Mechanical stability of angulated zirconia abutments supporting maxillary anterior single crowns on narrow-diameter implants

被引:0
|
作者
Ma, Ruiyang [1 ]
Yu, Ping [2 ]
Zhang, Yuqiang [1 ]
Xie, Chenyang [1 ]
Tan, Xin [1 ]
Sun, Jikui [1 ]
Yu, Haiyang [1 ]
机构
[1] Sichuan Univ, West China Hosp Stomatol, Natl Clin Res Ctr Oral Dis, State Key Lab Oral Dis, 14 Renmin South Rd,3rd Sect, Chengdu 610041, Sichuan, Peoples R China
[2] Chengdu Second Peoples Hosp, Dept Stomatol, Chengdu, Peoples R China
基金
中国国家自然科学基金;
关键词
Implant abutment connection; Angled zirconia abutment; Titanium base; Fracture strength; Bending moment; ALL-CERAMIC CROWNS; TITANIUM-ZIRCONIUM; FRACTURE-RESISTANCE; EXCESS CEMENT; IN-VITRO; DENTAL IMPLANTS; INTERNAL CONNECTION; CUSTOM ABUTMENTS; RESIDUAL CEMENT; BENDING MOMENTS;
D O I
10.1007/s00784-022-04715-3
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To investigate the fracture strength of angulated hybrid abutments supporting anterior single crowns on narrow-diameter implants (NDIs). Material and methods Zirconia abutment with angulations of labial inclination 0 degrees (TZ0Z), 15 degrees (TZ15Z), 30 degrees (TZ30Z) and palatal inclination 15 degrees (TZ - 15Z) was designed on 3.3-mm titanium-zirconium (Ti-Zr) NDIs. Titanium abutment connected with Ti-Zr implant (TZ0T) and 0 degrees zirconia abutment connected with pure titanium (Ti) implant (T0Z) were control groups. Thirty-six un-restored abutments and 36 abutments restored with highly translucent zirconia (HTZ) crowns were tested. Failure loads were compared among 6 groups, and bending moments were calculated for comparison between un-restored and restored abutments. Results Failure loads of un-restored abutments were affected by the abutment angle. Sixty-seven percent samples in TZ30Z and 83% samples in TZ - 15Z group fractured at the thinnest part of the zirconia abutment and exhibited lower failure load (p < .05). Failure loads of restored abutments were close to or exceeded the maximum bite force of anterior teeth, and no differences were found among six groups (p > .05). Except TZ15Z and TZ0T group, the bending moment increased with the crown construction, especially for TZ30Z and TZ - 15Z groups (p < .001). Conclusions The fracture strength of hybrid abutments restored with HTZ crown on Ti-Zr NDIs exceeded the bite forces of anterior teeth for all the groups and were not affected by the abutment angle.
引用
收藏
页码:221 / 233
页数:13
相关论文
共 50 条
  • [41] Clinical, radiographic, and aesthetic outcomes at two narrow-diameter implants to replace congenital missing maxillary lateral incisors: A 3-year prospective, clinical study
    Roccuzzo, Andrea
    Imber, Jean-Claude
    Lempert, Jakob
    Jensen, Simon Storgard
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (04) : 777 - 786
  • [42] Clinical analysis of the tooth-implant papilla for two narrow-diameter titanium-zirconium implants in the anterior area: prospective controlled clinical study
    Paola Herrera-Pérez
    Ana María García-De-La-Fuente
    Eztizen Andia-Larrea
    Xabier Marichalar-Mendia
    José Manuel Aguirre-Urizar
    Luis Antonio Aguirre-Zorzano
    BMC Oral Health, 24
  • [43] Clinical, Esthetic, and Radiographic Evaluation of Small-Diameter (3.0-mm) Implants Supporting Single Crowns in the Anterior Region: A 3-Year Prospective Study
    Pieri, Francesco
    Siroli, Lucia
    Forlivesi, Caterina
    Corinaldesi, Giuseppe
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2014, 34 (06) : 825 - 832
  • [44] Clinical analysis of the tooth-implant papilla for two narrow-diameter titanium-zirconium implants in the anterior area: prospective controlled clinical study
    Herrera-Perez, Paola
    Garcia-De-La-Fuente, Ana Maria
    Andia-Larrea, Eztizen
    Marichalar-Mendia, Xabier
    Aguirre-Urizar, Jose Manuel
    Aguirre-Zorzano, Luis Antonio
    BMC ORAL HEALTH, 2024, 24 (01)
  • [45] Clinical outcomes of titanium-zirconium alloy narrow-diameter implants for single-crown restorations: a systematic review and meta-analysis
    Cao, Rongkai
    Chen, Beibei
    Xu, Hui
    Fan, Zhen
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2023, 61 (06): : 403 - 410
  • [46] Effects of cyclic loading on loss of abutment screw torque of angled screw channel single implant crowns on narrow diameter implants
    Bhumpattarachai, Sasiya
    Kan, Joseph Y. K.
    Goodacre, Charles J.
    Swamidass, Rajesh S.
    Al-Ardah, Aladdin
    Rungcharassaeng, Kitichai
    Lozada, Jaime
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05): : 741e1 - 741e9
  • [47] Findings of a Four-Year Randomized Controlled Clinical Trial Comparing Two-Piece and One-Piece Zirconia Abutments Supporting Single Prosthetic Restorations in Maxillary Anterior Region
    Paolantoni, Guerino
    Marenzi, Gaetano
    Blasi, Andrea
    Mignogna, Jolanda
    Sammartino, Gilberto
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [48] A 3-year prospective clinical and radiologic analysis of early loaded maxillary dental implants supporting single-tooth crowns
    Turkyilmaz, Ilser
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2006, 19 (04) : 389 - 390
  • [49] Five-year results of a randomized controlled clinical trial comparing zirconia and titanium abutments supporting single-implant crowns in canine and posterior regions
    Zembic, Anja
    Boesch, Adrian
    Jung, Ronald E.
    Haemmerle, Christoph H. F.
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (04) : 384 - 390
  • [50] Mechanical stability of all-ceramic abutments retained with three different screw materials in two-piece zirconia implants—an in vitro study
    Michael Stimmelmayr
    Anna Lang
    Florian Beuer
    Sonia Mansour
    Kurt Erdelt
    Gerald Krennmair
    Jan-Frederik Güth
    Clinical Oral Investigations, 2020, 24 : 1801 - 1806