Comparison of the accuracy between full-arch digital scans and scannable impression materials: an in vitro study

被引:3
|
作者
Grande, Francesco [1 ,2 ,3 ]
Celeghin, Giordano [1 ]
Gallinaro, Federica [1 ]
Mobilio, Nicola [1 ]
Catapano, Santo [1 ]
机构
[1] Univ Ferrara, Dept Prosthodont, Ferrara, Italy
[2] Polytech Univ Turin, Dept Mech & Aerosp Engn, Turin, Italy
[3] Univ Ferrara, Dept Prosthodont, Via Luigi Borsari 46, I-44121 Ferrara, Italy
关键词
Dental impression materials; Dental arch; Dimensional measurement accuracy; CONVENTIONAL IMPRESSIONS; DENTAL IMPRESSIONS; MARGINAL FIT; RESTORATIONS; PRECISION; DIGITIZATION; TRUENESS; PATIENT;
D O I
10.23736/S2724-6329.23.04766-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BACKGROUND: In some clinical cases, full-arch impression could be difficult to take correctly with the digital way. Patients with high flow salivary rate or with difficulties in mouth opening can still benefit from a conventional impression with elastomer materials that can be directly or indirectly digitized. The aim of this study was to compare the accuracy and precision of two different intraoral scanners (IOSs) and an impression material with scannable properties, by means of three-dimensional analysis of a complete dental arch. METHODS: An anatomical model of complete upper arch, modified with a Scan body placed in the retroincisive area, was used. It was firstly scanned by a desktop scanner to create a digital reference model. Then, 3 groups were created, each constituted by 5 samples. In the first group, 5 impressions were taken from the same master model with the scan-nable PVS material (Hydrorise Implant), 5 scans were taken using Trios4 (3Shape) and other 5 scans with iTero Element 5D (iTero). STL files obtained from IOSs, and scanned impressions were three-dimensionally superimposed on the STL file of the reference model using the Scan body geometry. RESULTS: The ANOVA Test (P<0.005) did not show any statistically significant difference between the accuracy and precision values of the groups. Each group shows clinically acceptable deviations from the reference model. CONCLUSIONS: Scannable polyvinylsiloxane impression materials are equally accurate and precise as the two IOSs tested in full-arch dentate impressions.
引用
收藏
页码:168 / 175
页数:8
相关论文
共 50 条
  • [21] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Mangano, Francesco Guido
    Admakin, Oleg
    Bonacina, Matteo
    Lerner, Henriette
    Rutkunas, Vygandas
    Mangano, Carlo
    BMC ORAL HEALTH, 2020, 20 (01)
  • [22] Trueness of 12 intraoral scanners in the full-arch implant impression: a comparative in vitro study
    Francesco Guido Mangano
    Oleg Admakin
    Matteo Bonacina
    Henriette Lerner
    Vygandas Rutkunas
    Carlo Mangano
    BMC Oral Health, 20
  • [23] In Vitro Accuracy of Digital and Conventional Impressions for Full-Arch Implant-Supported Prostheses
    D'haese, Rani
    Vrombaut, Tom
    Roeykens, Herman
    Vandeweghe, Stefan
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (03)
  • [24] Accuracy of a novel stereophotogrammetry system for full-arch digital implant impressions: An in vitro study and clinical case
    Ye, Yuping
    Gu, Feifei
    Liang, Jixin
    Han, Juncheng
    Tang, Zhenzhong
    Song, Zhan
    MEASUREMENT, 2024, 244
  • [25] Effect of auxiliary geometric devices on the accuracy of intraoral scans in full-arch implant-supported rehabilitations: An in vitro study
    Canullo, Luigi
    Pesce, Paolo
    Caponio, Vito Carlo Alberto
    Iacono, Roberta
    Raffone, Carlo
    Luciani, Francesco Saverio
    Menini, Maria
    JOURNAL OF DENTISTRY, 2024, 145
  • [26] Accuracy of Full-Arch Intraoral Scans Versus Conventional Impression: A Systematic Review with a Meta-Analysis and a Proposal to Standardise the Analysis of the Accuracy
    Pesce, Paolo
    Nicolini, Paolo
    Caponio, Vito Carlo Alberto
    Zecca, Piero Antonio
    Canullo, Luigi
    Isola, Gaetano
    Baldi, Domenico
    De Angelis, Nicola
    Menini, Maria
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (01)
  • [27] Influence of scan pattern on full-arch scans with three digital scanners
    Wagner, M. W.
    Vukovic, M. A.
    Grimm, W. D.
    JOURNAL OF OSSEOINTEGRATION, 2024, 16 (02) : 81 - 86
  • [28] Comparison of Milled Full-Arch Implant-Supported Frameworks Realised with a Full Digital Workflow or from Conventional Impression: A Clinical Study
    Pera, Francesco
    Pesce, Paolo
    Bagnasco, Francesco
    Pancini, Nicolo
    Carossa, Massimo
    Baldelli, Lorenzo
    Annunziata, Marco
    Migliorati, Marco
    Baldi, Domenico
    Menini, Maria
    MATERIALS, 2023, 16 (02)
  • [29] Trueness of full-arch dental models obtained by digital and conventional impression techniques: an in vivo study
    Yonca Onbasi
    Sabrin Abu-Hossin
    Maria Paulig
    Lara Berger
    Manfred Wichmann
    Ragai-Edward Matta
    Scientific Reports, 12 (1)
  • [30] Accuracy of Digital and Conventional Full-Arch Impressions in Patients: An Update
    Schmidt, Alexander
    Klussmann, Leona
    Woestmann, Bernd
    Schlenz, Maximiliane Amelie