Evaluation of spectral photon counting computed tomography K-edge imaging for determination of gold nanoparticle biodistribution in vivo

被引:96
|
作者
Si-Mohamed, Salim [1 ,2 ]
Cormode, David P. [3 ]
Bar-Ness, Daniel [2 ]
Sigovan, Monica [1 ,2 ]
Naha, Pratap C. [3 ]
Langlois, Jean-Baptiste [4 ]
Chalabreysse, Lara [5 ]
Coulon, Philippe [6 ]
Blevis, Ira [7 ]
Roessl, Ewald [8 ]
Erhard, Klaus [8 ]
Boussel, Loic [1 ,2 ]
Douek, Philippe [1 ,2 ]
机构
[1] CHU Lyon, Radiol Dept, Lyon, France
[2] Univ Lyon1 Claude Bernard, UMR 5220, CREATIS, INSERM,CNRS,U1044, Lyon, France
[3] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[4] CERMEP Imagerie Vivant, Lyon, France
[5] CHU Lyon, Pathol Dept, Lyon, France
[6] Philips, CT Clin Sci, Suresnes, France
[7] Philips, Global Adv Technol, CT, Haifa, Israel
[8] Philips GmbH Innovat Technol, Res Labs, Hamburg, Germany
关键词
RAY CONTRAST AGENT; DUAL-ENERGY; MULTIENERGY CT; IODINE; CANCER; RADIOTHERAPY; NANOBEACONS; FEASIBILITY; TANTALUM; LIVER;
D O I
10.1039/c7nr01153a
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Spectral photon counting computed tomography (SPCCT) is an emerging medical imaging technology. SPCCT scanners record the energy of incident photons, which allows specific detection of contrast agents due to measurement of their characteristic X-ray attenuation profiles. This approach is known as K-edge imaging. Nanoparticles formed from elements such as gold, bismuth or ytterbium have been reported as potential contrast agents for SPCCT imaging. Furthermore, gold nanoparticles have many applications in medicine, such as adjuvants for radiotherapy and photothermal ablation. In particular, longitudinal imaging of the biodistribution of nanoparticles would be highly attractive for their clinical translation. We therefore studied the capabilities of a novel SPCCT scanner to quantify the biodistribution of gold nanoparticles in vivo. PEGylated gold nanoparticles were used. Phantom imaging showed that concentrations measured on gold images correlated well with known concentrations (slope = 0.94, intercept = 0.18, RMSE = 0.18, R-2 = 0.99). The SPCCT system allowed repetitive and quick acquisitions in vivo, and follow-up of changes in the AuNP biodistribution over time. Measurements performed on gold images correlated with the inductively coupled plasma-optical emission spectrometry (ICP-OES) measurements in the organs of interest (slope = 0.77, intercept = 0.47, RMSE = 0.72, R-2 = 0.93). TEM results were in agreement with the imaging and ICP-OES in that much higher concentrations of AuNPs were observed in the liver, spleen, bone marrow and lymph nodes (mainly in macrophages). In conclusion, we found that SPCCT can be used for repetitive and non-invasive determination of the biodistribution of gold nanoparticles in vivo.
引用
收藏
页码:18246 / 18257
页数:12
相关论文
共 50 条
  • [1] Evaluation of gold K-edge imaging using spectral computed tomography with a photon-counting detector: A Monte Carlo simulation study
    Kang, Sooncheol
    Eom, Jisoo
    Kim, Burnyoung
    Lee, Seungwan
    OPTIK, 2017, 140 : 253 - 260
  • [2] K-edge spectral computed tomography with a photon counting detector and discrete reconstruction
    Brun, Francesco
    Di Trapani, Vittorio
    Dreossi, Diego
    Longo, Renata
    Delogu, Pasquale
    Rigon, Luigi
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 5245 - 5248
  • [3] Quantitative Spectral K-Edge Imaging in Preclinical Photon-Counting X-Ray Computed Tomography
    de Vries, Anke
    Roessl, Ewald
    Kneepkens, Esther
    Thran, Axel
    Brendel, Bernhard
    Martens, Gerhard
    Proska, Roland
    Nicolay, Klaas
    Gruell, Holger
    INVESTIGATIVE RADIOLOGY, 2015, 50 (04) : 297 - 304
  • [4] K-Edge Imaging Using a Gold Nanoparticle Contrast Agent and a CT System with Photon Counting Detectors
    Alivov, Y.
    Le, H.
    Molloi, S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [5] Sensitivity of Photon-Counting Based K-Edge Imaging in X-ray Computed Tomography
    Roessl, Ewald
    Brendel, Bernhard
    Engel, Klaus-Juergen
    Schlomka, Jens-Peter
    Thran, Axel
    Proksa, Roland
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (09) : 1678 - 1690
  • [6] Liquid Embolic Agents in Spectral X-Ray Photon-Counting Computed Tomography using Tantalum K-Edge Imaging
    Isabelle Riederer
    Daniel Bar-Ness
    Melanie A. Kimm
    Salim Si-Mohamed
    Peter B. Noël
    Ernst J. Rummeny
    Philippe Douek
    Daniela Pfeiffer
    Scientific Reports, 9
  • [7] Liquid Embolic Agents in Spectral X-Ray Photon-Counting Computed Tomography using Tantalum K-Edge Imaging
    Riederer, Isabelle
    Bar-Ness, Daniel
    Kimm, Melanie A.
    Si-Mohamed, Salim
    Noel, Peter B.
    Rummeny, Ernst J.
    Douek, Philippe
    Pfeiffer, Daniela
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [8] Optimization of K-Edge Imaging of Multiple Contrast Agents Using Photon-Counting Computed Tomography (PCCT)
    Richtsmeier, D.
    Dunning, C.
    Iniewski, K.
    Bazalova-Carter, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E276 - E276
  • [9] Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging
    Si-Mohamed, Salim
    Thivolet, Arnaud
    Bonnot, Pierre-Emmanuel
    Bar-Ness, Daniel
    Kepenekian, Vahan
    Cormode, David P.
    Douek, Philippe
    Rousset, Pascal
    INVESTIGATIVE RADIOLOGY, 2018, 53 (10) : 629 - 639
  • [10] K-edge Imaging with a Photon Counting CT System
    Matsumoto, Mariko
    Kaibuki, Futoshi
    Ogawa, Koichi
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,