A content-aware chatbot based on GPT 4 provides trustworthy recommendations for Cone-Beam CT guidelines in dental imaging

被引:4
|
作者
Russe, Maximilian Frederik [1 ]
Rau, Alexander [1 ,2 ]
Ermer, Michael Andreas [3 ]
Rothweiler, Rene [3 ]
Wenger, Sina [3 ]
Kloeble, Klara [3 ]
Schulze, Ralf K. W. [4 ]
Bamberg, Fabian [1 ]
Schmelzeisen, Rainer [3 ]
Reisert, Marco [5 ,6 ]
Semper-Hogg, Wiebke [3 ]
机构
[1] Univ Freiburg, Fac Med, Med Ctr, Dept Diagnost & Intervent Radiol, D-79106 Freiburg, Germany
[2] Univ Freiburg, Fac Med, Med Ctr, Dept Neuroradiol, D-79106 Freiburg, Germany
[3] Univ Freiburg, Fac Med, Med Ctr, Dept Oral & Maxillofacial Surg, Breisacher Str 64, D-79106 Freiburg, Germany
[4] Univ Bern, Sch Dent Med, Dept Oral Surg & Stomatol & Oral Diagnost, Div Oral Diagnost Sci, CH-3010 Bern, Switzerland
[5] Univ Freiburg, Dept Diagnost & Intervent Radiol, Div Med Phys, Med Ctr,Fac Med, D-79106 Freiburg, Germany
[6] Univ Freiburg, Fac Med, Med Ctr, Dept Stereotact & Funct Neurosurg, D-79106 Freiburg, Germany
关键词
Cone-Beam CT; dental imaging; natural language processing; chatbot;
D O I
10.1093/dmfr/twad015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To develop a content-aware chatbot based on GPT-3.5-Turbo and GPT-4 with specialized knowledge on the German S2 Cone-Beam CT (CBCT) dental imaging guideline and to compare the performance against humans.Methods The LlamaIndex software library was used to integrate the guideline context into the chatbots. Based on the CBCT S2 guideline, 40 questions were posed to content-aware chatbots and early career and senior practitioners with different levels of experience served as reference. The chatbots' performance was compared in terms of recommendation accuracy and explanation quality. Chi-square test and one-tailed Wilcoxon signed rank test evaluated accuracy and explanation quality, respectively.Results The GPT-4 based chatbot provided 100% correct recommendations and superior explanation quality compared to the one based on GPT3.5-Turbo (87.5% vs. 57.5% for GPT-3.5-Turbo; P = .003). Moreover, it outperformed early career practitioners in correct answers (P = .002 and P = .032) and earned higher trust than the chatbot using GPT-3.5-Turbo (P = 0.006).Conclusions A content-aware chatbot using GPT-4 reliably provided recommendations according to current consensus guidelines. The responses were deemed trustworthy and transparent, and therefore facilitate the integration of artificial intelligence into clinical decision-making.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 50 条
  • [21] Comparison of propagation-based CT using synchrotron radiation and conventional cone-beam CT for breast imaging
    Taba, Seyedamir Tavakoli
    Baran, Patrycja
    Nesterets, Yakov I.
    Pacile, Serena
    Wienbeck, Susanne
    Dullin, Christian
    Pavlov, Konstantin
    Maksimenko, Anton
    Lockie, Darren
    Mayo, Sheridan C.
    Quiney, Harry M.
    Dreossi, Diego
    Arfelli, Fulvia
    Tromba, Giuliana
    Lewis, Sarah
    Gureyev, Timur E.
    Brennan, Patrick C.
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 2740 - 2750
  • [22] A 3D imaging system for dental imaging based on digital tomosynthesis and cone beam CT
    Badea, C
    Kolitsi, Z
    Pallikarakis, N
    MEDICON 2001: PROCEEDINGS OF THE INTERNATIONAL FEDERATION FOR MEDICAL & BIOLOGICAL ENGINEERING, PTS 1 AND 2, 2001, : 739 - 741
  • [23] Development of the 4D Cone-Beam CT Modelling Software to Investigate Effects of Imaging Parameters
    Kim, D.
    Kim, T.
    Kang, S.
    Suh, T.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Metal Artifact Reduction based on 2D-Projection Correction for Dental Cone-beam CT Images
    Narkbuakaew, Walita
    Aootaphao, Sorapong
    Thanasupsombat, Chalinee
    Thongvigitmanee, Saowapak S.
    13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,
  • [25] Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation
    Ning, R
    Chen, B
    Yu, RF
    Conover, D
    Tang, XY
    Ning, Y
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) : 949 - 963
  • [26] Compressed Sensing based Image Reconstruction with Projection Recovery for Limited Angle Cone-Beam CT Imaging
    Xie, Shoulie
    Huang, Weimin
    Yang, Tao
    Wu, Dajun
    Liu, Huiying
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 1307 - 1310
  • [27] Flat panel detector-based cone-beam volume CT breast imaging: detector evaluation
    Yu, Y
    Conover, D
    Ning, RL
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 711 - 719
  • [28] Cone-beam CT imaging with laterally enlarged field of view based on independently movable source and detector
    Karius, Andre
    Szkitsak, Juliane
    Strnad, Vratislav
    Fietkau, Rainer
    Bert, Christoph
    MEDICAL PHYSICS, 2023, 50 (08) : 5135 - 5149
  • [29] Evaluation of gantry speed on image quality and imaging dose for 4D cone-beam CT acquisition
    Santoso, Andrew P.
    Song, Kwang H.
    Qin, Yujiao
    Gardner, Stephen J.
    Liu, Chang
    Chetty, Indrin J.
    Movsas, Benjamin
    Ajlouni, Munther
    Wen, Ning
    RADIATION ONCOLOGY, 2016, 11
  • [30] Evaluation of gantry speed on image quality and imaging dose for 4D cone-beam CT acquisition
    Andrew P. Santoso
    Kwang H. Song
    Yujiao Qin
    Stephen J. Gardner
    Chang Liu
    Indrin J. Chetty
    Benjamin Movsas
    Munther Ajlouni
    Ning Wen
    Radiation Oncology, 11