Mechanical stability of angulated zirconia abutments supporting maxillary anterior single crowns on narrow-diameter implants

被引:0
|
作者
Ma, Ruiyang [1 ]
Yu, Ping [2 ]
Zhang, Yuqiang [1 ]
Xie, Chenyang [1 ]
Tan, Xin [1 ]
Sun, Jikui [1 ]
Yu, Haiyang [1 ]
机构
[1] Sichuan Univ, West China Hosp Stomatol, Natl Clin Res Ctr Oral Dis, State Key Lab Oral Dis, 14 Renmin South Rd,3rd Sect, Chengdu 610041, Sichuan, Peoples R China
[2] Chengdu Second Peoples Hosp, Dept Stomatol, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
Implant abutment connection; Angled zirconia abutment; Titanium base; Fracture strength; Bending moment; ALL-CERAMIC CROWNS; TITANIUM-ZIRCONIUM; FRACTURE-RESISTANCE; EXCESS CEMENT; IN-VITRO; DENTAL IMPLANTS; INTERNAL CONNECTION; CUSTOM ABUTMENTS; RESIDUAL CEMENT; BENDING MOMENTS;
D O I
10.1007/s00784-022-04715-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To investigate the fracture strength of angulated hybrid abutments supporting anterior single crowns on narrow-diameter implants (NDIs). Material and methods Zirconia abutment with angulations of labial inclination 0 degrees (TZ0Z), 15 degrees (TZ15Z), 30 degrees (TZ30Z) and palatal inclination 15 degrees (TZ - 15Z) was designed on 3.3-mm titanium-zirconium (Ti-Zr) NDIs. Titanium abutment connected with Ti-Zr implant (TZ0T) and 0 degrees zirconia abutment connected with pure titanium (Ti) implant (T0Z) were control groups. Thirty-six un-restored abutments and 36 abutments restored with highly translucent zirconia (HTZ) crowns were tested. Failure loads were compared among 6 groups, and bending moments were calculated for comparison between un-restored and restored abutments. Results Failure loads of un-restored abutments were affected by the abutment angle. Sixty-seven percent samples in TZ30Z and 83% samples in TZ - 15Z group fractured at the thinnest part of the zirconia abutment and exhibited lower failure load (p < .05). Failure loads of restored abutments were close to or exceeded the maximum bite force of anterior teeth, and no differences were found among six groups (p > .05). Except TZ15Z and TZ0T group, the bending moment increased with the crown construction, especially for TZ30Z and TZ - 15Z groups (p < .001). Conclusions The fracture strength of hybrid abutments restored with HTZ crown on Ti-Zr NDIs exceeded the bite forces of anterior teeth for all the groups and were not affected by the abutment angle.
引用
收藏
页码:221 / 233
页数:13
相关论文
共 50 条
  • [31] Mechanical Stability of Zirconia Implant Abutments Supporting Cantilevered Fixed Dental Prostheses After Fatigue Loading
    Karasan, Duygu
    Att, Wael
    Sailer, Irena
    Canay, Senay
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2021, 34 (05) : 615 - 625
  • [32] Monolithic Zirconia Single Crowns Supported by Narrow- or Standard-Diameter Titanium-Zirconia Implants in Posterior Sites: 1-Year Results of a Randomized Controlled Trial
    Alsabeeha, Nabeel H. M.
    Amir-Rad, Fatemeh
    Ma, Sunyoung
    Shah, Maanas
    Hannawi, Haifa
    Tawse-Smith, Andrew
    Duncan, Warwick J.
    Baqain, Zaid H.
    Atieh, Momen A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2025, 40 (01) : 90 - 98
  • [33] Mechanical Stability of Restorations Supported by Titanium Base, Zirconia, and Polyetherketoneketone Abutments on One- and Two-Piece Zirconia Implants
    Cantarella, Josef
    Pitta, Joao
    Mojon, Philippe
    Hicklin, Stefan P.
    Fehmer, Vincent
    Sailer, Irena
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2021, 36 (02) : 313 - 321
  • [34] Primary stability of narrow-diameter dental implants with a multiple condensing thread design placed in bone with and without osteotomes: An in vitro study
    Romanos, Georgios E.
    Lau, Jessica
    Delgado-Ruiz, Rafael
    Javed, Fawad
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (03) : 409 - 414
  • [35] Same-Day Digital Dentistry Restorative Workflow for Single Immediate Provisionalization of Narrow-Diameter Implants: An Exploratory Prospective Study
    Deeb, Janina Golob
    Reddy, Nitya G. G.
    Hopfensperger, Liam J. J.
    Harris, April L. L.
    Bencharit, Sompop
    PROSTHESIS, 2023, 5 (01): : 197 - 207
  • [36] Four-unit fixed dental prostheses replacing the maxillary incisors supported by two narrow-diameter implants - a five-year case series
    Moraguez, Osvaldo
    Vailati, Francesca
    Grutter, Linda
    Sailer, Irena
    Belser, Urs C.
    CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (07) : 887 - 892
  • [37] Fracture strength of zirconia implant abutments on narrow diameter implants with internal and external implant abutment connections: A study on the titanium resin base concept
    Sailer, Irena
    Asgeirsson, Asgeir G.
    Thoma, Daniel S.
    Fehmer, Vincent
    Aspelund, Thor
    Ozcan, Mutlu
    Pjetursson, Bjarni E.
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (04) : 411 - 423
  • [38] Mechanical Stability of Zirconia Meso-abutments Bonded to Titanium Bases Restored with Different Monolithic All-Ceramic Crowns
    Pitta, Joao
    Hicklin, Stefan P.
    Fehmer, Vincent
    Boldt, Johannes
    Gierthmuehlen, Petra C.
    Sailer, Irena
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (05) : 1086 - 1092
  • [39] One-piece internal zirconia abutments for single-tooth restorations on narrow and regular diameter implants: A 5-year prospective follow-up study
    Nilsson, Andree
    Johansson, Lars-Ake
    Lindh, Christina
    Ekfeldt, Anders
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (05) : 916 - 925
  • [40] Randomized Controlled Multicenter Clinical Study Evaluating Crestal Bone Level Change of Narrow-Diameter Versus Standard-Diameter Ti-Zr Implants for Single Tooth Replacement in Anterior and Premolar Region
    Ghazal, Saba Sameeh
    Huynh-Ba, Guy
    Aghaloo, Tara
    Dibart, Serge
    Froum, Stuart
    O'Neal, Robert
    Cochran, David
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2019, 34 (03) : 708 - 718