Comparison of the accuracy between full-arch digital scans and scannable impression materials: an in vitro study

被引:3
|
作者
Grande, Francesco [1 ,2 ,3 ]
Celeghin, Giordano [1 ]
Gallinaro, Federica [1 ]
Mobilio, Nicola [1 ]
Catapano, Santo [1 ]
机构
[1] Univ Ferrara, Dept Prosthodont, Ferrara, Italy
[2] Polytech Univ Turin, Dept Mech & Aerosp Engn, Turin, Italy
[3] Univ Ferrara, Dept Prosthodont, Via Luigi Borsari 46, I-44121 Ferrara, Italy
关键词
Dental impression materials; Dental arch; Dimensional measurement accuracy; CONVENTIONAL IMPRESSIONS; DENTAL IMPRESSIONS; MARGINAL FIT; RESTORATIONS; PRECISION; DIGITIZATION; TRUENESS; PATIENT;
D O I
10.23736/S2724-6329.23.04766-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BACKGROUND: In some clinical cases, full-arch impression could be difficult to take correctly with the digital way. Patients with high flow salivary rate or with difficulties in mouth opening can still benefit from a conventional impression with elastomer materials that can be directly or indirectly digitized. The aim of this study was to compare the accuracy and precision of two different intraoral scanners (IOSs) and an impression material with scannable properties, by means of three-dimensional analysis of a complete dental arch. METHODS: An anatomical model of complete upper arch, modified with a Scan body placed in the retroincisive area, was used. It was firstly scanned by a desktop scanner to create a digital reference model. Then, 3 groups were created, each constituted by 5 samples. In the first group, 5 impressions were taken from the same master model with the scan-nable PVS material (Hydrorise Implant), 5 scans were taken using Trios4 (3Shape) and other 5 scans with iTero Element 5D (iTero). STL files obtained from IOSs, and scanned impressions were three-dimensionally superimposed on the STL file of the reference model using the Scan body geometry. RESULTS: The ANOVA Test (P<0.005) did not show any statistically significant difference between the accuracy and precision values of the groups. Each group shows clinically acceptable deviations from the reference model. CONCLUSIONS: Scannable polyvinylsiloxane impression materials are equally accurate and precise as the two IOSs tested in full-arch dentate impressions.
引用
收藏
页码:168 / 175
页数:8
相关论文
共 50 条
  • [31] Trueness of full-arch dental models obtained by digital and conventional impression techniques: an in vivo study
    Onbasi, Yonca
    Abu-Hossin, Sabrin
    Paulig, Maria
    Berger, Lara
    Wichmann, Manfred
    Matta, Ragai-Edward
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [32] In-vitro evaluation of the accuracy of conventional and digital methods of obtaining full-arch dental impressions
    Ender, Andreas
    Mehl, Albert
    QUINTESSENCE INTERNATIONAL, 2015, 46 (01): : 9 - 17
  • [33] Accuracy of Different Elastomeric Impression Materials Using Dual Arch Impression Trays: An In Vitro Study
    Duseja, Sareen
    Shah, Dipti
    Vaishnav, Kalpesh
    Duseja, Shilpa
    Kumar, Santosh
    Desai, Khushboo
    ADVANCES IN HUMAN BIOLOGY, 2014, 4 (02) : 3 - 8
  • [34] An in-vitro study comparing the accuracy of full-arch casts digitized with desktop scanners
    Nowak, Roxana
    Wesemann, Christian
    Robben, Jan
    Muallah, Jonas
    Bumann, Axel
    QUINTESSENCE INTERNATIONAL, 2017, 48 (08): : 667 - 676
  • [35] Digital Impression Taking for Maxillary Full-Arch Restoration With Immediate Loading: A Case Report
    Rico, Jesus Pelaez
    Brinkmann, Jorge Cortes-Breton
    Martin, Maria Carrion
    Gonzalez, Mabel Albanchez
    Arribas, Celia Tobar
    Alonso, Veronica Rodriguez
    Suarez, Carlos Lopez
    Garcia, Maria Jesus Suarez
    JOURNAL OF ORAL IMPLANTOLOGY, 2022, 48 (02) : 125 - 132
  • [36] In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants
    Leonardo Ciocca
    Roberto Meneghello
    Carlo Monaco
    Gianpaolo Savio
    Lorenzo Scheda
    Maria Rosaria Gatto
    Paolo Baldissara
    International Journal of Computer Assisted Radiology and Surgery, 2018, 13 : 1097 - 1108
  • [37] In vitro assessment of the accuracy of digital impressions prepared using a single system for full-arch restorations on implants
    Ciocca, Leonardo
    Meneghello, Roberto
    Monaco, Carlo
    Savio, Gianpaolo
    Scheda, Lorenzo
    Gatto, Maria Rosaria
    Baldissara, Paolo
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2018, 13 (07) : 1097 - 1108
  • [38] Trueness of Extraoral Digital Impressions for Full-Arch Implant Impressions-In Vitro Study
    Sampaio-Fernandes, Manuel Antonio
    Pinto, Ricardo
    Almeida, Paulo Rocha
    Sampaio-Fernandes, Maria Margarida
    Marques, Duarte
    Figueiral, Maria Helena
    MATERIALS, 2024, 17 (12)
  • [39] Full-arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fit
    Papaspyridakos, Panos
    Hirayama, Hiroshi
    Chen, Chun-Jung
    Ho, Chung-Han
    Chronopoulos, Vasilios
    Weber, Hans-Peter
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (09) : 1099 - 1105
  • [40] The transfer accuracy of digital and conventional full-arch impressions influenced by fixed orthodontic appliances: a reference aid–based in vitro study
    Maximiliane Amelie Schlenz
    Katharina Klaus
    Alexander Schmidt
    Bernd Wöstmann
    Marco Mersmann
    Sabine Ruf
    Niko Christian Bock
    Clinical Oral Investigations, 2023, 27 : 273 - 283