摘要
The INTEGRAL imager will use a novel design, which consists of three layers of about 3000 small CsI(Tl) scintillation elements each. We illustrate the operation of such a design by means of nine CsI(Tl) bars forming a 3 X 3 array. Several collimated radioactive sources were used to obtain experimental data showing different kinds of events and modes of operation. One of the array bars was irradiated with high-energy protons in order to study modes of background rejection in the imager. A comparison with Monte Carlo simulation results is also presented.
引用
收藏
页码:659 / 662
页数:4
相关论文
共 50 条
  • [1] A 3X3 PYROELECTRIC DETECTOR ARRAY WITH IMPROVED SENSOR TECHNOLOGY
    VONMUNCH, W
    NAGELE, M
    WOHL, G
    PLOSS, B
    RUPPEL, W
    SENSORS AND ACTUATORS A-PHYSICAL, 1994, 41 (1-3) : 156 - 160
  • [2] Optimization of 3x3 inch NaI(Tl) detector related to energy, distance and bias voltage
    Kuluozturk, Muhammed Fatih
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (03)
  • [3] Fabrication of a 3x3 neutron pinhole array
    Day, Robert D.
    Brooks, Paul M.
    Edwards, Randall L.
    Garcia, Felix P.
    Grim, Gary P.
    Nobile, Arthur, Jr.
    Schmidt, Derek W.
    Snow, Ronald C.
    Valdez, Adelaida C.
    FUSION SCIENCE AND TECHNOLOGY, 2007, 51 (04) : 776 - 781
  • [4] Development of 8×8 CsI(Tl) array detector
    Yao, Xiang-Wu
    Yang, Yan-Yun
    Wang, Jian-Song
    Huang, Mei-Rong
    Gao, Qi
    Guo, Zhong-Yan
    Xiao, Guo-Qing
    Xu, Hu-Shan
    Hu, Zheng-Guo
    Yu, Yu-Hong
    Qiu, Hao
    Yan, Xin-Shuai
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (03): : 358 - 361
  • [5] 3X3 ARRAY OF INTRINSIC GERMANIUM DETECTORS FOR RADIONUCLIDE SCANNING
    PATTON, JA
    PRICE, RR
    BRILL, AB
    PEHL, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (01): : 109 - 110
  • [6] Development of a 3x3 micromachined millimeter wave SIS imaging array
    deLange, G
    Rahman, A
    Duerr, E
    Hu, Q
    Huang, H
    Lichtenberger, AW
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) : 3593 - 3596
  • [7] A 3X3 SILICON DRIFT CHAMBER ARRAY FOR APPLICATION IN AN ELECTRONIC COLLIMATOR
    KUYKENS, HJP
    AUDET, SA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 570 - 574
  • [8] Underwater Radiation Fields of Magnetic Dipole Array with 3x3 elements
    Liu, Xiangpeng
    Zheng, Kuisong
    Mu, Zongmin
    Liu, Yang
    PROCEEDINGS OF THE 2016 11TH INTERNATIONAL SYMPOSIUM ON ANTENNAS, PROPAGATION AND EM THEORY (ISAPE), 2016, : 72 - 74
  • [9] CALCULATED EFFICIENCIES OF A 3X3 IN NAI(TL) WELL-TYPE SCINTILLATION CRYSTAL
    VERHEIJKE, ML
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1962, 13 (OCT): : 583 - &
  • [10] CsI(Tl)-pin detector as an element of a charged particle multiplicity filter array
    Bandyopadhyay, D
    Basu, SK
    RADIATION PHYSICS AND CHEMISTRY, 1998, 51 (4-6) : 457 - 458