Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation

被引:128
|
作者
Ning, R [1 ]
Chen, B [1 ]
Yu, RF [1 ]
Conover, D [1 ]
Tang, XY [1 ]
Ning, Y [1 ]
机构
[1] Univ Rochester, Dept Radiol & Elect & Comp Engn, Rochester, NY 14642 USA
关键词
angiography; cone-beam reconstruction; flat panel detector; spiral computed tomography (CT); volume computed tomography (CT);
D O I
10.1109/42.887842
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Preliminary evaluation of recently developed large-area flat panel detectors (FPDs) indicates that FPDs have some potential advantages: compactness, absence of geometric distortion and veiling glare with the benefits of high resolution, high detective quantum efficiency (DQE), high frame rate and high dynamic range, small image lag (<1%), and excellent linearity (similar to1%). The advantages of the new FPD make it a promising candidate for cone-beam volume computed tomography (CT) angiography (CBVCTA) imaging. The purpose of this study is to characterize a prototype FPD-based imaging system for CBVCTA applications. A prototype FPD-based CBVCTA imaging system has been designed and constructed around a modified GE 8800 CT scanner. This system is evaluated for a CBVCTA imaging task in the head and neck using four phantoms and a frozen rat. The system is first characterized in terms of linearity and dynamic range of the detector. Then, the optimal selection of kVps for CBVCTA is determined and the effect of image lag and scatter on the image quality of the CBVCTA system is evaluated. Next, low-contrast resolution and high-contrast spatial resolution are measured. Finally, the example reconstruction images of a frozen rat are presented. The results indicate that the FPD-based CBVCT can achieve 2.75-1p/mm spatial resolution at 0% modulation transfer function (MTF) and provide more than enough low-contrast resolution for intravenous CBVCTA imaging in the head and neck with clinically acceptable entrance exposure level. The results also suggest that to use an FPD for large cone-angle applications, such as body angiography, further investigations are required.
引用
收藏
页码:949 / 963
页数:15
相关论文
共 50 条
  • [1] Flat panel detector-based cone-beam volume CT breast imaging: detector evaluation
    Yu, Y
    Conover, D
    Ning, RL
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 711 - 719
  • [2] Flat panel detector-based cone beam volume CT imaging: detector evaluation
    Ning, R
    Tang, XY
    Yu, RF
    Conover, D
    Zhang, DH
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 192 - 203
  • [3] Flat panel detector-based cone beam volume CT imaging
    Ning, R
    MEDICAL PHYSICS, 2003, 30 (06) : 1370 - 1370
  • [4] Flat panel detector-based cone beam CT imaging: Preliminary system evaluation
    Ning, RL
    Conover, D
    Yu, Y
    Lu, XH
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 616 - 620
  • [5] Flat panel detector-based cone beam CT for dynamic imaging: System evaluation
    Ning, Ruola
    Conover, David
    Yu, Yong
    Zhang, Yan
    Cai, Weixing
    Yang, Dong
    Lu, Xianghua
    MEDICAL IMAGING 2006: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2006, 6142
  • [6] Flat panel detector-based cone beam CT lung imaging: preliminary system evaluation
    Ning, R
    Conover, D
    Yu, Y
    Cai, WX
    Lu, XH
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 147 - 158
  • [7] Flat panel detector-based volume tomographic angiography imaging: Detector evaluation
    Ning, R
    Zhang, DH
    Chen, B
    Conover, D
    Yu, RF
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 167 - 178
  • [8] Flat panel detector-based cone beam volume CT breast imaging: Phantom study
    Ning, R
    Chen, B
    Conover, D
    McHugh, L
    Cullinan, JA
    Robinson, AE
    RADIOLOGY, 2001, 221 : 544 - 544
  • [9] Preliminary system characterization of flat panel detector-based cone beam CT for breast imaging
    Ning, RL
    Yu, Y
    Conover, D
    Lu, XH
    He, HG
    Chen, ZK
    Schiffhauer, L
    Cullinan, J
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 292 - 303
  • [10] Flat panel detector-based cone beam volume CT breast imaging: preliminary phantom study
    Ning, RL
    Chen, BA
    Conover, D
    McHugh, L
    Cullinan, J
    Yu, RF
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 601 - 610