Mechanical Fatigue Analysis of PEEK as Alternative to Zirconia for Definitive Hybrid Abutments Supporting All-Ceramic Crowns

被引:16
|
作者
Barbosa-Junior, Sales Antonio [1 ]
Rocha Pereira, Gabriel Kalil [2 ]
Dapieve, Kiara Serafini [2 ]
Machado, Pablo Soares [2 ]
Valandro, Luiz Felipe [2 ]
Schuh, Christian
Xediek Consani, Rafael Leonardo [1 ]
Bacchi, Atais [3 ]
机构
[1] Campinas State Univ FOP UNICAMP, MSciD & PhD Postgrad Program Dent Clin, Prosthodont Area, Piracicaba Dent Sch, Piracicaba, SP, Brazil
[2] Fed Univ Santa Maria UFSM, MSciD & PhD Postgrad Program Dent, Santa Maria, RS, Brazil
[3] Merid Fac IMED, Postgrad Program Dent, Passo Fundo, RS, Brazil
关键词
dental implants; lithium disilicate; mechanical cycling; single crowns; yttria-stabilized tetragonal zirconia; zirconium oxide; LITHIUM-DISILICATE; FINITE-ELEMENT; FRACTURE-TOUGHNESS; BIOFILM FORMATION; BOND STRENGTH; TITANIUM; FAILURE; PERFORMANCE; SURFACE; RELIABILITY;
D O I
10.11607/jomi.8262
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to inspect the mechanical fatigue behavior of an implant-supported restorative system using polyether ether ketone (PEEK) and yttria partially stabilized zirconia polycrystals (YZ) as materials for customized definitive implant-supported hybrid abutments, supporting two types of all-ceramic restorations: translucent zirconia (TZ) and lithium disilicate (LD) monolithic crowns. Materials and Methods: Forty Morse taper implants were included in epoxy resin. Titanium intermediary abutments were placed, and the specimens were randomly allocated into four groups (n = 10) according to the customized hybrid abutment material (PEEK or YZ) and the monolithic crowns (TZ or LD) representing a maxillary central incisor crown. The specimens were subjected to a mechanical fatigue test (step-stress analysis) by means of an initial 200-N load for 5,000 cycles and subsequent increase of 50 N (step-size) at each 10,000 cycles, until failure occurred. The load at failure and number of cycles until failure were recorded; survival probabilities and specimen displacement were calculated for each step. The failure pattern was evaluated, and the Weibull modulus was obtained for each condition. Results: Fatigue of both types of crowns was not influenced by the abutment material (LD-PEEK = LD-YZ; TZ-PEEK = TZ-YZ). In the PEEK abutment, the values obtained in the LD and TZ crowns showed no statistical difference; however, in the YZ abutment, the TZ crown presented a load at failure value that was statistically higher than that for LD. Failure pattern analysis revealed a higher prevalence of crown fracture for LD groups, while screw/implant platform fractures were shown for TZ groups. Conclusion: YZ and PEEK hybrid abutments promoted similar fatigue levels regardless of the crown materials, TZ crowns promoted a higher fatigue level than LD ones when associated with YZ abutments, and LD crowns promoted a similar fatigue level to TZ ones when associated with PEEK custom abutments. Higher prevalence of crown fractures was shown for LD and screw/implant platform fractures for TZ groups.
引用
收藏
页码:1209 / 1217
页数:9
相关论文
共 50 条
  • [41] Fracture Load of Implant-Supported Zirconia All-Ceramic Crowns Luted with Various Cements
    Lim, Hyun-Pil
    Yoo, Jeong-Min
    Park, Sang-Won
    Yang, Hong-So
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2010, 23 (04) : 361 - 363
  • [42] Influence of Different Zirconia Coping Designs on the Fracture Resistance of All-Ceramic Crowns: An In Vitro Study
    Shetty, Sanath K.
    Fayaz, Tharammal
    Zahid, Mohammed
    Suhaim, Karkala S.
    Ragher, Mallikarjun
    Hasan, Mohammed S.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2020, 12 : 517 - 522
  • [43] Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crowns
    Suputtamongkol, Kallaya
    Tulapornchai, Chantana
    Mamani, Jatuphol
    Kamchatphai, Wannaporn
    Thongpun, Noparat
    JOURNAL OF ADVANCED PROSTHODONTICS, 2013, 5 (03): : 319 - 325
  • [44] Fatigue testing of two porcelain-zirconia all-ceramic crown systems
    Coelho, P. G.
    Silva, N. R.
    Bonfante, E. A.
    Guess, P. C.
    Rekow, E. D.
    Thompson, V. P.
    DENTAL MATERIALS, 2009, 25 (09) : 1122 - 1127
  • [45] THE FAILURE PROBABILITY OF ALL-CERAMIC CROWNS - A FINITE-ELEMENT-ANALYSIS
    WEIGL, P
    GESE, H
    MAHLER, A
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 523 - 523
  • [46] In Vitro Effect of Anodization of Titanium Abutments on Color Parameters and Color Difference of Lithium Disilicate All-Ceramic Crowns
    Khorshidi, Sotude
    Zarbakhsh, Arash
    Lawaf, Shirin
    Golalipour, Shaghayegh
    Sayyari, Maryam
    Nahavandi, Alireza Mahmoudi
    CLINICAL AND EXPERIMENTAL DENTAL RESEARCH, 2024, 10 (05):
  • [47] Mechanical stability of all-ceramic abutments retained with three different screw materials in two-piece zirconia implants—an in vitro study
    Michael Stimmelmayr
    Anna Lang
    Florian Beuer
    Sonia Mansour
    Kurt Erdelt
    Gerald Krennmair
    Jan-Frederik Güth
    Clinical Oral Investigations, 2020, 24 : 1801 - 1806
  • [48] The influence of zirconia coping designs on maximum principal stress distribution in all-ceramic premolar crowns: A finite element analysis
    Diker, Burcu
    Erkut, Selim
    AMERICAN JOURNAL OF DENTISTRY, 2019, 32 (05): : 255 - 259
  • [49] Comparison of the Load-bearing Capacities of Monolithic PEEK, Zirconia and Hybrid Ceramic Molar Crowns
    Tartuk, Bulent Kadir
    Ayna, Emrah
    Basaran, Emine Goncu
    MEANDROS MEDICAL AND DENTAL JOURNAL, 2019, 20 (01): : 45 - 50
  • [50] Thermal/mechanical simulation and laboratory fatigue testing of an alternative yttria tetragonal zirconia polycrystal core-veneer all-ceramic layered crown design
    Bonfante, Estevam A.
    Rafferty, Brian
    Zavanelli, Ricardo A.
    Silva, Nelson R. F. A.
    Rekow, Elizabeth D.
    Thompson, Van P.
    Coelho, Paulo G.
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2010, 118 (02) : 202 - 209