No gadolinium K-edge detected on the first clinical photon-counting computed tomography scanner

被引:3
|
作者
Baubeta, Erik [1 ,2 ,5 ]
Laurin Gadsboll, Eva [1 ]
Will, Leon [1 ]
Holmquist, Fredrik [1 ,3 ]
Aurumskjold, Marie-Louise [4 ]
机构
[1] Skane Univ Hosp, Dept Imaging & Funct Med, Lund, Sweden
[2] Lund Univ, Dept Translat Med, Diagnost Radiol, Malmo, Sweden
[3] Lund Univ, Dept Clin Sci, Diagnost Radiol, Lund, Sweden
[4] Lund Univ, Dept Clin Sci Malmo, Med Radiat Phys, Dept Clin Sci, Lund, Sweden
[5] Skane Univ Hosp, Dept Imaging & Funct Med, S-22185 Lund, Sweden
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2024年 / 25卷 / 04期
关键词
computed tomography; EICT; energy integrated computed tomography; gadolinium contrast agent; iodine contrast agent; K-edge; material decomposition; PCCT; photon counting computed tomography; CONTRAST-MEDIA; CT;
D O I
10.1002/acm2.14324
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aimed to elucidate whether gadolinium contrast in clinically relevant doses can be used with photon-counting computed tomography (PCCT) as an alternative contrast agent in clinical applications. Material/methods: A CTDI phantom with 3D printed rods filled with different concentrations of gadolinium and iodine contrast was scanned in a PCCT and an energy-integrated computed tomography (EICT). Attenuation values at different monoenergetic steps were extracted for each contrast concentration. Results: For PCCT, gadolinium reached an attenuation >100 HU (103 HU) at 40 keV with a concentration 5 mmol/L whereas the same level was reached at 50 keV (118 HU) for 10 mmol/L and 90 keV (114 HU) for 25 mmol/L. For iodine, the same level of attenuation was reached at 100 keV (106 HU) with a concentration 8.75 mg I/mL. For EICT the lowest gadolinium contrast concentration needed to reach >100 HU (108 HU) was 10 mmol/L at 50 keV. For 25 mmol/L 100 HU was reached at 100 keV. For iodine contrast 108 HU was reached at 110 keV for 8.75 mg I/mL. Conclusion: No K-edge potential or difference in attenuation curves between iodine and gadolinium contrast is detected on the first clinical available PCCT. Clinically relevant attenuation levels were barely achieved in this setting with gadolinium concentrations approved for human use. The results of this study suggest that, given current scanning technology, gadolinium is not a clinically useful contrast agent for computed tomography because no K-edge was detected.
引用
收藏
页数:7
相关论文
共 50 条
  • [11] Liquid Embolic Agents in Spectral X-Ray Photon-Counting Computed Tomography using Tantalum K-Edge Imaging
    Isabelle Riederer
    Daniel Bar-Ness
    Melanie A. Kimm
    Salim Si-Mohamed
    Peter B. Noël
    Ernst J. Rummeny
    Philippe Douek
    Daniela Pfeiffer
    Scientific Reports, 9
  • [12] Evaluation of gold K-edge imaging using spectral computed tomography with a photon-counting detector: A Monte Carlo simulation study
    Kang, Sooncheol
    Eom, Jisoo
    Kim, Burnyoung
    Lee, Seungwan
    OPTIK, 2017, 140 : 253 - 260
  • [13] Liquid Embolic Agents in Spectral X-Ray Photon-Counting Computed Tomography using Tantalum K-Edge Imaging
    Riederer, Isabelle
    Bar-Ness, Daniel
    Kimm, Melanie A.
    Si-Mohamed, Salim
    Noel, Peter B.
    Rummeny, Ernst J.
    Douek, Philippe
    Pfeiffer, Daniela
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [14] Energy calibration of a photon-counting CT with K-edge absorption features
    Murata, Kazumi
    Ogawa, Koichi
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [15] Development of a scanner-specific simulation framework for photon-counting computed tomography
    Abadi, Ehsan
    Harrawood, Brian
    Rajagopal, Jayasai R.
    Sharma, Shobhit
    Kapadia, Anuj
    Segars, William Paul
    Stierstorfer, Karl
    Sedlmair, Martin
    Jones, Elizabeth
    Samei, Ehsan
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (05):
  • [16] Photon-counting computed tomography in radiology
    Algin, Oktay
    Tokgoz, Nazime
    Cademartiri, Filippo
    POLISH JOURNAL OF RADIOLOGY, 2024, 89 : e433 - e442
  • [17] Computed tomography with a full FOV photon-counting detector in a clinical setting, the first experience
    Ferda, Jiri
    Vendis, Tomas
    Flohr, Thomas
    Schmidt, Bernhard
    Henning, Andre
    Ulzheimer, Stefan
    Pecen, Ladislav
    Ferdova, Eva
    Baxa, Jan
    Mirka, Hynek
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 137
  • [18] Gadolinium K-edge angiography with a spectral photon counting CT in atherosclerotic rabbits
    Boccalini, Sara
    Dessouky, Riham
    Rodesch, Pierre-Antoine
    Lacombe, Hugo
    Yagil, Yoad
    Lahoud, Elias
    Erhard, Klaus
    Brendel, Bernhard
    Coulon, Philippe
    Langlois, Jean-Baptiste
    Chaput, Frederic
    Parola, Stephane
    Boussel, Loic
    Lerouge, Frederic
    Si-Mohamed, Salim
    Douek, Philippe C.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (10) : 490 - 499
  • [19] New Contrast Media for K-Edge Imaging With Photon-Counting Detector CT
    Jost, Gregor
    McDermott, Michael
    Gutjahr, Ralf
    Nowak, Tristan
    Schmidt, Bernhard
    Pietsch, Hubertus
    INVESTIGATIVE RADIOLOGY, 2023, 58 (07) : 515 - 522
  • [20] Improving material separation of high-flux whole-body photon-counting computed tomography by K-edge pre-filtration
    Polster, C.
    Gutjahr, R.
    Berner, M.
    Flohr, T.
    Hertel, M.
    Kappler, S.
    Stierstorfer, K.
    Dietrich, O.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132