Mechanical stability of angulated zirconia abutments supporting maxillary anterior single crowns on narrow-diameter implants

被引:0
|
作者
Ma, Ruiyang [1 ]
Yu, Ping [2 ]
Zhang, Yuqiang [1 ]
Xie, Chenyang [1 ]
Tan, Xin [1 ]
Sun, Jikui [1 ]
Yu, Haiyang [1 ]
机构
[1] Sichuan Univ, West China Hosp Stomatol, Natl Clin Res Ctr Oral Dis, State Key Lab Oral Dis, 14 Renmin South Rd,3rd Sect, Chengdu 610041, Sichuan, Peoples R China
[2] Chengdu Second Peoples Hosp, Dept Stomatol, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
Implant abutment connection; Angled zirconia abutment; Titanium base; Fracture strength; Bending moment; ALL-CERAMIC CROWNS; TITANIUM-ZIRCONIUM; FRACTURE-RESISTANCE; EXCESS CEMENT; IN-VITRO; DENTAL IMPLANTS; INTERNAL CONNECTION; CUSTOM ABUTMENTS; RESIDUAL CEMENT; BENDING MOMENTS;
D O I
10.1007/s00784-022-04715-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To investigate the fracture strength of angulated hybrid abutments supporting anterior single crowns on narrow-diameter implants (NDIs). Material and methods Zirconia abutment with angulations of labial inclination 0 degrees (TZ0Z), 15 degrees (TZ15Z), 30 degrees (TZ30Z) and palatal inclination 15 degrees (TZ - 15Z) was designed on 3.3-mm titanium-zirconium (Ti-Zr) NDIs. Titanium abutment connected with Ti-Zr implant (TZ0T) and 0 degrees zirconia abutment connected with pure titanium (Ti) implant (T0Z) were control groups. Thirty-six un-restored abutments and 36 abutments restored with highly translucent zirconia (HTZ) crowns were tested. Failure loads were compared among 6 groups, and bending moments were calculated for comparison between un-restored and restored abutments. Results Failure loads of un-restored abutments were affected by the abutment angle. Sixty-seven percent samples in TZ30Z and 83% samples in TZ - 15Z group fractured at the thinnest part of the zirconia abutment and exhibited lower failure load (p < .05). Failure loads of restored abutments were close to or exceeded the maximum bite force of anterior teeth, and no differences were found among six groups (p > .05). Except TZ15Z and TZ0T group, the bending moment increased with the crown construction, especially for TZ30Z and TZ - 15Z groups (p < .001). Conclusions The fracture strength of hybrid abutments restored with HTZ crown on Ti-Zr NDIs exceeded the bite forces of anterior teeth for all the groups and were not affected by the abutment angle.
引用
收藏
页码:221 / 233
页数:13
相关论文
共 50 条
  • [21] Are there differences between two-piece and one-piece zirconia abutments supporting single prosthetic restorations in the maxillary anterior region?
    Paolantoni, G.
    Marenzi, G.
    Blasi, A.
    Mignogna, J.
    Sammartino, G.
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2017, 10 (01) : 108 - 108
  • [22] Clinical challenges of biomechanical performance of narrow-diameter implants in maxillary posterior teeth in aging patients: A finite element analysis
    Prasitwuttisak, Saranyoo
    Chantarapanich, Nattapon
    Apinyauppatham, Komsan
    Poomparnich, Kopchai
    Inglam, Samroeng
    PLOS ONE, 2024, 19 (03): : 1 - 17
  • [23] Maxillary and mandibular overdentures retained by two unsplinted narrow-diameter titanium-zirconium implants - A clinical pilot study
    Kern, Jaana-Sophia
    Salin, Esra
    Elvers, Dirk
    Rittich, Anne
    Tuna, Taskin
    Hoelzle, Frank
    Wolfart, Stefan
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (09) : 1138 - 1150
  • [24] Single-piece zirconia versus single-piece titanium, narrow-diameter dental implants in the anterior maxilla: 5-year post-loading results of a randomized clinical trial
    Henao, Paula Andrea Ruiz
    Magrin, Gabriel Leonardo
    Caneiro-Queija, Leticia
    Benfatti, Cesar Augusto Magalhaes
    Leira, Yago
    Linares-Gonzalez, Antonio
    Blanco-Carrion, Juan
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (10) : 1310 - 1323
  • [25] Mechanical Fatigue Analysis of PEEK as Alternative to Zirconia for Definitive Hybrid Abutments Supporting All-Ceramic Crowns
    Barbosa-Junior, Sales Antonio
    Rocha Pereira, Gabriel Kalil
    Dapieve, Kiara Serafini
    Machado, Pablo Soares
    Valandro, Luiz Felipe
    Schuh, Christian
    Xediek Consani, Rafael Leonardo
    Bacchi, Atais
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (06) : 1209 - 1217
  • [26] Fracture Resistance of Straight and Angulated Zirconia Implant Abutments Supporting Anterior Three-Unit Lithium Disilicate Fixed Dental Prostheses
    Saker, Samah
    El-Shahat, Sameh
    Ghazy, Mohamed
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (06) : 1240 - 1246
  • [27] Long-Term Follow-Up of 2.5-mm Narrow-Diameter Implants Supporting a Fixed Prostheses
    Anitua, Eduardo
    Saracho, Juan
    Begona, Leire
    Alkhraisat, Mohammad Hamdan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (04) : 769 - 777
  • [28] Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up
    Alrabiah, Mohammed
    Al Deeb, Modhi
    Alsahhaf, Abdulaziz
    AlFawaz, Yasser F.
    Al-Aali, Khulud
    Vohra, Fahim
    Abduljabbar, Tariq
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2020, 50 (02): : 97 - 105
  • [29] Two Versus Three Narrow-Diameter Implants with Locator Attachments Supporting Mandibular Overdentures: A Two-Year Prospective Study
    El-Sheikh, Ali M.
    Shihabuddin, Omar F.
    Ghoraba, Sahar M. F.
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012
  • [30] Eleven-Year Follow-Up of a Prospective Study of Zirconia Implant Abutments Supporting Single All-Ceramic Crowns in Anterior and Premolar Regions
    Zembic, Anja
    Philipp, Alexander Otto Hermann
    Haemmerle, Christoph Hans Franz
    Wohlwend, Arnold
    Sailer, Irena
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E417 - E426