Mechanical Fatigue Analysis of PEEK as Alternative to Zirconia for Definitive Hybrid Abutments Supporting All-Ceramic Crowns

被引:16
|
作者
Barbosa-Junior, Sales Antonio [1 ]
Rocha Pereira, Gabriel Kalil [2 ]
Dapieve, Kiara Serafini [2 ]
Machado, Pablo Soares [2 ]
Valandro, Luiz Felipe [2 ]
Schuh, Christian
Xediek Consani, Rafael Leonardo [1 ]
Bacchi, Atais [3 ]
机构
[1] Campinas State Univ FOP UNICAMP, MSciD & PhD Postgrad Program Dent Clin, Prosthodont Area, Piracicaba Dent Sch, Piracicaba, SP, Brazil
[2] Fed Univ Santa Maria UFSM, MSciD & PhD Postgrad Program Dent, Santa Maria, RS, Brazil
[3] Merid Fac IMED, Postgrad Program Dent, Passo Fundo, RS, Brazil
关键词
dental implants; lithium disilicate; mechanical cycling; single crowns; yttria-stabilized tetragonal zirconia; zirconium oxide; LITHIUM-DISILICATE; FINITE-ELEMENT; FRACTURE-TOUGHNESS; BIOFILM FORMATION; BOND STRENGTH; TITANIUM; FAILURE; PERFORMANCE; SURFACE; RELIABILITY;
D O I
10.11607/jomi.8262
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to inspect the mechanical fatigue behavior of an implant-supported restorative system using polyether ether ketone (PEEK) and yttria partially stabilized zirconia polycrystals (YZ) as materials for customized definitive implant-supported hybrid abutments, supporting two types of all-ceramic restorations: translucent zirconia (TZ) and lithium disilicate (LD) monolithic crowns. Materials and Methods: Forty Morse taper implants were included in epoxy resin. Titanium intermediary abutments were placed, and the specimens were randomly allocated into four groups (n = 10) according to the customized hybrid abutment material (PEEK or YZ) and the monolithic crowns (TZ or LD) representing a maxillary central incisor crown. The specimens were subjected to a mechanical fatigue test (step-stress analysis) by means of an initial 200-N load for 5,000 cycles and subsequent increase of 50 N (step-size) at each 10,000 cycles, until failure occurred. The load at failure and number of cycles until failure were recorded; survival probabilities and specimen displacement were calculated for each step. The failure pattern was evaluated, and the Weibull modulus was obtained for each condition. Results: Fatigue of both types of crowns was not influenced by the abutment material (LD-PEEK = LD-YZ; TZ-PEEK = TZ-YZ). In the PEEK abutment, the values obtained in the LD and TZ crowns showed no statistical difference; however, in the YZ abutment, the TZ crown presented a load at failure value that was statistically higher than that for LD. Failure pattern analysis revealed a higher prevalence of crown fracture for LD groups, while screw/implant platform fractures were shown for TZ groups. Conclusion: YZ and PEEK hybrid abutments promoted similar fatigue levels regardless of the crown materials, TZ crowns promoted a higher fatigue level than LD ones when associated with YZ abutments, and LD crowns promoted a similar fatigue level to TZ ones when associated with PEEK custom abutments. Higher prevalence of crown fractures was shown for LD and screw/implant platform fractures for TZ groups.
引用
收藏
页码:1209 / 1217
页数:9
相关论文
共 50 条
  • [31] Fracture resistance of zirconia-based all-ceramic crowns after bur adjustment
    Rues, Stefan
    Schwindling, Franz S.
    Meyer, Andre
    Rammelsberg, Peter
    Schmitter, Marc
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2017, 125 (04) : 310 - 313
  • [32] Effect of substrate and cement on the final color of zirconia-based all-ceramic crowns
    Sonza, Queli N.
    Della Bona, Alvaro
    Pecho, Oscar E.
    Borba, Marcia
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2021, 33 (06) : 891 - 898
  • [33] Fracture Loads of All-Ceramic Crowns under Wet and Dry Fatigue Conditions
    Borges, Gilberto A.
    Caldas, Danilo
    Taskonak, Burak
    Yan, Jiahau
    Sobrinho, Lourenco Correr
    de Oliveira, Wildomar Jose
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (08): : 649 - 655
  • [34] Factorial analysis of variables influencing stress in all-ceramic crowns
    Rekow, ED
    Harsono, M
    Janal, M
    Thompson, VP
    Zhang, GM
    DENTAL MATERIALS, 2006, 22 (02) : 125 - 132
  • [35] Chipping behaviour of all-ceramic crowns with zirconia framework and CAD/CAM manufactured veneer
    Schmitter, M.
    Mueller, D.
    Rues, S.
    JOURNAL OF DENTISTRY, 2012, 40 (02) : 154 - 162
  • [37] Two-piece zirconia implants supporting all-ceramic crowns: Six-year results of a prospective cohort study
    Cionca, Norbert
    Hashim, Dena
    Mombelli, Andrea
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (06) : 695 - 701
  • [38] Influence of Thermomechanical Fatigue Loading on the Fracture Resistance of All-ceramic Posterior Crowns
    Senyilmaz, Dilek Pinar
    Canay, Senay
    Heydecke, Guido
    Strub, Joerg Rudolf
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2010, 18 (02): : 50 - 54
  • [39] BIOMECHANICAL ANALYSIS OF INDIVIDUAL ALL-CERAMIC ABUTMENTS USED IN DENTAL IMPLANTOLOGY
    Ziebowicz, B.
    Ziebowicz, A.
    Baczkowski, B.
    Kajzer, W.
    Kajzer, A.
    ARCHIVES OF METALLURGY AND MATERIALS, 2016, 61 (03) : 1011 - 1016
  • [40] Esthetic and Clinical Performance of Implant-Supported All-Ceramic Crowns Made with Prefabricated or CAD/CAM Zirconia Abutments: A Randomized, Multicenter Clinical Trial
    Wittneben, J. G.
    Gavric, J.
    Belser, U. C.
    Bornstein, M. M.
    Joda, T.
    Chappuis, V.
    Sailer, I.
    Bragger, U.