Comparison between Novel Anatomical Locking Guide Plate and Conventional Locking Plate for Acetabular Fractures: A Finite Element Analysis

被引:0
|
作者
Liu, Xiao [1 ,2 ]
Gao, Jianpeng [1 ,2 ]
Wu, Xiaoyong [1 ,2 ]
Deng, Junhao [1 ,2 ]
Li, Zijian [1 ,2 ]
Li, Ran [1 ,2 ]
Zhang, Licheng [1 ,2 ]
Liu, Jianheng [1 ,2 ]
Li, Ming [1 ,2 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Orthopaed, 28 Fuxin Rd, Beijing 100853, Peoples R China
[2] Natl Clin Res Ctr Orthoped Sports Med & Rehabil, 28 Fuxin Rd, Beijing 100853, Peoples R China
来源
LIFE-BASEL | 2023年 / 13卷 / 11期
关键词
acetabulum; internal fixators; fractures; finite element analysis; ANTERIOR COLUMN; SCREW FIXATION; TRANSVERSE; CLASSIFICATION; VALIDATION; MANAGEMENT; REDUCTION; EFFICACY; PELVIS;
D O I
10.3390/life13112108
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The treatment of complex acetabular fractures remains a complicated clinical challenge. Our self-designed novel anatomical locking guide plate (NALGP) has previously shown promising potential in T-shaped acetabular fractures (TAF), but a direct comparison with conventional fixations is yet to be made. The TAF model was established based on a volunteer's computer tomography data and then fixed with double column locking plates (DLP), a posterior column locking plate with anterior column screws (LPACS), and our NALGP. Forces of 200 N, 400 N, and 600 N were then loaded on the model vertically downward, respectively. The stress distribution and peaks and maximum displacements at three sites were assessed. We found that the stress area of all three plates was mainly concentrated around the fracture line, while only the matching screws of the NALGP showed no obvious stress concentration points. In addition, the NALGP and DLP showed significantly less fracture fragment displacement than the LPACS at the three main fracture sites. The NALGP was found to have less displacement than DLP at the posterior column and ischiopubic branch sites, especially under the higher loading forces of 400 N and 600 N. The fixation stability of the NALGP for TAF was similar to that of DLP but better than that of LPACS. Moreover, the NALGP and its matching screws have a more reasonable stress distribution under different loads of force and the same strength as the LPACS.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Subtrochanteric Fractures: Comparison of Proximal Femur Locking Plate and Intramedullary Locking Nail Fixation Outcome
    Ahmadreza Mirbolook
    Babak Siavashi
    Adel Ebrahimpour Jafarinezhad
    Sina Khajeh Jahromi
    Maral Farahmand
    Melina Roohi Rad
    Mohammad Amin Kahe
    Indian Journal of Surgery, 2015, 77 : 795 - 798
  • [42] Subtrochanteric Fractures: Comparison of Proximal Femur Locking Plate and Intramedullary Locking Nail Fixation Outcome
    Mirbolook, Ahmadreza
    Siavashi, Babak
    Jafarinezhad, Adel Ebrahimpour
    Jahromi, Sina Khajeh
    Farahmand, Maral
    Rad, Melina Roohi
    Kahe, Mohammad Amin
    INDIAN JOURNAL OF SURGERY, 2015, 77 : S795 - S798
  • [43] Biomechanical Properties of 3-Dimensional Printed Volar Locking Distal Radius Plate: Comparison With Conventional Volar Locking Plate
    Kim, Sung-Jae
    Jo, Young-Hoon
    Choi, Wan-Sun
    Lee, Chang-Hun
    Lee, Bong-Gun
    Kim, Joo-Hak
    Lee, Kwang-Hyun
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2017, 42 (09): : 747.e1 - 747.e6
  • [44] Longitudinally centered embossed structure in the locking compression plate for biodegradable bone implant plate: a finite element analysis
    Chandra, Girish
    Pandey, Ajay
    Tipan, Nilesh
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2022, 25 (06) : 603 - 618
  • [45] A biomechanical comparison between two volar locking plate systems for distal radius fractures
    Chen, Li
    Dai, Qiang
    Wongworawat, Montri D.
    ORTHOPEDICS, 2006, 29 (10) : 927 - 929
  • [46] BIOMECHANICAL EVALUATION OF LOCKING COMPRESSION PLATE (LCP) VERSUS DYNAMIC COMPRESSION PLATE (DCP): A FINITE ELEMENT ANALYSIS
    Suaimi, Muhammad Khairul Asyraf
    Ab Rashid, Amir Mustakim
    Nasution, Ahmad Kafrawi
    Seng, Gan Hong
    Kadir, Mohammed Rafiq Abdul
    Ramlee, Muhammad Hanif
    JURNAL TEKNOLOGI-SCIENCES & ENGINEERING, 2022, 84 (03): : 125 - 131
  • [47] Design improvements to enhance mechanical performance of a locking compression plate as a biodegradable implant plate: a finite element analysis
    Singh, Gourav
    Pandey, Ajay
    Journal of Medical Engineering and Technology, 2024, 48 (05): : 186 - 206
  • [48] Single column locking plate fixation is inadequate in two column acetabular fractures. A biomechanical analysis
    Kiarash Khajavi
    Arthur T Lee
    Derek P Lindsey
    Philipp Leucht
    Michael J Bellino
    Nicholas J Giori
    Journal of Orthopaedic Surgery and Research, 5
  • [49] Single column locking plate fixation is inadequate in two column acetabular fractures. A biomechanical analysis
    Khajavi, Kiarash
    Lee, Arthur T.
    Lindsey, Derek P.
    Leucht, Philipp
    Bellino, Michael J.
    Giori, Nicholas J.
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2010, 5
  • [50] Locking Compression Plate Fixation of Feline Acetabular Fractures: Application, Complications and Perioperative Outcome
    Murugarren, Maider
    Piana, Francesco
    Kalff, Stephen
    Solano, Miguel
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2023, 36 (02) : 93 - 98