Analysis of Voltage Dip Impact on Doubly Fed Induction Generator under Dynamic Conditions

被引:1
|
作者
Zergaw, Kidist Berhane [1 ]
Tuka, Milkias Berhanu [1 ]
机构
[1] Adama Sci & Technol Univ, Elect Power & Control Engn Dept, Adama, Ethiopia
来源
关键词
Voltage dip; Adaptive neuro-fuzzy inference system; Crowbar; Doubly fed induction generator; Low voltage ride through; CAPABILITY ENHANCEMENT; WIND; DEVICES; RIDE;
D O I
10.5455/jjee.204-1669034454
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Doubly Fed Induction Generator (DFIG) is the most widely employed generator in the Wind Energy Conversion Systems (WECS) for the production of electricity. However, despite all of its various advantages, it is extremely vulnerable to grid faults such as voltage dip since its stator is directly coupled to the grid. A voltage dip problem is one the main issues among the power quality concerns. This fault causes the flow of excessive current across both the stator and the rotor terminals, which may lead to serious damage to the generator, power converters, and DC Link capacitor. On the other hand, the current Grid Codes (GC) requires the system to stay connected to the grid during this fault condition and support it in healing its nominal voltage. This capacity of the system is known as the Low Voltage Ride Through (LVRT) capacity. For the system to achieve such capacity, appropriate protection mechanisms or controlling strategies must be utilized. Therefore, in this paper, the crowbar protection technique, PI controller, and the Adaptive Neuro-Fuzzy Inference System (ANFIS) controller are employed. Furthermore, the performance of the system employing PI, crowbar, and ANFIS is analyzed and compared under grid fault conditions, i.e., a voltage dip with a magnitude of 0.1 pu (worst case) using MATLAB/Simulink software and based on actual data obtained from Adama II wind farm. The obtained results unveil that the settling time of ANFIS for controlling the rotor currents in d and q axes (idr and iqr) and DC link voltage is 3.6 s, 3.57 s, and 3.4 s, respectively. On the other hand, the settling times of the PI controller for controlling the rotor currents in d and q axes and the DC link voltage are found to be 4 s, 3.91 s, and 45.2 s, respectively, while the crowbar protection technique's settling times are found to be 4 s, 6 s, and 4.9 s, respectively. It is evident from the aforesaid results that the ANFIS controller provides the best performance of the three strategies since it allows both the rotor currents and the DC link voltage to return to their steady state values faster than the other two techniques, employed in this investigation.
引用
收藏
页码:338 / 356
页数:19
相关论文
共 50 条
  • [21] Passivity-Based Control of a Doubly Fed Induction Generator System under Unbalanced Grid Voltage Conditions
    Huang, Jiawei
    Wang, Honghua
    Wang, Chong
    ENERGIES, 2017, 10 (08):
  • [22] Dynamic Behavior of Doubly Fed Induction Generator Wind Turbines under Three-phase Voltage Dips
    Peng, Ling
    Li, Yongdong
    Francois, Bruno
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1376 - +
  • [23] Dynamic Control of the Brushless Doubly Fed Induction Generator Under Unbalanced Operation
    Shao, Shiyi
    Long, Teng
    Abdi, Ehsan
    McMahon, Richard A.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (06) : 2465 - 2476
  • [24] Analysis and Control of Doubly Fed Induction Generator for Zero Voltage Ride Through
    Tang, Haiyan
    Chang, Yuanzhu
    Chi, Yongning
    Wang, Bo
    Li, Yan
    Hu, Jiabing
    2016 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2016), 2016,
  • [25] Simulation Study on Permanent Magnet Doubly Fed Induction Generators Under Grid Voltage Dip
    Diao, Tongshan
    Yan, Zhiguo
    Wang, Lianfei
    Liu, Jiahe
    Hou, Dongdong
    Song, Ningran
    2019 22ND INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2019), 2019, : 1277 - 1281
  • [26] Wind turbines based on doubly fed induction generator under asymmetrical voltage dips
    Lopez, Jesus
    Gubia, Eugenio
    Sanchis, Pablo
    Roboam, Xavier
    Marroyo, Luis
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (01) : 321 - 330
  • [27] Comparison between Modifications of SFOC and DPC in Control of Grid-Connected Doubly Fed Induction Generator under Unbalanced Voltage Dip
    Truc Pham-Dinh
    Hai Nguyen-Thanh
    Uchida, Kenko
    Nguyen Gia Minh Thao
    2013 PROCEEDINGS OF SICE ANNUAL CONFERENCE (SICE), 2013, : 2581 - 2588
  • [28] Direct Power Control of Doubly Fed Induction Generator Under Distorted Grid Voltage
    Nian, Heng
    Song, Yipeng
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (02) : 894 - 905
  • [29] The Modified Sliding Mode Control of a Doubly Fed Induction Generator for Wind Energy Conversion During a Voltage Dip
    Elaimani, Hind
    Essadki, Ahmed
    ELmouhi, Noureddine
    Chakib, Rachid
    2019 INTERNATIONAL CONFERENCE ON WIRELESS TECHNOLOGIES, EMBEDDED AND INTELLIGENT SYSTEMS (WITS), 2019,
  • [30] Power and voltage Smooth control of doubly fed induction generator
    Ma, An-ren
    Wang, Cai-xia
    Zhou, Zhi-wen
    Wu, Tao
    CURRENT DEVELOPMENT OF MECHANICAL ENGINEERING AND ENERGY, PTS 1 AND 2, 2014, 494-495 : 1829 - 1832