No gadolinium K-edge detected on the first clinical photon-counting computed tomography scanner

被引:3
|
作者
Baubeta, Erik [1 ,2 ,5 ]
Laurin Gadsboll, Eva [1 ]
Will, Leon [1 ]
Holmquist, Fredrik [1 ,3 ]
Aurumskjold, Marie-Louise [4 ]
机构
[1] Skane Univ Hosp, Dept Imaging & Funct Med, Lund, Sweden
[2] Lund Univ, Dept Translat Med, Diagnost Radiol, Malmo, Sweden
[3] Lund Univ, Dept Clin Sci, Diagnost Radiol, Lund, Sweden
[4] Lund Univ, Dept Clin Sci Malmo, Med Radiat Phys, Dept Clin Sci, Lund, Sweden
[5] Skane Univ Hosp, Dept Imaging & Funct Med, S-22185 Lund, Sweden
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2024年 / 25卷 / 04期
关键词
computed tomography; EICT; energy integrated computed tomography; gadolinium contrast agent; iodine contrast agent; K-edge; material decomposition; PCCT; photon counting computed tomography; CONTRAST-MEDIA; CT;
D O I
10.1002/acm2.14324
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aimed to elucidate whether gadolinium contrast in clinically relevant doses can be used with photon-counting computed tomography (PCCT) as an alternative contrast agent in clinical applications. Material/methods: A CTDI phantom with 3D printed rods filled with different concentrations of gadolinium and iodine contrast was scanned in a PCCT and an energy-integrated computed tomography (EICT). Attenuation values at different monoenergetic steps were extracted for each contrast concentration. Results: For PCCT, gadolinium reached an attenuation >100 HU (103 HU) at 40 keV with a concentration 5 mmol/L whereas the same level was reached at 50 keV (118 HU) for 10 mmol/L and 90 keV (114 HU) for 25 mmol/L. For iodine, the same level of attenuation was reached at 100 keV (106 HU) with a concentration 8.75 mg I/mL. For EICT the lowest gadolinium contrast concentration needed to reach >100 HU (108 HU) was 10 mmol/L at 50 keV. For 25 mmol/L 100 HU was reached at 100 keV. For iodine contrast 108 HU was reached at 110 keV for 8.75 mg I/mL. Conclusion: No K-edge potential or difference in attenuation curves between iodine and gadolinium contrast is detected on the first clinical available PCCT. Clinically relevant attenuation levels were barely achieved in this setting with gadolinium concentrations approved for human use. The results of this study suggest that, given current scanning technology, gadolinium is not a clinically useful contrast agent for computed tomography because no K-edge was detected.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Photon-Counting Detectors in Computed Tomography: A Review
    Gomes, Muriel Jeremia
    Manakkal, Jaseemudheen M.
    JOURNAL OF HEALTH AND ALLIED SCIENCES NU, 2023, 13 (02): : 147 - 152
  • [22] In Vivo Molecular K-Edge Imaging of Atherosclerotic Plaque Using Photon-counting CT
    Si-Mohamed, Salim A.
    Sigovan, Monica
    Hsu, Jessica C.
    Tatard-Leitman, Valerie
    Chalabreysse, Lara
    Naha, Pratap C.
    Garrivier, Thibaut
    Dessouky, Riham
    Carnaru, Miruna
    Boussel, Loic
    Cormode, David P.
    Douek, Philippe C.
    RADIOLOGY, 2021, 300 (01) : 98 - 107
  • [23] The Feasibility of Accurate Stent Visualization With Photon-Counting Detector CT and K-Edge Imaging
    Richtsmeier, Devon
    Rodesch, Pierre-Antoine
    Iniewski, Kris
    Siu, William
    Bazalova-Carter, Magdalena
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2023, 7 (07) : 712 - 718
  • [24] Sensitivity of Photon-Counting K-Edge Imaging: Dependence on Atomic Number and Object Size
    Roessl, Ewald
    Brendel, Bernhard
    Schlomka, Jens-Peter
    Thran, Axel
    Proksa, Roland
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3291 - 3296
  • [25] Energy-Resolved Photon-Counting X-Ray Imaging Arrays for Clinical K-Edge CT
    Barber, William C.
    Nygard, Einar
    Wessel, Jan C.
    Malakhov, Nail
    Wawrzyniak, Gregor
    Hartsough, Neal E.
    Gandhi, Thulasi
    Iwanczyk, Jan S.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4441 - 4446
  • [26] Evaluation of spectral photon counting computed tomography K-edge imaging for determination of gold nanoparticle biodistribution in vivo
    Si-Mohamed, Salim
    Cormode, David P.
    Bar-Ness, Daniel
    Sigovan, Monica
    Naha, Pratap C.
    Langlois, Jean-Baptiste
    Chalabreysse, Lara
    Coulon, Philippe
    Blevis, Ira
    Roessl, Ewald
    Erhard, Klaus
    Boussel, Loic
    Douek, Philippe
    NANOSCALE, 2017, 9 (46) : 18246 - 18257
  • [27] Feasibility of Photon-counting K-edge Imaging in X-ray and Computed Tomographic Systems: Monte Carlo Simulation Studies
    Lee, Seung-Wan
    Choi, Yu-Na
    Cho, Hyo-Min
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (04) : 2833 - 2839
  • [28] Photon-Counting Computed Tomography in Atherosclerotic Plaque Characterization
    Cau, Riccardo
    Saba, Luca
    Balestrieri, Antonella
    Meloni, Antonella
    Mannelli, Lorenzo
    La Grutta, Ludovico
    Bossone, Eduardo
    Mantini, Cesare
    Politi, Carola
    Suri, Jasjit S.
    Cavaliere, Carlo
    Punzo, Bruna
    Maffei, Erica
    Cademartiri, Filippo
    DIAGNOSTICS, 2024, 14 (11)
  • [29] New contrast agents for photon-counting computed tomography
    Sawall, Stefan
    RADIOLOGIE, 2023, 63 (07): : 507 - 512
  • [30] CT technology: photon-counting detector computed tomography
    Layer, Yannik Christian
    Kravchenko, Dmitrij
    Dell, Tatjana
    Kuetting, Daniel
    RADIOLOGIE, 2023, 63 (07): : 497 - 506