Analysis of Voltage Dip Impact on Doubly Fed Induction Generator under Dynamic Conditions

被引:1
|
作者
Zergaw, Kidist Berhane [1 ]
Tuka, Milkias Berhanu [1 ]
机构
[1] Adama Sci & Technol Univ, Elect Power & Control Engn Dept, Adama, Ethiopia
来源
关键词
Voltage dip; Adaptive neuro-fuzzy inference system; Crowbar; Doubly fed induction generator; Low voltage ride through; CAPABILITY ENHANCEMENT; WIND; DEVICES; RIDE;
D O I
10.5455/jjee.204-1669034454
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Doubly Fed Induction Generator (DFIG) is the most widely employed generator in the Wind Energy Conversion Systems (WECS) for the production of electricity. However, despite all of its various advantages, it is extremely vulnerable to grid faults such as voltage dip since its stator is directly coupled to the grid. A voltage dip problem is one the main issues among the power quality concerns. This fault causes the flow of excessive current across both the stator and the rotor terminals, which may lead to serious damage to the generator, power converters, and DC Link capacitor. On the other hand, the current Grid Codes (GC) requires the system to stay connected to the grid during this fault condition and support it in healing its nominal voltage. This capacity of the system is known as the Low Voltage Ride Through (LVRT) capacity. For the system to achieve such capacity, appropriate protection mechanisms or controlling strategies must be utilized. Therefore, in this paper, the crowbar protection technique, PI controller, and the Adaptive Neuro-Fuzzy Inference System (ANFIS) controller are employed. Furthermore, the performance of the system employing PI, crowbar, and ANFIS is analyzed and compared under grid fault conditions, i.e., a voltage dip with a magnitude of 0.1 pu (worst case) using MATLAB/Simulink software and based on actual data obtained from Adama II wind farm. The obtained results unveil that the settling time of ANFIS for controlling the rotor currents in d and q axes (idr and iqr) and DC link voltage is 3.6 s, 3.57 s, and 3.4 s, respectively. On the other hand, the settling times of the PI controller for controlling the rotor currents in d and q axes and the DC link voltage are found to be 4 s, 3.91 s, and 45.2 s, respectively, while the crowbar protection technique's settling times are found to be 4 s, 6 s, and 4.9 s, respectively. It is evident from the aforesaid results that the ANFIS controller provides the best performance of the three strategies since it allows both the rotor currents and the DC link voltage to return to their steady state values faster than the other two techniques, employed in this investigation.
引用
收藏
页码:338 / 356
页数:19
相关论文
共 50 条
  • [41] Improving Analysis of Low Voltage Ride Through Capability in Turbines Connected to The Brushless Doubly Fed Induction Generator (BDFIG) under Fault Conditions
    Alizadeh, Maryam
    Ghazi, Reza
    Haghani, Ehsan Erfani
    Rad, Mohammad Esmaeili
    34TH INTERNATIONAL POWER SYSTEM CONFERENCE (PSC2019), 2019, : 655 - 661
  • [42] Simulation and Analysis on Low Voltage Ride Through of Doubly-Fed Induction Generator
    Shi, Lei
    Chen, Ning
    Zhu, Lingzhi
    Chen, Hu
    Liu, Haoming
    2011 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2011,
  • [43] Short circuit analysis of a doubly-fed induction generator and the impact on generator circuit breakers
    Karthik Reddy Venna
    Hong Urbanek
    Alois Lechner
    e & i Elektrotechnik und Informationstechnik, 2023, 140 : 162 - 167
  • [44] Ride-Through Control of a Doubly Fed Induction Generator Under Unbalanced Voltage Sags
    Gomis-Bellmunt, Oriol
    Junyent-Ferre, Adria
    Sumper, Andreas
    Bergas-Jane, Joan
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (04) : 1036 - 1045
  • [45] Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips
    Lopez, Jesus
    Gubia, Eugenio
    Olea, Eneko
    Ruiz, Josu
    Marroyo, Luis
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (10) : 4246 - 4254
  • [46] Short circuit analysis of a doubly-fed induction generator and the impact on generator circuit breakers
    Venna, Karthik Reddy
    Urbanek, Hong
    Lechner, Alois
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2023, 140 (01): : 162 - 167
  • [47] Improved Grid Synchronization Control of Doubly Fed Induction Generator Under Unbalanced Grid Voltage
    Chen, Si Zhe
    Cheung, Norbert C.
    Zhang, Yun
    Zhang, Miao
    Tang, Xiong Min
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (03) : 799 - 810
  • [48] Stability of doubly-fed induction generator under stator voltage orientated vector control
    Chondrogionnis, S.
    Barnes, M.
    IET RENEWABLE POWER GENERATION, 2008, 2 (03) : 170 - 180
  • [49] Dynamic modeling of doubly fed induction generator wind turbines
    Ekanayake, JB
    Holdsworth, L
    Wu, XG
    Jenkins, N
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (02) : 803 - 809
  • [50] A Dynamic LVRT Solution for Doubly-Fed Induction Generator
    Abdel-Baqi, Omar
    Nasiri, Adel
    IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, : 761 - +