Variation of Energy Resolution with Distance for a NaI(Tl) Detector

被引:0
|
作者
Akkurt, I. [1 ]
Arda, S. S. [1 ]
Gunoglu, K. [1 ]
机构
[1] Suleyman Demirel Univ, Dept Phys, TR-32200 Isparta, Turkey
关键词
D O I
10.12693/APhysPolA.128.B-422
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
As the nuclear radiation has started to be used in a variety of different fields, it is important to be protected from it, and thus the radiation measurement becomes vital. The quality of the performance of a detection system, used for the energy measurements, is important. It is characterized by the width of the pulse-height distribution, obtained for the particles of the same energy (monoenergetic source). The energy spectrum of a radiation source depends on the type and energy of the incident particle and the type of the detector. In this work the energy resolution of a 3 '' x 3 '' NaI(Tl) detector has been measured for photon energies of 511, 662, 835, 1173, 1275, and 1332 keV, and its variation with the detector-source distance was investigated. The energy resolution of a detector system is obtained from the peak full width at one-half of the maximum height (FWHM) of a single peak (for a particular energy) as a function of detector-source distance. It was found that the energy resolution has decreased with the increasing distance.
引用
收藏
页码:B422 / B423
页数:2
相关论文
共 50 条
  • [1] Determination of energy resolution for a NaI(Tl) detector modeled with FLUKA code
    Demir, Nilgun
    Kuluozturk, Zehra Nur
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2021, 53 (11) : 3759 - 3763
  • [2] NaI(Tl) electron energy resolution
    Mengesha, W
    Valentine, JD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 486 (1-2): : 374 - 380
  • [3] DEVELOPMENT OF A NAI(TL) DETECTOR WITH SUPERIOR PHOTON ENERGY RESOLUTION FOR USE ABOVE 100 MEV
    MILLER, JP
    AUSTIN, EJ
    BOOTH, EC
    GALL, KP
    MCINTYRE, EK
    WHITEHOUSE, DA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 270 (2-3): : 431 - 436
  • [4] Dependence of NaI(Tl) detector intrinsic efficiency on source-detector distance, energy and off-axis distance: Their implications for radioactivity measurements
    F. O. Ogundare
    E. O. Oniya
    F. A. Balogun
    Pramana, 2008, 70 : 863 - 874
  • [5] Dependence of NaI(Tl) detector intrinsic efficiency on source-detector distance, energy and off-axis distance: Their implications for radioactivity measurements
    Ogundare, F. O.
    Oniya, E. O.
    Balogun, F. A.
    PRAMANA-JOURNAL OF PHYSICS, 2008, 70 (05): : 863 - 874
  • [6] Benchmarking NaI(Tl) electron energy resolution measurements
    Mengesha, W
    Valentine, JD
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2420 - 2426
  • [7] ENERGY DEPENDENCE OF INTRINSIC RESOLUTION OF NAI(TL) CRYSTALS
    MOKHIR, EP
    KRAVCHEN.NG
    TSIRLIN, YA
    SULYGA, VA
    SOVIET ATOMIC ENERGY, 1968, 24 (05): : 598 - &
  • [8] DEVELOPMENT OF A NaI(Tl) DETECTOR WITH SUPERIOR PHOTON ENERGY RESOLUTION FOR USE ABOVE 100 MeV.
    Miller, J.P.
    Austin, E.J.
    Booth, E.C.
    Gall, K.P.
    McIntyre, E.K.
    Whitehouse, D.A.
    Nuclear instruments and methods in physics research, 1988, A270 (2-3): : 431 - 436
  • [9] Optimization of 3x3 inch NaI(Tl) detector related to energy, distance and bias voltage
    Kuluozturk, Muhammed Fatih
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (03)
  • [10] Full-Energy peak efficiency of an NaI(Tl) detector with coincidence summing correction showing the effect of the source-to-detector distance
    El-Khatib, Ahmed M.
    Salem, Bohaysa A.
    Badawi, Mohamed S.
    Gouda, Mona M.
    Thabet, Abouzeid A.
    Abbas, Mahmoud I.
    CHINESE JOURNAL OF PHYSICS, 2017, 55 (02) : 478 - 489