Comparison between Novel Anatomical Locking Guide Plate and Conventional Locking Plate for Acetabular Fractures: A Finite Element Analysis

被引:0
|
作者
Liu, Xiao [1 ,2 ]
Gao, Jianpeng [1 ,2 ]
Wu, Xiaoyong [1 ,2 ]
Deng, Junhao [1 ,2 ]
Li, Zijian [1 ,2 ]
Li, Ran [1 ,2 ]
Zhang, Licheng [1 ,2 ]
Liu, Jianheng [1 ,2 ]
Li, Ming [1 ,2 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Orthopaed, 28 Fuxin Rd, Beijing 100853, Peoples R China
[2] Natl Clin Res Ctr Orthoped Sports Med & Rehabil, 28 Fuxin Rd, Beijing 100853, Peoples R China
来源
LIFE-BASEL | 2023年 / 13卷 / 11期
关键词
acetabulum; internal fixators; fractures; finite element analysis; ANTERIOR COLUMN; SCREW FIXATION; TRANSVERSE; CLASSIFICATION; VALIDATION; MANAGEMENT; REDUCTION; EFFICACY; PELVIS;
D O I
10.3390/life13112108
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The treatment of complex acetabular fractures remains a complicated clinical challenge. Our self-designed novel anatomical locking guide plate (NALGP) has previously shown promising potential in T-shaped acetabular fractures (TAF), but a direct comparison with conventional fixations is yet to be made. The TAF model was established based on a volunteer's computer tomography data and then fixed with double column locking plates (DLP), a posterior column locking plate with anterior column screws (LPACS), and our NALGP. Forces of 200 N, 400 N, and 600 N were then loaded on the model vertically downward, respectively. The stress distribution and peaks and maximum displacements at three sites were assessed. We found that the stress area of all three plates was mainly concentrated around the fracture line, while only the matching screws of the NALGP showed no obvious stress concentration points. In addition, the NALGP and DLP showed significantly less fracture fragment displacement than the LPACS at the three main fracture sites. The NALGP was found to have less displacement than DLP at the posterior column and ischiopubic branch sites, especially under the higher loading forces of 400 N and 600 N. The fixation stability of the NALGP for TAF was similar to that of DLP but better than that of LPACS. Moreover, the NALGP and its matching screws have a more reasonable stress distribution under different loads of force and the same strength as the LPACS.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Interfragmentary lag screw and locking plate combination in simple distal femoral fractures: A finite element analysis
    Zhang, Jun
    Wei, Yan
    Li, Guoding
    Wang, Jian
    Xu, Youjia
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2021, 55 (01) : 9 - 15
  • [32] Locking Compression Pilon Plate for Fixation of Comminuted Posterior Wall Acetabular Fractures: A Novel Technique
    Lee, Adam K.
    Wagner, Benjamin R.
    McPhillips, Kristin
    Horwitz, Daniel S.
    Widmaier, James C., Jr.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (01) : E32 - E36
  • [33] Biomechanical comparison between low profile 2.7 mm distal locking hook plate and 3.5 mm distal locking hook plate for acromioclavicular joint injury: A finite element analysis
    Lee, Jeong-Woo
    Song, Min-Jun
    Lee, Sung-Jae
    Song, Hyun Seok
    Jung, Youn-Sung
    Kim, Hyungsuk
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2024, 55 (10):
  • [34] A Novel Locking Buttress Plate Designed for Simultaneous Medial and Posterolateral Tibial Plateau Fractures: Concept and Comparative Finite Element Analysis
    Yan, Bangji
    Huang, Xiaotao
    Xu, Yingxing
    Zou, Chengshi
    ORTHOPAEDIC SURGERY, 2023, 15 (04) : 1104 - 1116
  • [35] A biomechanical comparison of locking plate and locking nail implants used for fractures of the proximal humerus
    Kitson, Jeffrey
    Booth, Grant
    Day, Robert
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2007, 16 (03) : 362 - 366
  • [36] Operative Treatment of Clavicle Midshaft Fractures: Comparison between Reconstruction Plate and Reconstruction Locking Compression Plate
    Cho, Chul-Hyun
    Song, Kwang-Soon
    Min, Byung-Woo
    Bae, Ki-Cheor
    Lee, Kyung-Jae
    CLINICS IN ORTHOPEDIC SURGERY, 2010, 2 (03) : 154 - 159
  • [37] LOCKING EFFECTS IN THE FINITE-ELEMENT APPROXIMATION OF PLATE MODELS
    SURI, M
    BABUSKA, I
    SCHWAB, C
    MATHEMATICS OF COMPUTATION, 1995, 64 (210) : 461 - 482
  • [38] Outcome After Treatment of Distal Fibula Fractures Using One-Third Tubular Plate, Locking Compression Plate or Distal Anatomical Locking Compression Plate
    Jensen, Thomas Giver
    Almadareb, Mostafa Aqeel Khudhair
    Nielsen, Maria Booth
    Hansen, Emil Jesper
    Lindberg-Larsen, Martin
    JOURNAL OF FOOT & ANKLE SURGERY, 2023, 62 (03): : 524 - 528
  • [39] Finite element method analysis of bone stress for variants of locking plate placement
    Palka, Marek
    Miszczyk, Patrycja
    Jurewicz, Maciej
    Perz, Rafal
    HELIYON, 2024, 10 (08)
  • [40] Biomechanical comparison of conventional and optimised locking plates for the fixation of intraarticular calcaneal fractures: a finite element analysis
    Ouyang, Hanbin
    Deng, Yuping
    Xie, Pusheng
    Yang, Yang
    Jiang, Bingyun
    Zeng, Canjun
    Huang, Wenhua
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (12) : 1339 - 1349