No gadolinium K-edge detected on the first clinical photon-counting computed tomography scanner

被引:3
|
作者
Baubeta, Erik [1 ,2 ,5 ]
Laurin Gadsboll, Eva [1 ]
Will, Leon [1 ]
Holmquist, Fredrik [1 ,3 ]
Aurumskjold, Marie-Louise [4 ]
机构
[1] Skane Univ Hosp, Dept Imaging & Funct Med, Lund, Sweden
[2] Lund Univ, Dept Translat Med, Diagnost Radiol, Malmo, Sweden
[3] Lund Univ, Dept Clin Sci, Diagnost Radiol, Lund, Sweden
[4] Lund Univ, Dept Clin Sci Malmo, Med Radiat Phys, Dept Clin Sci, Lund, Sweden
[5] Skane Univ Hosp, Dept Imaging & Funct Med, S-22185 Lund, Sweden
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2024年 / 25卷 / 04期
关键词
computed tomography; EICT; energy integrated computed tomography; gadolinium contrast agent; iodine contrast agent; K-edge; material decomposition; PCCT; photon counting computed tomography; CONTRAST-MEDIA; CT;
D O I
10.1002/acm2.14324
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study aimed to elucidate whether gadolinium contrast in clinically relevant doses can be used with photon-counting computed tomography (PCCT) as an alternative contrast agent in clinical applications. Material/methods: A CTDI phantom with 3D printed rods filled with different concentrations of gadolinium and iodine contrast was scanned in a PCCT and an energy-integrated computed tomography (EICT). Attenuation values at different monoenergetic steps were extracted for each contrast concentration. Results: For PCCT, gadolinium reached an attenuation >100 HU (103 HU) at 40 keV with a concentration 5 mmol/L whereas the same level was reached at 50 keV (118 HU) for 10 mmol/L and 90 keV (114 HU) for 25 mmol/L. For iodine, the same level of attenuation was reached at 100 keV (106 HU) with a concentration 8.75 mg I/mL. For EICT the lowest gadolinium contrast concentration needed to reach >100 HU (108 HU) was 10 mmol/L at 50 keV. For 25 mmol/L 100 HU was reached at 100 keV. For iodine contrast 108 HU was reached at 110 keV for 8.75 mg I/mL. Conclusion: No K-edge potential or difference in attenuation curves between iodine and gadolinium contrast is detected on the first clinical available PCCT. Clinically relevant attenuation levels were barely achieved in this setting with gadolinium concentrations approved for human use. The results of this study suggest that, given current scanning technology, gadolinium is not a clinically useful contrast agent for computed tomography because no K-edge was detected.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
    Roessl, E.
    Proksa, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15): : 4679 - 4696
  • [42] K-edge Imaging with a Photon Counting CT System
    Matsumoto, Mariko
    Kaibuki, Futoshi
    Ogawa, Koichi
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [43] Comparison of quantitative k-edge empirical estimators using an energy-resolved photon-counting detector
    Zimmerman, Kevin C.
    Schmidt, Taly Gilat
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [44] Spectral Photon-counting CT: Initial Experience with Dual-Contrast Agent K-Edge Colonography
    Muenzel, Daniela
    Bar-Ness, Daniel
    Roessl, Ewald
    Blevis, Ira
    Bartels, Matthias
    Fingerle, Alexander A.
    Ruschke, Stefan
    Coulon, Philippe
    Daerr, Heiner
    Kopp, Felix K.
    Brendel, Bernhard
    Thran, Axel
    Rokni, Michal
    Herzen, Julia
    Boussel, Loic
    Pfeiffer, Franz
    Proksa, Roland
    Rummeny, Ernst J.
    Douek, Philippe
    Noel, Peter B.
    RADIOLOGY, 2017, 283 (03) : 722 - 727
  • [45] Photon-Counting Computed Tomography May Quantify Lever Fat
    Kumar, Pratik
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (01) : 100 - 100
  • [46] Model and reconstruction of a K-edge contrast agent distribution with an X-ray photon-counting detector
    Meng, Bo
    Cong, Wenxiang
    Xi, Yan
    De Man, Bruno
    Yang, Jian
    Wang, Ge
    OPTICS EXPRESS, 2017, 25 (08): : 9378 - 9392
  • [47] Photon-Counting Computed Tomography for Microstructural Imaging of Bone and Joints
    Quintiens, Jilmen
    van Lenthe, G. Harry
    CURRENT OSTEOPOROSIS REPORTS, 2024, 22 (04) : 387 - 395
  • [48] Microstructural Imaging of Bone by Photon-Counting Detector Computed Tomography
    Burghardt, Andrew
    Korajac, Aida
    Strassl, Andreas
    Sadoughi, Saghi
    Kazakia, Galateia
    Patsch, Janina
    JOURNAL OF BONE AND MINERAL RESEARCH, 2023, 38 : 342 - 343
  • [49] Photon-Counting Computed Tomography - Basic Principles, Potenzial Benefits, and Initial Clinical Experience
    Stein, Thomas
    Rau, Alexander
    Russe, Maximilian Frederik
    Arnold, Philipp
    Faby, Sebastian
    Ulzheimer, Stefan
    Weis, Meike
    Froelich, Matthias F.
    Overhoff, Daniel
    Horger, Marius
    Hagen, Florian
    Bongers, Malte
    Nikolaou, Konstantin
    Schoenberg, Stefan O.
    Bamberg, Fabian
    Weiss, Jakob
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, 195 (08): : 691 - 698
  • [50] Spectral Photon-Counting Computed Tomography for Classification of Liver Lesions
    Muenzel, D.
    Daer, H.
    Proksa, R.
    Fingerle, A.
    Kopp, F.
    Douek, P.
    Herzen, J.
    Pfeiffer, F.
    Rummeny, E.
    Noel, P. B.
    MEDICAL PHYSICS, 2017, 44 (06) : 3233 - 3233