1332 keV. Through the use of efficiency values obtained for each condition, line and 3D surface plots were drawn and the relations between efficiency and distance, energy and bias voltage examined. The results showed that the efficiency value had an exponentially decreasing characteristic that was dependent on the energy and source-detector distance, and had the highest value at a bias voltage of around 800 V.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] The energy response of LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals for GECAM
    Pei?Yi Feng
    Xi?Lei Sun
    Zheng?Hua An
    Yong Deng
    Cheng?Er Wang
    Huang Jiang
    Jun?Jie Li
    Da?Li Zhang
    Xin?Qiao Li
    Shao?Lin Xiong
    Chao Zheng
    Ke Gong
    Sheng Yang
    Xiao?Jing Liu
    Min Gao
    Xiang?Yang Wen
    Ya?Qing liu
    Yan?Bing Xu
    Xiao?Yun Zhao
    Jia?Cong Liu
    Fan Zhang
    Hong Lu
    Nuclear Science and Techniques, 2024, 35 (02) : 59 - 71
  • [32] Validation of a NaI(Tl) and LaBr3(Ce) detector's models via measurements and Monte Carlo simulations
    Mouhti, I
    Elanique, A.
    Messous, M. Y.
    Belhorma, B.
    Benahmed, A.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2018, 11 (04) : 335 - 339
  • [33] Performance profile and game-related statistics of FIBA 3x3 Basketball World Cup 2017
    Conte, Daniele
    Straigis, Eduardas
    Clemente, Filipe Manuel
    Gomez, Miguel-Angel
    Tessitore, Antonio
    BIOLOGY OF SPORT, 2019, 36 (02) : 149 - 154
  • [34] Noise Suppression of Frequency Transfer on Short-distance Optical Fiber Link Based on 3x3 Fiber Coupler
    Hu Zhenyuan
    Yue Yaoli
    Zhang Yanyan
    Gao Shuaihe
    Yang Xiguang
    Sui Ming
    Pan Zhibing
    Zhang Shougang
    Li Yang
    ACTA PHOTONICA SINICA, 2023, 52 (01)
  • [35] A SPECTROMETRIC METHOD FOR MEASURING INTENSITY OF NATURAL GAMMA EXPOSURE WITH AN EXAMINATION OF ANGULAR RESPONSE OF A NAI(TL) 3''X3'' CRYSTAL
    CARDINAL.A
    FRITTELL.L
    LEMBO, G
    MINERVA FISICONUCLEAR-GIORNALE DI FISICA SANITARIA PROTEZIONE CONTRO LE RADIZIONI, 1968, 12 (03): : 125 - &
  • [36] Scatter correction using a dual energy window technique for 3D PET with NaI(Tl) detectors
    Univ of Pennsylvania, Philadelphia, United States
    IEEE Nucl Sci Symp Med Imaging Conf, (2011-2018):
  • [37] Energy resolution of LaBr3:Ce in a phoswich configuration with CsI:Na and NaI:Tl scintillator crystals
    Hull, G.
    Genolini, B.
    Josselin, M.
    Matea, I.
    Peyre, J.
    Pouthas, J.
    Zerguerras, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 : 350 - 353
  • [38] Energy-based scatter correction for 3-D PET scanners using NaI(Tl) detectors
    Adam, LE
    Karp, JS
    Freifelder, R
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 513 - 521
  • [39] TESTING OF THE PARIS LaBr3-NaI PHOSWICH DETECTOR WITH HIGH ENERGY GAMMA-RAYS
    Zieblinski, M.
    Jastrzab, M.
    Dokania, Neha
    Nanal, V.
    Brambilla, S.
    Bednarczyk, P.
    Ciemala, M.
    Dutkiewicz, E.
    Kmiecik, M.
    Krzysiek, M.
    Lekki, J.
    Maj, A.
    Szklarz, Z.
    Wasilewska, B.
    Dudelo, M.
    Hadynska-Klek, K.
    Napiorkowski, P.
    Genolini, B.
    Schmitt, Ch
    Catford, W.
    Nakhostin, M.
    Yavuzkanat, N.
    Dorvaux, O.
    Pillay, R. G.
    Pose, M. S.
    Mishra, S.
    Mathimalar, S.
    Singh, V.
    Katyan, N.
    Chakrabarty, D. R.
    Datar, V. M.
    Kumar, Suresh
    Mishra, G.
    Mukhopadhyay, S.
    Pandit, D.
    Erturk, S.
    ACTA PHYSICA POLONICA B, 2013, 44 (03): : 651 - 656
  • [40] Characterization of CeBr 3 and NaI (Tl) based detector modules with readout using an array of Silicon Photomultiplier for the future space exploration programs
    Goyal, Shiv Kumar
    Naik, Amisha P.
    Sharma, Piyush
    Verma, Abhishek J.
    Chotaliya, Nupoor A.
    Soni, Mansi M.
    ADVANCES IN SPACE RESEARCH, 2024, 73 (09) : 4878 - 4891