A content-aware chatbot based on GPT 4 provides trustworthy recommendations for Cone-Beam CT guidelines in dental imaging

被引:4
|
作者
Russe, Maximilian Frederik [1 ]
Rau, Alexander [1 ,2 ]
Ermer, Michael Andreas [3 ]
Rothweiler, Rene [3 ]
Wenger, Sina [3 ]
Kloeble, Klara [3 ]
Schulze, Ralf K. W. [4 ]
Bamberg, Fabian [1 ]
Schmelzeisen, Rainer [3 ]
Reisert, Marco [5 ,6 ]
Semper-Hogg, Wiebke [3 ]
机构
[1] Univ Freiburg, Fac Med, Med Ctr, Dept Diagnost & Intervent Radiol, D-79106 Freiburg, Germany
[2] Univ Freiburg, Fac Med, Med Ctr, Dept Neuroradiol, D-79106 Freiburg, Germany
[3] Univ Freiburg, Fac Med, Med Ctr, Dept Oral & Maxillofacial Surg, Breisacher Str 64, D-79106 Freiburg, Germany
[4] Univ Bern, Sch Dent Med, Dept Oral Surg & Stomatol & Oral Diagnost, Div Oral Diagnost Sci, CH-3010 Bern, Switzerland
[5] Univ Freiburg, Dept Diagnost & Intervent Radiol, Div Med Phys, Med Ctr,Fac Med, D-79106 Freiburg, Germany
[6] Univ Freiburg, Fac Med, Med Ctr, Dept Stereotact & Funct Neurosurg, D-79106 Freiburg, Germany
关键词
Cone-Beam CT; dental imaging; natural language processing; chatbot;
D O I
10.1093/dmfr/twad015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives To develop a content-aware chatbot based on GPT-3.5-Turbo and GPT-4 with specialized knowledge on the German S2 Cone-Beam CT (CBCT) dental imaging guideline and to compare the performance against humans.Methods The LlamaIndex software library was used to integrate the guideline context into the chatbots. Based on the CBCT S2 guideline, 40 questions were posed to content-aware chatbots and early career and senior practitioners with different levels of experience served as reference. The chatbots' performance was compared in terms of recommendation accuracy and explanation quality. Chi-square test and one-tailed Wilcoxon signed rank test evaluated accuracy and explanation quality, respectively.Results The GPT-4 based chatbot provided 100% correct recommendations and superior explanation quality compared to the one based on GPT3.5-Turbo (87.5% vs. 57.5% for GPT-3.5-Turbo; P = .003). Moreover, it outperformed early career practitioners in correct answers (P = .002 and P = .032) and earned higher trust than the chatbot using GPT-3.5-Turbo (P = 0.006).Conclusions A content-aware chatbot using GPT-4 reliably provided recommendations according to current consensus guidelines. The responses were deemed trustworthy and transparent, and therefore facilitate the integration of artificial intelligence into clinical decision-making.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 50 条
  • [41] Motion compensation for cone-beam CT based on 4D motion field of sinogram tracked markers
    Schäfer, D
    Bertram, M
    Conrads, N
    Wiegert, J
    Rose, G
    Rasche, V
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 189 - 194
  • [42] In-treatment 4D cone-beam CT with image-based respiratory phase recognition
    Kida, Satoshi
    Masutani, Yoshitaka
    Yamashita, Hideomi
    Imae, Toshikazu
    Matsuura, Taeko
    Saotome, Naoya
    Ohtomo, Kuni
    Nakagawa, Keiichi
    Haga, Akihiro
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2012, 5 (02) : 138 - 147
  • [43] 4D Cone-beam CT reconstruction using a motion model based on principal component analysis
    Staub, David
    Docef, Alen
    Brock, Robert S.
    Vaman, Constantin
    Murphy, Martin J.
    MEDICAL PHYSICS, 2011, 38 (12) : 6697 - 6709
  • [44] In-treatment 4D cone-beam CT with image-based respiratory phase recognition
    Satoshi Kida
    Yoshitaka Masutani
    Hideomi Yamashita
    Toshikazu Imae
    Taeko Matsuura
    Naoya Saotome
    Kuni Ohtomo
    Keiichi Nakagawa
    Akihiro Haga
    Radiological Physics and Technology, 2012, 5 (2) : 138 - 147
  • [45] Patient-specific scatter correction for flat-panel detector-based cone-beam CT imaging
    Zhao, Wei
    Brunner, Stephen
    Niu, Kai
    Schafer, Sebastian
    Royalty, Kevin
    Chen, Guang-Hong
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (03): : 1339 - 1365
  • [46] Model-based perfusion reconstruction with time separation technique in cone-beam CT dynamic liver perfusion imaging
    Haseljic, Hana
    Frysch, Robert
    Kulvait, Vojtech
    Werncke, Thomas
    Bruesch, Inga
    Speck, Oliver
    Schulz, Jessica
    Manhart, Michael
    Rose, Georg
    MEDICAL PHYSICS, 2025,
  • [47] A Cascaded Systems Model for Imaging Performance and Task-Based Optimization in Dual-Energy Cone-Beam CT
    Gang, G.
    Prakash, P.
    Zbijewski, W.
    Stayman, J.
    Siewerdsen, J.
    MEDICAL PHYSICS, 2011, 38 (06) : 3833 - +
  • [48] Development of a 4D digital phantom for Cone-Beam CT (CBCT) imaging on the Varian On-Board Imager (OBI)
    Amin, Adam Tan Mohd
    Mokri, Siti Salasiah
    Ahmad, Rozilawati
    Abd Rahni, Ashrani Aizzuddin
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2019, 11 (03): : 90 - 99
  • [49] FAST 4D CONE-BEAM CT IMAGING USING THE DUAL SOURCE ORTHOGONAL KV SYSTEM OF THE VERO SYSTEM
    Poels, K.
    Depuydt, T.
    Verellen, D.
    De Ridder, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S183 - S183
  • [50] Evaluation of patient dose using a virtual CT scanner: Applications to 4DCT Simulation and Kilovoltage Cone-Beam Imaging
    DeMarco, J. J.
    McNitt-Gray, M. F.
    Cagnon, C. H.
    Angel, E.
    Agazaryan, N.
    Zankl, M.
    INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP, 2008, 102