Flat panel detector-based cone-beam volume CT angiography imaging: System evaluation

被引:128
|
作者
Ning, R [1 ]
Chen, B [1 ]
Yu, RF [1 ]
Conover, D [1 ]
Tang, XY [1 ]
Ning, Y [1 ]
机构
[1] Univ Rochester, Dept Radiol & Elect & Comp Engn, Rochester, NY 14642 USA
关键词
angiography; cone-beam reconstruction; flat panel detector; spiral computed tomography (CT); volume computed tomography (CT);
D O I
10.1109/42.887842
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Preliminary evaluation of recently developed large-area flat panel detectors (FPDs) indicates that FPDs have some potential advantages: compactness, absence of geometric distortion and veiling glare with the benefits of high resolution, high detective quantum efficiency (DQE), high frame rate and high dynamic range, small image lag (<1%), and excellent linearity (similar to1%). The advantages of the new FPD make it a promising candidate for cone-beam volume computed tomography (CT) angiography (CBVCTA) imaging. The purpose of this study is to characterize a prototype FPD-based imaging system for CBVCTA applications. A prototype FPD-based CBVCTA imaging system has been designed and constructed around a modified GE 8800 CT scanner. This system is evaluated for a CBVCTA imaging task in the head and neck using four phantoms and a frozen rat. The system is first characterized in terms of linearity and dynamic range of the detector. Then, the optimal selection of kVps for CBVCTA is determined and the effect of image lag and scatter on the image quality of the CBVCTA system is evaluated. Next, low-contrast resolution and high-contrast spatial resolution are measured. Finally, the example reconstruction images of a frozen rat are presented. The results indicate that the FPD-based CBVCT can achieve 2.75-1p/mm spatial resolution at 0% modulation transfer function (MTF) and provide more than enough low-contrast resolution for intravenous CBVCTA imaging in the head and neck with clinically acceptable entrance exposure level. The results also suggest that to use an FPD for large cone-angle applications, such as body angiography, further investigations are required.
引用
收藏
页码:949 / 963
页数:15
相关论文
共 50 条
  • [31] Usefulness of cone-beam volume CT with flat panel detectors in conjunction with catheter angiography for transcatheter arterial embolization
    Kakeda, Shingo
    Korogi, Yukunori
    Ohnari, Norihiro
    Moriya, Junji
    Oda, Nobuhiro
    Nishino, Kazuyoshi
    Miyamoto, Wataru
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (12) : 1508 - 1516
  • [32] Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT
    Bian, Junguo
    Siewerdsen, Jeffrey H.
    Han, Xiao
    Sidky, Emil Y.
    Prince, Jerry L.
    Pelizzari, Charles A.
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (22): : 6575 - 6599
  • [33] Image quality of flat panel cone-beam CT
    Rose, G
    Wiegert, J
    Schäfer, D
    Fiedler, K
    Conrads, N
    Timmer, J
    Rasche, V
    Noordhoek, N
    Klotz, E
    Koppe, R
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 677 - 683
  • [34] Examination of the dental cone-beam CT equipped with flat-panel-detector (FPD)
    Ito, Rieko
    Fujita, Naotoshi
    Kodera, Yoshie
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [35] Iterative Reconstruction for Circular Cone-Beam CT with an Offset Flat-Panel Detector
    Hansis, Eberhard
    Bredno, Joerg
    Sowards-Emmerd, David
    Shao, Lingxiong
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2228 - 2231
  • [36] Noise, sampling, and the number of projections in cone-beam CT with a flat-panel detector
    Zhao, Z.
    Gang, G. J.
    Siewerdsen, J. H.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [37] Image lag modeling and correction method for flat panel detector in cone-beam CT
    Huang Kui-Dong
    Zhang Ding-Hua
    Li Ming-Jun
    Zhang Hua
    ACTA PHYSICA SINICA, 2013, 62 (21)
  • [38] Rhinolithiasis: the importance of flat panel detector-based cone beam computed tomography in diagnosis and treatment
    Sumbullu, M. Akif
    Tozoglu, Ummuhan
    Yoruk, Ozgur
    Yilmaz, A. Berhan
    Ucuncu, Harun
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (06): : E65 - E67
  • [39] Evaluation of flat panel detector cone beam CT breast imaging with different sizes of breast phantoms
    Ning, R
    Conover, D
    Lu, XH
    Zhang, Y
    Yu, Y
    Schiffhauer, L
    Cullinan, J
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 626 - 636
  • [40] Investigation of image lag in a high-speed flat panel detector-based cone beam CT imaging system - art. no. 61420Z
    Zhang, Yan
    Ning, Ruola
    Conover, David
    Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : Z1420 - Z1420