Analysis of Voltage Dip Impact on Doubly Fed Induction Generator under Dynamic Conditions

被引:1
|
作者
Zergaw, Kidist Berhane [1 ]
Tuka, Milkias Berhanu [1 ]
机构
[1] Adama Sci & Technol Univ, Elect Power & Control Engn Dept, Adama, Ethiopia
来源
关键词
Voltage dip; Adaptive neuro-fuzzy inference system; Crowbar; Doubly fed induction generator; Low voltage ride through; CAPABILITY ENHANCEMENT; WIND; DEVICES; RIDE;
D O I
10.5455/jjee.204-1669034454
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Doubly Fed Induction Generator (DFIG) is the most widely employed generator in the Wind Energy Conversion Systems (WECS) for the production of electricity. However, despite all of its various advantages, it is extremely vulnerable to grid faults such as voltage dip since its stator is directly coupled to the grid. A voltage dip problem is one the main issues among the power quality concerns. This fault causes the flow of excessive current across both the stator and the rotor terminals, which may lead to serious damage to the generator, power converters, and DC Link capacitor. On the other hand, the current Grid Codes (GC) requires the system to stay connected to the grid during this fault condition and support it in healing its nominal voltage. This capacity of the system is known as the Low Voltage Ride Through (LVRT) capacity. For the system to achieve such capacity, appropriate protection mechanisms or controlling strategies must be utilized. Therefore, in this paper, the crowbar protection technique, PI controller, and the Adaptive Neuro-Fuzzy Inference System (ANFIS) controller are employed. Furthermore, the performance of the system employing PI, crowbar, and ANFIS is analyzed and compared under grid fault conditions, i.e., a voltage dip with a magnitude of 0.1 pu (worst case) using MATLAB/Simulink software and based on actual data obtained from Adama II wind farm. The obtained results unveil that the settling time of ANFIS for controlling the rotor currents in d and q axes (idr and iqr) and DC link voltage is 3.6 s, 3.57 s, and 3.4 s, respectively. On the other hand, the settling times of the PI controller for controlling the rotor currents in d and q axes and the DC link voltage are found to be 4 s, 3.91 s, and 45.2 s, respectively, while the crowbar protection technique's settling times are found to be 4 s, 6 s, and 4.9 s, respectively. It is evident from the aforesaid results that the ANFIS controller provides the best performance of the three strategies since it allows both the rotor currents and the DC link voltage to return to their steady state values faster than the other two techniques, employed in this investigation.
引用
收藏
页码:338 / 356
页数:19
相关论文
共 50 条
  • [31] Doubly Fed Induction Generator Subject to Symmetrical Voltage Sags
    Rolan, Alejandro
    Corcoles, Felipe
    Pedra, Joaquin
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (04) : 1219 - 1229
  • [32] Understanding the Doubly Fed Induction Generator During Voltage Dips
    Marques, G. D.
    Sousa, Duarte M.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2012, 27 (02) : 421 - 431
  • [33] Modified voltage oriented control of brushless doubly fed induction generator based drivetrain under grid imbalance conditions
    Dauksha, Gennadiy
    Iwanski, Grzegorz
    2019 FOURTEENTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2019,
  • [34] Synchronous Compensator Based on Doubly Fed Induction Generator to Improve the Power Quality under Unbalanced Grid Voltage Conditions
    Silva, Paulo H. P.
    Lima, Francisco Kleber de A.
    Fonseca, Jean M. L.
    Branco, Carlos Gustavo C.
    Schmidlin Junior, Celso R.
    ENERGIES, 2018, 11 (10)
  • [35] Magnetostriction Analysis on Doubly Fed Induction Generator under normal and Low Voltage Ride through (LVRT) Condition
    Nikita, T.
    Manickavasagam, K.
    Sachin, S.
    PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON TECHNOLOGICAL ADVANCEMENTS IN POWER AND ENERGY (TAP ENERGY): EXPLORING ENERGY SOLUTIONS FOR AN INTELLIGENT POWER GRID, 2017,
  • [36] Analysis of Doubly Fed Induction Generator Dynamic Action to Power Angle Oscillation
    Niu, Zihua
    Li, Gengyin
    Zhou, Ming
    Wei, Junqiang
    2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [37] Analysis and comparison of dynamic models for the doubly fed induction generator wind turbine
    Key Laboratory of Power System Protection and Dynamic Security Monitoring and Control Under, North China Electric Power University, Baoding 071003, China
    Dianli Xitong Zidonghue, 2006, 13 (22-27):
  • [38] Investigation of Doubly Fed Induction Generator Behavior Under Symmetrical and Asymmetrical Fault Conditions
    Tamvada, Karthik
    Umashankar, S.
    Sanjeevikumar, P.
    ADVANCES IN SYSTEMS, CONTROL AND AUTOMATION, 2018, 442 : 347 - 353
  • [39] Improved active power dynamic response of voltage-controlled doubly fed induction generator
    Xie, Zhen
    Gao, Xiang
    Li, Zhe
    Ma, Mingyao
    Zhang, Xing
    IET ELECTRIC POWER APPLICATIONS, 2021, 15 (12) : 1588 - 1603
  • [40] Dynamic behavior of the doubly fed induction generator during three-phase voltage dips
    Lopez, Jesus
    Sanchis, Pablo
    Roboam, Xavier
    Marroyo, Luis
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (03) : 709 - 717