Mechanical Fatigue Analysis of PEEK as Alternative to Zirconia for Definitive Hybrid Abutments Supporting All-Ceramic Crowns

被引:16
|
作者
Barbosa-Junior, Sales Antonio [1 ]
Rocha Pereira, Gabriel Kalil [2 ]
Dapieve, Kiara Serafini [2 ]
Machado, Pablo Soares [2 ]
Valandro, Luiz Felipe [2 ]
Schuh, Christian
Xediek Consani, Rafael Leonardo [1 ]
Bacchi, Atais [3 ]
机构
[1] Campinas State Univ FOP UNICAMP, MSciD & PhD Postgrad Program Dent Clin, Prosthodont Area, Piracicaba Dent Sch, Piracicaba, SP, Brazil
[2] Fed Univ Santa Maria UFSM, MSciD & PhD Postgrad Program Dent, Santa Maria, RS, Brazil
[3] Merid Fac IMED, Postgrad Program Dent, Passo Fundo, RS, Brazil
关键词
dental implants; lithium disilicate; mechanical cycling; single crowns; yttria-stabilized tetragonal zirconia; zirconium oxide; LITHIUM-DISILICATE; FINITE-ELEMENT; FRACTURE-TOUGHNESS; BIOFILM FORMATION; BOND STRENGTH; TITANIUM; FAILURE; PERFORMANCE; SURFACE; RELIABILITY;
D O I
10.11607/jomi.8262
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to inspect the mechanical fatigue behavior of an implant-supported restorative system using polyether ether ketone (PEEK) and yttria partially stabilized zirconia polycrystals (YZ) as materials for customized definitive implant-supported hybrid abutments, supporting two types of all-ceramic restorations: translucent zirconia (TZ) and lithium disilicate (LD) monolithic crowns. Materials and Methods: Forty Morse taper implants were included in epoxy resin. Titanium intermediary abutments were placed, and the specimens were randomly allocated into four groups (n = 10) according to the customized hybrid abutment material (PEEK or YZ) and the monolithic crowns (TZ or LD) representing a maxillary central incisor crown. The specimens were subjected to a mechanical fatigue test (step-stress analysis) by means of an initial 200-N load for 5,000 cycles and subsequent increase of 50 N (step-size) at each 10,000 cycles, until failure occurred. The load at failure and number of cycles until failure were recorded; survival probabilities and specimen displacement were calculated for each step. The failure pattern was evaluated, and the Weibull modulus was obtained for each condition. Results: Fatigue of both types of crowns was not influenced by the abutment material (LD-PEEK = LD-YZ; TZ-PEEK = TZ-YZ). In the PEEK abutment, the values obtained in the LD and TZ crowns showed no statistical difference; however, in the YZ abutment, the TZ crown presented a load at failure value that was statistically higher than that for LD. Failure pattern analysis revealed a higher prevalence of crown fracture for LD groups, while screw/implant platform fractures were shown for TZ groups. Conclusion: YZ and PEEK hybrid abutments promoted similar fatigue levels regardless of the crown materials, TZ crowns promoted a higher fatigue level than LD ones when associated with YZ abutments, and LD crowns promoted a similar fatigue level to TZ ones when associated with PEEK custom abutments. Higher prevalence of crown fractures was shown for LD and screw/implant platform fractures for TZ groups.
引用
收藏
页码:1209 / 1217
页数:9
相关论文
共 50 条
  • [1] Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging
    Muehlemann, Sven
    Truninger, Thomas C.
    Stawarczyk, Bogna
    Haemmerle, Christoph H. F.
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (01) : 74 - 81
  • [2] Analysis of the Effectiveness of Zirconia Abutments Combined With Zirconia All-Ceramic Crowns in Implant Restorations in the Anterior Region
    Yang, Yanzhong
    Chen, Changhui
    Tian, Xiaohua
    Jin, Lan
    MINERVA SURGERY, 2022,
  • [3] Analysis of the Effectiveness of Zirconia Abutments Combined With Zirconia All-Ceramic Crowns in Implant Restorations in the Anterior Region
    Yang, Yanzhong
    Chen, Changhui
    Tian, Xiaohua
    Jin, Lan
    MINERVA SURGERY, 2024, 79 (01): : 105 - 107
  • [4] Fatigue and Stress Distribution Analyses of Ceramic-Reinforced PEEK Abutments Restored with Monolithic Zirconia Crowns as an Alternative to Conventional Esthetic Abutments
    Akan, Ender
    Velioglu, Emre
    Comlekoglu, Muharrem Erhan
    Comlekoglu, Mine Dundar
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (03) : 533 - 542
  • [5] Marginal Adaptation of All-Ceramic Crowns on Implant Abutments
    Att, Wael
    Hoischen, Tomas
    Gerds, Thomas
    Strub, Joerg Rudolf
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (04) : 218 - 225
  • [6] Zirconia implant abutments supporting single all-ceramic crowns in anterior and premolar regions: A six-year retrospective study
    Chen, Jo-Yu
    Pan, Yu-Hwa
    BIOMEDICAL JOURNAL, 2019, 42 (05) : 358 - 364
  • [7] Mechanical Stability of Zirconia Meso-abutments Bonded to Titanium Bases Restored with Different Monolithic All-Ceramic Crowns
    Pitta, Joao
    Hicklin, Stefan P.
    Fehmer, Vincent
    Boldt, Johannes
    Gierthmuehlen, Petra C.
    Sailer, Irena
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (05) : 1086 - 1092
  • [8] Mechanical behavior of posterior all-ceramic hybrid-abutment-crowns versus hybrid-abutments with separate crowns-A laboratory study
    Nouh, Ingy
    Kern, Matthias
    Sabet, Ahmed E.
    Aboelfadl, Ahmad K.
    Hamdy, Amina M.
    Chaar, Mohamed S.
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (01) : 90 - 98
  • [9] Fracture resistance of different implant abutments supporting all-ceramic single crowns after aging
    Stimmelmayr, M.
    Heiss, P.
    Erdelt, K.
    Schweiger, J.
    Beuer, F.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2017, 20 (01) : 53 - 64
  • [10] All-ceramic crowns on modified CeraOne abutments: A case report
    Probster, L
    QUINTESSENCE INTERNATIONAL, 1998, 29 (01): : 52 - 65