Comparison of the accuracy between full-arch digital scans and scannable impression materials: an in vitro study

被引:3
|
作者
Grande, Francesco [1 ,2 ,3 ]
Celeghin, Giordano [1 ]
Gallinaro, Federica [1 ]
Mobilio, Nicola [1 ]
Catapano, Santo [1 ]
机构
[1] Univ Ferrara, Dept Prosthodont, Ferrara, Italy
[2] Polytech Univ Turin, Dept Mech & Aerosp Engn, Turin, Italy
[3] Univ Ferrara, Dept Prosthodont, Via Luigi Borsari 46, I-44121 Ferrara, Italy
关键词
Dental impression materials; Dental arch; Dimensional measurement accuracy; CONVENTIONAL IMPRESSIONS; DENTAL IMPRESSIONS; MARGINAL FIT; RESTORATIONS; PRECISION; DIGITIZATION; TRUENESS; PATIENT;
D O I
10.23736/S2724-6329.23.04766-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BACKGROUND: In some clinical cases, full-arch impression could be difficult to take correctly with the digital way. Patients with high flow salivary rate or with difficulties in mouth opening can still benefit from a conventional impression with elastomer materials that can be directly or indirectly digitized. The aim of this study was to compare the accuracy and precision of two different intraoral scanners (IOSs) and an impression material with scannable properties, by means of three-dimensional analysis of a complete dental arch. METHODS: An anatomical model of complete upper arch, modified with a Scan body placed in the retroincisive area, was used. It was firstly scanned by a desktop scanner to create a digital reference model. Then, 3 groups were created, each constituted by 5 samples. In the first group, 5 impressions were taken from the same master model with the scan-nable PVS material (Hydrorise Implant), 5 scans were taken using Trios4 (3Shape) and other 5 scans with iTero Element 5D (iTero). STL files obtained from IOSs, and scanned impressions were three-dimensionally superimposed on the STL file of the reference model using the Scan body geometry. RESULTS: The ANOVA Test (P<0.005) did not show any statistically significant difference between the accuracy and precision values of the groups. Each group shows clinically acceptable deviations from the reference model. CONCLUSIONS: Scannable polyvinylsiloxane impression materials are equally accurate and precise as the two IOSs tested in full-arch dentate impressions.
引用
收藏
页码:168 / 175
页数:8
相关论文
共 50 条
  • [41] Solid index versus intraoral scanners in the full-arch implant impression: in vitro trueness evaluation
    Mangano, Francesco Guido
    Bonacina, Matteo
    Mandelli, Federico
    Marchiori, Fabio
    BMC RESEARCH NOTES, 2020, 13 (01)
  • [42] Conventional and digital complete arch implant impression techniques: An in vitro study comparing accuracy
    Gomez-Polo, Miguel
    Sallorenzo, Alessandro
    Cascos, Rocio
    Ballesteros, Juan
    Barmak, Abdul B.
    Revilla-Leon, Marta
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (04): : 809 - 818
  • [43] Solid index versus intraoral scanners in the full-arch implant impression: in vitro trueness evaluation
    Francesco Guido Mangano
    Matteo Bonacina
    Federico Mandelli
    Fabio Marchiori
    BMC Research Notes, 13
  • [44] The accuracy of conventional versus digital (intraoral scanner or photogrammetry) impression techniques in full-arch implant-supported prostheses: a systematic review
    Joensahakij, Nitchakul
    Serichetaphongse, Pravej
    Chengprapakorn, Wareeratn
    EVIDENCE-BASED DENTISTRY, 2024, 25 (04) : 216 - 217
  • [45] Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions
    Akkal, Ozcan
    Korkmaz, Ismail Hakki
    Bayindir, Funda
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (04): : 179 - 188
  • [46] Sources of error in maximum intercuspation from complete dentate full-arch intraoral scans in vitro
    Osnes, Cecilie
    Wu, Jianhua
    Ferrari, Marco
    Joda, Tim
    Keeling, Andrew
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2021, 24 (03) : 283 - 291
  • [47] Do digital impressions have a greater accuracy for full-arch implant-supported reconstructions compared to conventional impressions? An in vitro study
    Shaikh, Mohsin
    Lakha, Tabrez
    Kheur, Supriya
    Qamri, Batul
    Kheur, Mohit
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (04) : 398 - 404
  • [48] The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid-based in vitro study
    Schlenz, Maximiliane Amelie
    Klaus, Katharina
    Schmidt, Alexander
    Wostmann, Bernd
    Mersmann, Marco
    Ruf, Sabine
    Bock, Niko Christian
    CLINICAL ORAL INVESTIGATIONS, 2023, 27 (01) : 273 - 283
  • [49] Linear Accuracy of Full-Arch Digital Models Using Four Different Scanning Methods: An In Vitro Study Using a Coordinate Measuring Machine
    Kim, Young Hyun
    Han, Sang-Sun
    Choi, Yoon Joo
    Woo, Chang-Woo
    APPLIED SCIENCES-BASEL, 2020, 10 (08):
  • [50] Full-arch intraoral scanning: comparison of two different strategies and their accuracy outcomes
    Mandelli, F.
    Gherlone, E.
    Keeling, A.
    Gastaldi, G.
    Ferrari, M.
    JOURNAL OF OSSEOINTEGRATION, 2018, 10 (03) : 65 - 74