A Novel Locking Buttress Plate Designed for Simultaneous Medial and Posterolateral Tibial Plateau Fractures: Concept and Comparative Finite Element Analysis

被引:4
|
作者
Yan, Bangji [1 ]
Huang, Xiaotao [1 ,4 ]
Xu, Yingxing [2 ]
Zou, Chengshi [3 ]
机构
[1] Cixi Hosp Tradit Chinese Med, Dept Orthopaed & Traumatol, Ningbo, Peoples R China
[2] Kunming Med Univ, Affiliated Hosp 1, Dept Trauma Ctr, Kunming, Peoples R China
[3] Cixi Hosp Tradit Chinese Med, Dept Radiol, Ningbo, Peoples R China
[4] Cixi Hosp Tradit Chinese Med, Dept Orthopaed & Traumatol, Ningbo 315300, Zhejiang, Peoples R China
关键词
Biomechanics; Finite Element Analysis; Fixation; Locking Buttress Plate; Tibial Plateau Fracture; FIXATION;
D O I
10.1111/os.13660
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: The complex tibial plateau fractures involving both medial and posterolateral columns are of frequent occurrence in clinics, but the existing fixation system cannot deal with medial and posterolateral fragments simultaneously. Therefore, a novel locking buttress plate named as medial and posterior column plate (MPCP) was designed in this study to fix the simultaneous medial and posterolateral tibial plateau fractures. Meanwhile, the comparative finite element analysis (FEA) was conducted to investigate the discrepancy between MPCP and traditional multiple plates (MP + PLP) in their biomechanical characteristics.Methods: Two 3D finite element models of simultaneous medial and posterolateral tibial plateau fracture fixed with MPCP and MP + PLP system, respectively, was constructed. To imitate the axial stress of knee joint in ordinary life, diverse axial forces with 100, 500, 1000, and 1500 N were applied in the two fixation models, and then the equivalent displacement and stress nephograms and values were obtained.Results: The similar trend of displacement and stress increasing with the loads was observed in the two fixation models. However, several heterogeneities of displacement and stress distribution were found in the two fixation models. The max displacement and von Mises stress values of plates, screws, and fragments in the MPCP fixation model were significantly smaller than that in the MP + PLP fixation model, except for the max-shear stress values.Conclusion: As a single locking buttress plate, the MPCP system showed the excellent benefit on improving the stability of the simultaneous medial and posterolateral tibial plateau fractures, compared with the traditional double plate fixation system. However, the excessive shear stress around screw holes should be paid attention to prevent trabecular microfracture and screw loosening.
引用
收藏
页码:1104 / 1116
页数:13
相关论文
共 50 条
  • [1] Newly designed plate for the treatment of posterolateral tibial plateau fractures: a finite element analysis
    Zhaokui Yan
    Chang Zou
    Guy Romeo Kenmegne
    Xuelin Pan
    Nawin Ghimire
    Kuruwitage Manthi Nihara Silva
    Yue Fang
    Journal of Orthopaedic Surgery and Research, 19
  • [2] Newly designed plate for the treatment of posterolateral tibial plateau fractures: a finite element analysis
    Yan, Zhaokui
    Zou, Chang
    Kenmegne, Guy Romeo
    Pan, Xuelin
    Ghimire, Nawin
    Silva, Kuruwitage Manthi Nihara
    Fang, Yue
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [3] Biomechanics and finite element analysis of a novel plate designed for posterolateral tibial plateau fractures via the anterolateral approach
    Zhang, CongMing
    Bai, HuanAn
    Ma, Teng
    Liu, Lu
    Li, Zhong
    Zhang, Kun
    Huang, Qiang
    Wang, Qian
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [4] Biomechanics and finite element analysis of a novel plate designed for posterolateral tibial plateau fractures via the anterolateral approach
    CongMing Zhang
    HuanAn Bai
    Teng Ma
    Lu Liu
    Zhong Li
    Kun Zhang
    Qiang Huang
    Qian Wang
    Scientific Reports, 13
  • [5] Finite element analysis of a novel anatomical plate in posterolateral plateau fractures
    Jian, Zhen
    Jiang, Xinhua
    Li, Dejian
    Zhou, Jianhua
    Yu, Baoqing
    Yi, Chengqing
    FRONTIERS IN SURGERY, 2024, 11
  • [6] Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study
    Pengbo Chen
    Hua Lu
    Hao Shen
    Wei Wang
    Binbin Ni
    Jishizhan Chen
    Journal of Orthopaedic Surgery and Research, 12
  • [7] Newly designed anterolateral and posterolateral locking anatomic plates for lateral tibial plateau fractures: a finite element study
    Chen, Pengbo
    Lu, Hua
    Shen, Hao
    Wang, Wei
    Ni, Binbin
    Chen, Jishizhan
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2017, 12
  • [8] A new anatomic locking plate for the treatment of posterolateral tibial plateau fractures
    Jian, Zhen
    Ao, Rongguang
    Zhou, Jianhua
    Jiang, Xinhua
    Zhang, Dianying
    Yu, Baoqing
    BMC MUSCULOSKELETAL DISORDERS, 2018, 19
  • [9] A new anatomic locking plate for the treatment of posterolateral tibial plateau fractures
    Zhen Jian
    Rongguang Ao
    Jianhua Zhou
    Xinhua Jiang
    Dianying Zhang
    Baoqing Yu
    BMC Musculoskeletal Disorders, 19
  • [10] Posterolateral tibial plateau fractures, how to buttress? Reversed L posteromedial or the posterolateral approach: a comparative cadaveric study
    Wich Orapiriyakul
    Theerachai Apivatthakakul
    Chanakarn Phornphutkul
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 505 - 513